Simple separation and characterization of lanthanide-polyaminocarboxylic acid complexes by HILIC ESI-MS

被引:10
|
作者
Beuvier, L. [1 ,3 ]
Bresson, C. [1 ]
Nonell, A. [1 ]
Vio, L. [1 ]
Henry, N. [2 ]
Pichon, V. [2 ,3 ]
Chartier, F. [4 ]
机构
[1] CEA, Lab Dev Analyt Nucl Isotop & Elementaire, SEARS, DEN,DPC, F-91191 Gif Sur Yvette, France
[2] PSL Res Univ, ESPCI ParisTech, Lab Sci Analyt Bioanalyt & Miniaturisat, CNRS ESPCI Paris Tech,UMR CBI 8231, F-75231 Paris 05, France
[3] Univ Paris 04, UPMC, F-75005 Paris, France
[4] CEA, DEN, Dept Chim Phys, F-91191 Gif Sur Yvette, France
关键词
INTERACTION LIQUID-CHROMATOGRAPHY; HYDROPHILIC-INTERACTION CHROMATOGRAPHY; IONIZATION MASS-SPECTROMETRY; IMAGING CONTRAST AGENTS; SPECIATION ANALYSIS; INTERACTION LC; HUMAN SERUM; ICP-MS; GADOLINIUM; PLASMA;
D O I
10.1039/c5ra16078b
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
The separation and characterization of lanthanide (Ln) complexes bearing ethylenediaminetetraacetic acid (EDTA) and diethylenetriaminepentaacetic acid (DTPA), species of concern in advanced nuclear fuel treatment processes, were investigated by hydrophilic interaction liquid chromatography (HILIC) coupled with electrospray ionization mass spectrometry (ESI-MS). Selectivity properties of stationary phases with different polar functions (cross-linked diol, cyano, zwitterionic and amide) towards the Ln (Er, Eu, Gd, Nd)-EDTA/DTPA complexes were assessed. Only amide bonded stationary phases allowed simple separation of the complexes in isocratic mode, while the other stationary phases did not provide sufficient selectivity, leading to the co-elution of the complexes whatever the mobile phase composition. The chromatographic properties of two amide-based columns with different surface characteristics (XBridge and TSK Gel) were probed with a set of lanthanide complexes under identical conditions. The column giving the best performances was selected for further retention mechanism study. The effect of several parameters, such as the acetonitrile (ACN) content (40-80%) and ammonium acetate concentration (5-20 mmol L-1) was studied on the retention of the lanthanide complexes. The results showed that electrostatic interactions did not significantly affect their elution, while the adsorption mechanism was found to be predominant for ACN percentages higher than 55%. In the final step, faster HPLC conditions were applied by using an amide column packed with sub-2 mm particles (Acquity). More efficient separation of the lanthanide complexes, and decreases in analysis time, solvent consumption and generated effluent volumes, were obtained. Such an approach could lead to the development of greener analytical methods than conventional chromatographic separations, which is of prime concern for the study of radioactive samples.
引用
收藏
页码:92858 / 92868
页数:11
相关论文
共 50 条
  • [21] CZE and ESI-MS of Borate-Sugar Complexes
    Quirino, Joselito P.
    CHROMATOGRAPHIA, 2010, 72 (5-6) : 503 - 510
  • [22] Characterization of crystal content by ESI-MS and MALDI-MS
    Potier, N
    Lamour, V
    Poterszman, A
    Thierry, JC
    Moras, D
    Van Dorsselaer, A
    ACTA CRYSTALLOGRAPHICA SECTION D-STRUCTURAL BIOLOGY, 2000, 56 : 1583 - 1590
  • [23] LC–DAD–ESI-MS–MS Separation and Chemical Characterization of the Inflammatory Fraction of the Roots of Euphorbia kansui
    Li Zhang
    Xiaoyun Shu
    Anwei Ding
    Li Yu
    Yuping Tang
    Jin-ao Duan
    Erxin Shang
    Xiangchun Shen
    Chromatographia, 2009, 70 : 805 - 810
  • [24] Simple Preparation of Various Types of Mixtures of Luminescent β-Diketonato Europium (III) Complexes for ESI-MS/MS Identification
    Kurata, Shoji
    Sakurai, Takao
    BUNSEKI KAGAKU, 2015, 64 (09) : 695 - 703
  • [25] Characterization of Chemical Species in Lanthanide (III)-Alizarin Complexone (ALC)-Fluoride Solution Using ESI-MS
    Yamashita, Kazuko
    Nakada, Tatsuo
    Kawasaki, Hideya
    Arakawa, Ryuichi
    BUNSEKI KAGAKU, 2016, 65 (01) : 39 - 43
  • [26] ESI-MS assay for the rapid characterization of carbohydrate polymerizing
    Zee, CJ
    Pohl, NL
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2003, 226 : U213 - U213
  • [27] Determination of the affinity of biomimetic peptides for uranium through the simultaneous coupling of HILIC to ESI-MS and ICP-MS
    Abou-Zeid, Lana
    Pell, Albert
    Cortes, Marta Garcia
    Isnard, Helene
    Delangle, Pascale
    Bresson, Carole
    ANALYTICA CHIMICA ACTA, 2023, 1242
  • [28] Measurement of endogenous lysophosphatidic acid by ESI-MS/MS in plasma samples requires pre-separation of lysophosphatidylcholine
    Zhao, Zhenwen
    Xu, Yan
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2009, 877 (29): : 3739 - 3742
  • [29] Identification and characterization by ESI-MS/MS of proteins separated by gel electrophoresis
    Aebersold, R
    Figeys, D
    Ducret, A
    Gu, M
    Zhang, YN
    Watts, J
    FASEB JOURNAL, 1997, 11 (09): : A1121 - A1121
  • [30] Separation of human serum albumin components by RP-HPLC and CZE and their characterization by ESI-MS
    Girard, M
    Cyr, T
    Mousseau, N
    Ethier, JC
    CHROMATOGRAPHIA, 1999, 49 (Suppl 1) : S21 - S27