Liquid chromatographic/mass spectrometry assay of bromotetrandrine in rat plasma and its application to pharmacokinetic study

被引:4
|
作者
Song, Naining [1 ,2 ]
Zhang, Shaoyu [1 ,2 ]
Li, Quansheng [2 ]
Liu, Changxiao [2 ]
机构
[1] Tianjin Univ, Sch Chem Engn & Technol, Tianjin 300072, Peoples R China
[2] Tianjin Inst Pharmaceut Res, Natl Key Lab Pharmacokinet & Pharmacodynam, Tianjin 300193, Peoples R China
关键词
LC-MS/MS; bromotetrandrine; pharmacokinetics;
D O I
10.1002/bmc.1163
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A rapid and sensitive liquid chromatography-tandem mass spectrometric method (LC-MS/MS) for the determination of bromotetrandrine in rat plasma has been developed and applied to pharmacokinetic study in Sprague-Dawley (SD) rats after a single oral administration. Sample preparation involves a liquid-liquid extraction with n-hexane-dichlormethane (65:35, containing 1% 2-propanol isopropyl alcohol, v/v). Bromotetrandrine and brodimoprim (internal standard, IS) were well separated by LC with a Dikma C(18) column using methanol-ammonium formate aqueous solution (20 mm) containing 0.5% formic acid (60:40, v/v) as mobile phase. Detection was performed on a triple quadrupole mass spectrometer in multiple reaction monitoring mode. The ionization was optimized using ESI(+) and selectivity was achieved using MS/MS analysis, m/z 703.0 -> 461.0 and m/z 339.0 -> 281.0 for bromotetrandrine and IS, respectively. The present method exhibited good linearity over the concentration range of 20-5000 ng/mL for bromotetrandrine in rat plasma with a lower limit of quantification of 20 ng/mL. The intra- and inter-day precisions were 2.8-7.5% and 3.2-8.1%, and the intra- and inter-day accuracy ranged from -4.8 to 8.2% and -5.6 to 6.2%, respectively. The method was successfully applied to a pharmacokinetic study after a single oral administration to SD rats with bromotetrandrine of 50 mg/kg. Copyright (C) 2009 John Wiley & Sons, Ltd.
引用
收藏
页码:623 / 629
页数:7
相关论文
共 50 条
  • [21] Development and Validation of Liquid Chromatographic Tandem Mass Spectrometry for Determination and Pharmacokinetic Study of Glimepiride in Rat Plasma
    Zhou, Yunfang
    Wang, Shuanghu
    Ding, Ting
    Wu, Chunmei
    Wu, Mingdong
    Geng, Peiwu
    Hu, Guoxin
    Lin, Huiping
    LATIN AMERICAN JOURNAL OF PHARMACY, 2014, 33 (04): : 645 - 650
  • [22] Liquid chromatography/tandem mass spectrometry assay for the simultaneous determination of cefoperazone and sulbactam in plasma and its application to a pharmacokinetic study
    Zhou, Yingjie
    Zhang, Jing
    Guo, Beining
    Yu, Jicheng
    Shi, Yaoguo
    Wang, Minggui
    Zhang, Yingyuan
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2010, 878 (30): : 3119 - 3124
  • [23] Liquid chromatographic/mass spectrometric assay of rabprazole in dog plasma for a pharmacokinetic study
    Shao Feng
    Wang Guangji
    Sun Jianguo
    Xie Haitang
    Li Hao
    Lv Tian
    Zhu Xiaoyan
    Zhang Jingwei
    BIOMEDICAL CHROMATOGRAPHY, 2006, 20 (11) : 1136 - 1141
  • [24] Determination of astragaloside III in rat plasma by liquid chromatography-tandem mass spectrometry and its application to a rat pharmacokinetic study
    Zhai, Yongsong
    Li, Pengyue
    Wang, Manyuan
    Gong, Muxin
    Qiu, Feng
    BIOMEDICAL CHROMATOGRAPHY, 2016, 30 (02) : 105 - 110
  • [25] Determination of Sennoside A in Rat Plasma by Liquid Chromatography/Electrospray Ionization Tandem Mass Spectrometry and Its Application to a Rat Pharmacokinetic Study
    Sun, Jingjing
    Gu, Yifan
    Gu, Chunyan
    Qi, Wen
    Chu, Feifei
    Shen, Jiawei
    BIOMEDICAL CHROMATOGRAPHY, 2025, 39 (01)
  • [26] Development and validation of a liquid chromatography/tandem mass spectrometry assay for the quantification of methyl protodioscin in rat plasma: application to a pharmacokinetic study
    Cao, Xiuzhen
    Yao, Zhihong
    Chen, Haifeng
    Dai, Yi
    Sun, Pinghua
    Yei, Wencai
    Yao, Xinsheng
    BIOMEDICAL CHROMATOGRAPHY, 2008, 22 (04) : 408 - 413
  • [27] Development and validation of high-performance liquid chromatography/electrospray ionization mass spectrometry for assay of madecassoside in rat plasma and its application to pharmacokinetic study
    Han, Wen-Jing
    Xia, Yu-Feng
    Dai, Yue
    BIOMEDICAL CHROMATOGRAPHY, 2012, 26 (01) : 26 - 32
  • [28] Quantification of oltipraz using liquid chromatography-tandem mass spectrometry and its application to a pharmacokinetic study in rat plasma
    Lee, Jong-Hwa
    Lim, Hwanmi
    Kim, Do-Geun
    Park, Dae-Hun
    Woo, Young-Ah
    Noh, Hyun-Jung
    Jin, Qing-Ri
    Lee, Kyeong-Ryoon
    Lee, Gye-Won
    Kim, Choong-Yong
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2011, 56 (03) : 623 - 626
  • [29] A Sensitive Liquid Chromatography-Mass Spectrometry Method for Determination of Toosendanin in Rat Plasma and its Application to Pharmacokinetic Study
    Shen, Chuangpeng
    Pan, Zhisen
    Wu, Xiaojie
    Zhong, Chong
    Li, Qiao
    Si, Yuqi
    Liu, Changhui
    Tu, Haitao
    Deng, Zhijun
    Zhu, Zhangzhi
    Guo, Jiewen
    Xin, Xiaoyi
    Liu, Min
    JOURNAL OF CHROMATOGRAPHIC SCIENCE, 2022, 60 (05) : 478 - 485
  • [30] Determination of motolimod concentration in rat plasma by liquid chromatography-tandem mass spectrometry and its application in a pharmacokinetic study
    Ji, Yu-Geun
    Shin, Yu-Mi
    Jeong, Jong-Woo
    Choi, Hae-In
    Lee, Seung-Won
    Lee, Jong-Hwa
    Lee, Kyeong-Ryoon
    Koo, Tae-Sung
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2020, 179