Twenty-four-hour ambulatory blood pressure and heart rate profiles in diagnosing orthostatic hypotension in Parkinson's disease and multiple system atrophy

被引:32
|
作者
Vichayanrat, E. [1 ,2 ]
Low, D. A. [2 ,3 ]
Iodice, V. [1 ,2 ]
Stuebner, E. [4 ]
Hagen, E. M. [2 ]
Mathias, C. J. [1 ,2 ]
机构
[1] Natl Hosp Neurol & Neurosurg, Auton Unit, 2nd Floor Queen Mary Wing,Queen Sq, London WC1N 3BG, England
[2] St Marys Hosp, Imperial Coll London, Auton & Neurovascul Med Unit, Fac Med, London, England
[3] Liverpool John Moores Univ, Res Inst Sport & Exercise Sci, Liverpool, Merseyside, England
[4] Univ Witten Herdecke, Clin Neurol & Clin Neurophysiol, Ctr Res Clin Med ZFKM, Helios Clin Wuppertal, Wuppertal, Germany
关键词
autonomic failure; autonomic tests; cardiovascular autonomic function; multiple system atrophy; Parkinson's disease; SUPRACHIASMATIC NUCLEUS; PARAVENTRICULAR NUCLEUS; HYPERTENSION;
D O I
10.1111/ene.13135
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Background and purpose: Twenty-four-hour ambulatory blood pressure and heart rate monitoring (24-h ABPM) can provide vital information on circadian blood pressure (BP) profiles, which are commonly abnormal in Parkinson's disease with and without autonomic failure (PD + AF and PD) and multiple system atrophy (MSA). Twenty-four-hour ABPM has not been directly compared between these disorders regarding cardiovascular autonomic function. Our aim was to determine the usefulness of 24-h ABPM with diary compared to head-up tilting (HUT) in diagnosing orthostatic hypotension (OH) in these patients. Methods: Seventy-four patients (23 MSA, 18 PD + AF, 33 PD) underwent cardiovascular autonomic screening followed by 24-h ABPM with diary. Standing tests were included during 24-h ABPM. The sensitivity and specificity in detecting OH from the 24-h ABPM standing test were compared with HUT. Results: There was no difference in OH during HUT between MSA and PD + AF (P > 0.05). There was a higher proportion of abnormal BP circadian rhythms in MSA and PD + AF compared to PD (P < 0.05) but not between MSA and PD + AF (P > 0.05). Patients were divided into groups with OH (OH+) and without OH (OH similar to) on HUT. Using the standing test during 24-h ABPM, a systolic BP fall of > 20 mmHg showed a sensitivity and specificity of 82% and 100% (area under the curve 0.91, 95% confidence interval 0.84-0.98) in differentiating OH+ from OH-. Conclusions: Parkinson's disease with autonomic failure and MSA patients had similar circadian BP patterns suggesting that autonomic dysfunction influences abnormal BP circadian patterns similarly in these disorders. The higher sensitivity and specificity in detecting OH using a systolic BP fall of >20 mmHg compared to a diastolic BP fall of > 10 mmHg during the standing test supports its usefulness to assess autonomic function in MSA and PD.
引用
收藏
页码:90 / 97
页数:8
相关论文
共 50 条
  • [21] Twenty-four-hour ambulatory central blood pressure: new perspectives for blood pressure measurement?
    Salvi, Paolo
    Schillaci, Giuseppe
    Parati, Gianfranco
    JOURNAL OF HYPERTENSION, 2014, 32 (09) : 1774 - 1777
  • [22] Detection of orthostatic hypotension with ambulatory blood pressure monitoring in parkinson’s disease
    Fabrizio Vallelonga
    Alberto Romagnolo
    Aristide Merola
    Gabriele Sobrero
    Cristina Di Stefano
    Valeria Milazzo
    Jacopo Burrello
    Alessio Burrello
    Maurizio Zibetti
    Alberto Milan
    Franco Veglio
    Simona Maule
    Hypertension Research, 2019, 42 : 1552 - 1560
  • [23] Twenty-four-hour ambulatory blood pressure in old and very old subjects
    Fotherby, MD
    Potter, JF
    JOURNAL OF HYPERTENSION, 1995, 13 (12) : 1742 - 1746
  • [24] Role of Twenty-Four-Hour Ambulatory Blood Pressure Monitoring in Children on Dialysis
    Chaudhuri, Abanti
    Sutherland, Scott M.
    Begin, Brandy
    Salsbery, Kari
    McCabe, Lonisa
    Potter, Donald
    Alexander, Steven R.
    Wong, Cynthia J.
    CLINICAL JOURNAL OF THE AMERICAN SOCIETY OF NEPHROLOGY, 2011, 6 (04): : 870 - 876
  • [25] Detection of orthostatic hypotension with ambulatory blood pressure monitoring in parkinson's disease
    Vallelonga, Fabrizio
    Romagnolo, Alberto
    Merola, Aristide
    Sobrero, Gabriele
    Di Stefano, Cristina
    Milazzo, Valeria
    Burrello, Jacopo
    Burrello, Alessio
    Zibetti, Maurizio
    Milan, Alberto
    Veglio, Franco
    Maule, Simona
    HYPERTENSION RESEARCH, 2019, 42 (10) : 1552 - 1560
  • [26] Twenty-four-Hour Ambulatory Blood Pressure Monitor Heart Rate: A Potential Marker for Gestational Hypertension in at-Risk Women
    Booker, Corenthian J.
    Dodson, William C.
    Kunselman, Allen R.
    Repke, John T.
    Legro, Richard S.
    AMERICAN JOURNAL OF PERINATOLOGY, 2012, 29 (05) : 339 - 346
  • [27] Prediction of orthostatic hypotension in multiple system atrophy and Parkinson disease
    Zhanfang Sun
    Dandan Jia
    Yuting Shi
    Xuan Hou
    Xiaosu Yang
    Jifeng Guo
    Nan Li
    Junling Wang
    Qiying Sun
    Hainan Zhang
    Lifang Lei
    Lu Shen
    Xinxiang Yan
    Kun Xia
    Hong Jiang
    Beisha Tang
    Scientific Reports, 6
  • [28] Prediction of orthostatic hypotension in multiple system atrophy and Parkinson disease
    Sun, Zhanfang
    Jia, Dandan
    Shi, Yuting
    Hou, Xuan
    Yang, Xiaosu
    Guo, Jifeng
    Li, Nan
    Wang, Junling
    Sun, Qiying
    Zhang, Hainan
    Lei, Lifang
    Shen, Lu
    Yan, Xinxiang
    Xia, Kun
    Jiang, Hong
    Tang, Beisha
    SCIENTIFIC REPORTS, 2016, 6
  • [29] Orthostatic hypotension and dementia risk in Parkinson's disease and multiple system atrophy
    Ruiz-Barrio, I.
    Miki, Y.
    Warner, T.
    De Pablo Fernandez, E.
    EUROPEAN JOURNAL OF NEUROLOGY, 2022, 29 : 318 - 319
  • [30] The differences of orthostatic hypotension in patients with Parkinson's disease and multiple system atrophy
    Zeng, Jingrong
    Xing, Yingqi
    Mei, Shanshan
    Xu, Baolei
    Xue, Xiaofan
    Song, Haixia
    Xu, Erhe
    FRONTIERS IN NEUROLOGY, 2023, 14