PERFORMANCE EVALUATION OF A COMMERCIALLY AVAILABLE DESICCANT-BASED SEED DRYING SYSTEM

被引:1
|
作者
Dien, Alice [1 ]
Momin, Md Abdul [1 ,2 ]
Ying, Tianyu [3 ]
Spang, Edward S. [4 ]
Kornbluth, Kurt [1 ]
Donis-Gonzalez, Irwin R. [1 ]
机构
[1] Univ Calif Davis, Dept Biol & Agr Engn, Davis, CA 95616 USA
[2] Univ Arkansas, Dept Agr, Pine Bluff, AR USA
[3] Univ Calif Davis, Energy & Efficiency Inst, Davis, CA 95616 USA
[4] Univ Calif Davis, Dept Food Sci & Technol, Davis, CA 95616 USA
来源
JOURNAL OF THE ASABE | 2022年 / 65卷 / 03期
关键词
Dehydration; Energy; Food safety; Moisture; Regeneration; HEAT-PUMP DRYER; SORPTION;
D O I
10.13031/ja.14762
中图分类号
S2 [农业工程];
学科分类号
0828 ;
摘要
FlexiDry (R) is a commercially available desiccant-based drying system designed to reduce seed moisture content and promote seed preservation. The purpose of this study was to evaluate FlexiDry in drying 130 kg of whole yellow corn kernels (Zea mays) for large-scale human and animal consumption. FlexiDry was tested in two treatments, using heated (HA) and unheated (UA) air, and compared to conventional heated-air (CHA) drying. The desiccant (Drying Beads) was regenerated (moisture removed) at 250 degrees C using a furnace within the FlexiDry system. All treatments properly dried the corn below the target value of 15% dry basis moisture content (M-D). The CHA and HA treatments yielded an average moisture extraction rate (MER) of 1.42 kg h(-1), compared to 0.58 kg h(-1). for the UA treatment. In terms of energy consumption, the specific moisture extraction rate (SMER) was 0.20, 0.44, and 1.11 kg kWh(-1) for the UA, HA, and CHA treatments, respectively. The coefficient of performance (COP), i.e., the ratio between the theoretical heat delivered and the total energy consumed, was 0.14, 0.30, and 0.75 for the UA, HA, and CHA treatments, respectively. The FlexiDry treatments (HA and UA) consumed more energy than the CHA treatment, with more than 85% of the energy consumption used to regenerate the Drying Beads. The system yielded a global warming potential (GWP) of 0.931 and 0.425 kg CO2-eq kg(-1) of water removed for the UA and HA treatments, respectively. These values are higher than the GWP of the U.S. corn industry drying standard, which is reported as 0.383 kg CO2-eq kg(-1 )water. Thus, if the regeneration process can be optimized, there is potential for reductions in energy intensity and GWP with large-scale, desiccant-based drying of agricultural commodities.
引用
收藏
页码:633 / 643
页数:11
相关论文
共 50 条
  • [31] Using a Commercially Available System for MLC Logfile Based Delivery Verification and Plan Evaluation
    Stathakis, S.
    Cuthbert, T.
    Jones, W.
    Mavroidis, P.
    [J]. MEDICAL PHYSICS, 2022, 49 (06) : E898 - E898
  • [32] Experimental analysis of a solar assisted desiccant-based space heating and humidification system for cold and dry climates
    Kashif, Aizaz
    Ali, Muzaffar
    Sheikh, Nadeem Ahmed
    Vukovic, Vladimir
    Shehryar, M.
    [J]. APPLIED THERMAL ENGINEERING, 2020, 175
  • [33] Technical feasibility study of a compact desiccant-based outdoor air system using cogenerated hot water
    Park, Beungyong
    Lee, Sihwan
    Kato, Shinsuke
    [J]. APPLIED THERMAL ENGINEERING, 2016, 106 : 968 - 980
  • [34] Experimental analysis of an unconventional desiccant-based air-conditioning system: the influence of cooling air flow and chiller on the energy and environmental performance
    Angrisani, G.
    Minichiello, F.
    Sasso, M.
    [J]. INTERNATIONAL JOURNAL OF LOW-CARBON TECHNOLOGIES, 2015, 10 (04) : 321 - 331
  • [35] Performance Analysis of VLC system using Commercially Available Components
    Khani, Talha Kaim
    Mangrio, Hyder Bux
    Umrani, Fahim Aziz
    [J]. 2019 22ND IEEE INTERNATIONAL MULTI TOPIC CONFERENCE (INMIC), 2019, : 314 - 317
  • [36] A novel hybrid desiccant-based ejector cooling system for energy and carbon saving in hot and humid climates
    Heidari, Amirreza
    Rostamzadeh, Hadi
    Avami, Akram
    [J]. INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2019, 101 : 196 - 210
  • [37] Toward self-powered integrated smart packaging system- Desiccant-based triboelectric nanogenerators
    Pang, Yaokun
    Huang, Zhida
    Fang, Yuhui
    Xu, Xianchen
    Cao, Changyong
    [J]. NANO ENERGY, 2023, 114
  • [38] Dynamic performance assessment of a solar-assisted desiccant-based air handling unit in two Italian cities
    Angrisani, G.
    Roselli, C.
    Sasso, M.
    Tariello, F.
    [J]. ENERGY CONVERSION AND MANAGEMENT, 2016, 113 : 331 - 345
  • [39] A methodology for the performance evaluation of an experimental desiccant cooling system
    Çarpinlioglu, MO
    Yildirim, M
    [J]. INTERNATIONAL COMMUNICATIONS IN HEAT AND MASS TRANSFER, 2005, 32 (10) : 1400 - 1410
  • [40] COMMERCIALLY AVAILABLE LANGUAGE ARTS PERFORMANCE-BASED ASSESSMENTS
    VALENCIA, SW
    COMMEYRAS, M
    [J]. READING TEACHER, 1992, 45 (06): : 468 - 470