Near-infrared spectroscopy and imaging for investigating stroke rehabilitation: Test-retest reliability and review of the literature

被引:51
|
作者
Strangman, Gary
Goldstein, Richard
Rauch, Scott L.
Stein, Joel
机构
[1] Harvard Univ, Sch Med, Massachusetts Gen Hosp, Div Psychiat Neurosci,Neural Syst Grp, Charlestown, MA 02129 USA
[2] Harvard Univ, Sch Med, Spaulding Rehabil Hosp, Div Behav & Mental Hlth, Boston, MA USA
[3] Harvard Univ, Sch Med, Spaulding Rehabil Hosp, Dept Phys Med & Rehabil, Boston, MA USA
来源
关键词
hemodynamics; motor skills; oxyhemoglobins; rehabilitation; spectroscopy; near infrared;
D O I
10.1016/j.apmr.2006.07.269
中图分类号
R49 [康复医学];
学科分类号
100215 ;
摘要
Objectives: To review the use of near-infrared spectroscopy (NIRS) in stroke rehabilitation and to evaluate NIRS test-retest reliability within-session on a motor control task commonly used in neuroimaging of stroke recovery. Design: Cohort study. Setting: Hospital-based research laboratory. Participants: Nineteen healthy control subjects (age range, 22-55y). Interventions: Subjects performed 2 experimental runs of a finger-opposition task in a block-design paradigm (finger opposition alternated with a fixation rest period) while undergoing multichannel NIRS and physiologic monitoring. Main Outcome Measure: Reliability coefficients (Pearson r) for oxyhemoglobin (O(2)Hb) and deoxyhemoglobin (HHb) correlated amplitude modulations across measurement channels during individual blocks and block averages. Results: Correlations between single blocks (ie, 16-s slices of data) exhibited a correlation intercept of 33 +/- .09 for O(2)Hb. This value was minimally decreased by increasing lag between compared blocks (slope, -.012; P=.019) but was substantially enhanced by averaging across blocks (within-run slope, 11: between-run slope, .044). Correlations using 64 seconds of data reached 0.6. Results for HHb were virtually identical. Conclusions: NIRS modulations were repeatable even when comparing very short segments of data. When averaging longer data segments, the test-retest correspondences compared favorably to neuroimaging using other modalities. This suggests that NIRS is a reliable tool for longitudinal stroke rehabilitation and recovery studies.
引用
收藏
页码:S12 / S19
页数:8
相关论文
共 50 条
  • [1] Test-retest and deasibility evaluation of near-infrared spectroscopy for use in stroke rehabilitation
    Strangman, Gary E.
    Goldstein, Richard
    Stein, Joel
    Rauch, Scott L.
    NEUROLOGY, 2007, 68 (12) : A176 - A177
  • [2] Test-retest reliability of functional near infrared spectroscopy in infants
    Blasi, Anna
    Lloyd-Fox, Sarah
    Johnson, Mark. H.
    Elwell, Clare
    NEUROPHOTONICS, 2014, 1 (02)
  • [3] Test-retest reliability of the prefrontal response to affective pictures based on functional near-infrared spectroscopy
    Huang, Yuxia
    Mao, Mengchai
    Zhang, Zong
    Zhou, Hui
    Zhao, Yang
    Duan, Lian
    Kreplin, Ute
    Xiao, Xiang
    Zhu, Chaozhe
    JOURNAL OF BIOMEDICAL OPTICS, 2017, 22 (01)
  • [4] Evaluation Of Inter-rater And Test-retest Reliability For Near-infrared Spectroscopy Reactive Hyperemia Measures
    McGranahan, Melissa J.
    Kibildis, Samuel W.
    McCully, Kevin K.
    Jenkins, Nathan T.
    MEDICINE & SCIENCE IN SPORTS & EXERCISE, 2020, 52 (07) : 238 - 238
  • [5] Evaluation of inter-rater and test-retest reliability for near-infrared spectroscopy reactive hyperemia measures
    McGranahan, Melissa J.
    Kibildis, Samuel W.
    McCully, Kevin K.
    O'Connor, Patrick J.
    MICROVASCULAR RESEARCH, 2023, 148
  • [6] Sex Differences in Test-Retest Reliability of Near-Infrared Spectroscopy During Postocclusive Reactive Hyperemia of the Vastus Lateralis
    Shoemaker, Marni E.
    Smith, Cory M.
    Gillen, Zachary M.
    Cramer, Joel T.
    JOURNAL OF STRENGTH AND CONDITIONING RESEARCH, 2024, 38 (02) : e40 - e48
  • [7] Test-retest reliability of brain mitochondrial cytochrome-c-oxidase assessed by functional near-infrared spectroscopy
    Holper, Lisa
    Mann, J. John
    JOURNAL OF BIOMEDICAL OPTICS, 2018, 23 (05)
  • [8] Test-retest reliability of the GAITRite system in people with stroke undergoing rehabilitation
    Kuys, Suzanne S.
    Brauer, Sandra G.
    Ada, Louise
    DISABILITY AND REHABILITATION, 2011, 33 (19-20) : 1848 - 1853
  • [9] Test-retest reliability of functional near-infrared spectroscopy during a finger-tapping and postural task in healthy older adults
    de Rond, Veerle
    Gilat, Moran
    D'Cruz, Nicholas
    Hulzinga, Femke
    Orban de Xivry, Jean-Jacques
    Nieuwboer, Alice
    NEUROPHOTONICS, 2023, 10 (02)
  • [10] THE TEST OF ORIENTATION FOR REHABILITATION PATIENTS - TEST-RETEST RELIABILITY
    DEITZ, JC
    TOVAR, VS
    BEEMAN, C
    THORN, DW
    TREVISAN, MS
    OCCUPATIONAL THERAPY JOURNAL OF RESEARCH, 1992, 12 (03): : 172 - 185