Test-retest reliability of functional near-infrared spectroscopy during a finger-tapping and postural task in healthy older adults

被引:7
|
作者
de Rond, Veerle [1 ]
Gilat, Moran [1 ,2 ]
D'Cruz, Nicholas [1 ,3 ]
Hulzinga, Femke [1 ]
Orban de Xivry, Jean-Jacques [2 ,3 ]
Nieuwboer, Alice [1 ,2 ]
机构
[1] Katholieke Univ Leuven, Dept Rehabil Sci, Neurorehabil Res Grp, Leuven, Belgium
[2] Leuven Brain Inst, Leuven, Belgium
[3] Katholieke Univ Leuven, Dept Kinesiol, Motor Control & Neuroplast Res Grp, Leuven, Belgium
关键词
Functional near-infrared spectroscopy; ageing; test-retest; reliability; postural control; finger tapping; OXYGENATION; MOTOR; PEOPLE; VOLUME;
D O I
10.1117/1.NPh.10.2.025010
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
Significance: Functional near-infrared spectroscopy (fNIRS) is increasingly employed in studies requiring repeated measurements, yet test-retest reliability is largely unknown. Aim: To investigate test-retest reliability during a postural and a finger-tapping task with and without cap-removal. Approach: Twenty healthy older adults performed a postural and a finger-tapping task. The tasks were repeated twice in one session and once the next day. A portable fNIRS system measured cortical hemodynamics (HbO(2)) in five regions of interest for the postural task and in the hand motor region for finger-tapping. Results: Test-retest reliability without cap-removal was excellent for the prefrontal cortex (PFC), the premotor cortex (PMC) and the somatosensory cortex (SSC) (intraclass correlation coefficient oICCTHORN >= 0.78), and fair for the frontal eye fields (FEF) and the supplementary motor area (SMA) (ICC >= 0.48). After cap-removal, reliability reduced for PFC and SSC (ICC = 0.50), became poor for SMA (ICC = 0.01) and PMC (ICC = 0.00) and remained good for FEF (ICC = 0.64). Similarly, good reliability (ICC = 0.66) was apparent for the hand motor region without cap-removal, which deteriorated after cap-removal (ICC = 0.38). Conclusions: Test-retest reliability of fNIRS measurements during two separate motor tasks in healthy older adults was fair to excellent when the cap remained in place. However, removing the fNIRS cap between measurements compromised reliability. (c) The Authors. Published by SPIE under a Creative Commons Attribution 4.0 International License. Distribution or reproduction of this work in whole or in part requires full attribution of the original publication, including its DOI.
引用
收藏
页数:20
相关论文
共 50 条
  • [1] Test-retest reliability of a finger-tapping fMRI task in a healthy population
    Wuethrich, Florian
    Lefebvre, Stephanie
    Nadesalingam, Niluja
    Bernard, Jessica A.
    Mittal, Vijay A.
    Shankman, Stewart A.
    Walther, Sebastian
    EUROPEAN JOURNAL OF NEUROSCIENCE, 2023, 57 (01) : 78 - 90
  • [2] Test-retest reliability of functional near infrared spectroscopy in infants
    Blasi, Anna
    Lloyd-Fox, Sarah
    Johnson, Mark. H.
    Elwell, Clare
    NEUROPHOTONICS, 2014, 1 (02)
  • [3] Test-retest reliability of the prefrontal response to affective pictures based on functional near-infrared spectroscopy
    Huang, Yuxia
    Mao, Mengchai
    Zhang, Zong
    Zhou, Hui
    Zhao, Yang
    Duan, Lian
    Kreplin, Ute
    Xiao, Xiang
    Zhu, Chaozhe
    JOURNAL OF BIOMEDICAL OPTICS, 2017, 22 (01)
  • [4] Test-retest reliability of the functional rotation test in healthy adults
    Batavia, M
    Gianutsos, JG
    PERCEPTUAL AND MOTOR SKILLS, 2003, 96 (01) : 185 - 196
  • [5] Test-Retest Assessment of Functional Near-Infrared Spectroscopy to measure Risk Decision Making in Young Adults
    Li, Lin
    Lin, Zijing
    Mary, Cazzell
    Liu, Hanli
    PHOTONIC THERAPEUTICS AND DIAGNOSTICS IX, 2013, 8565
  • [6] Test-retest reliability of brain mitochondrial cytochrome-c-oxidase assessed by functional near-infrared spectroscopy
    Holper, Lisa
    Mann, J. John
    JOURNAL OF BIOMEDICAL OPTICS, 2018, 23 (05)
  • [7] Sex Differences in Test-Retest Reliability of Near-Infrared Spectroscopy During Postocclusive Reactive Hyperemia of the Vastus Lateralis
    Shoemaker, Marni E.
    Smith, Cory M.
    Gillen, Zachary M.
    Cramer, Joel T.
    JOURNAL OF STRENGTH AND CONDITIONING RESEARCH, 2024, 38 (02) : e40 - e48
  • [8] Near-infrared spectroscopy and imaging for investigating stroke rehabilitation: Test-retest reliability and review of the literature
    Strangman, Gary
    Goldstein, Richard
    Rauch, Scott L.
    Stein, Joel
    ARCHIVES OF PHYSICAL MEDICINE AND REHABILITATION, 2006, 87 (12): : S12 - S19
  • [9] Test-retest reliability of the GAPP functional capacity evaluation in healthy adults
    Gibson, Libby A.
    Dang, Monica
    Strong, Jenny
    Khan, Asad
    CANADIAN JOURNAL OF OCCUPATIONAL THERAPY-REVUE CANADIENNE D ERGOTHERAPIE, 2010, 77 (01): : 38 - 47
  • [10] Is resting-state functional connectivity revealed by functional near-infrared spectroscopy test-retest reliable?
    Zhang, Han
    Zhang, Yu-Jin
    Duan, Lian
    Ma, Shuang-Ye
    Lu, Chun-Ming
    Zhu, Chao-Zhe
    JOURNAL OF BIOMEDICAL OPTICS, 2011, 16 (06)