Spatial-resolution enhancement in micro-CT

被引:0
|
作者
Pan, XC [1 ]
Yu, LF [1 ]
Kao, CM [1 ]
Pelizzari, C [1 ]
机构
[1] Univ Chicago, Dept Radiol, Chicago, IL 60637 USA
关键词
computed tomography (CT); image reconstruction; micro-CT;
D O I
10.1109/NSSMIC.2003.1352589
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
We propose a new strategy to improve sampling density and image resolution in micro-CT without changing hardware and without sacrificing the size of the allowable maximum field of view (FOV). Such a strategy is achieved by use of the asymmetric scanning configurations in which the center of rotation is moved to an off-center position and a reconstruction algorithm specifically developed for such configurations. We conducted numerical studies to validate and evaluate the proposed strategy, and quantitative results in these studies confirm that the proposed configurations and algorithm can significantly improve spatial resolution properties in micro-Cl
引用
下载
收藏
页码:3244 / 3247
页数:4
相关论文
共 50 条
  • [31] THE LIMITS OF SPATIAL-RESOLUTION IN PIXE
    LEGGE, GJF
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 1987, 22 (1-3): : 115 - 120
  • [32] HIGH SPATIAL-RESOLUTION MICROANALYSIS
    NICHOLLS, AW
    BOVEY, PE
    JOURNAL OF ELECTRON MICROSCOPY TECHNIQUE, 1987, 7 (02): : 141 - 141
  • [33] SPATIAL-RESOLUTION OF THERMOGRAPHIC CAMERAS
    STEKETEE, J
    BIBLIOTHECA RADIOLOGICA, 1975, (06) : 25 - 32
  • [34] SPATIAL-RESOLUTION OF INDUCTION CHAMBERS
    BONDAR, AE
    ONUCHIN, AP
    PANIN, VS
    TELNOV, VI
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH, 1983, 207 (03): : 379 - 388
  • [35] FOURIER SPECTROMETRY WITH SPATIAL-RESOLUTION
    DUBKOV, VI
    OPTIKA I SPEKTROSKOPIYA, 1984, 57 (01): : 152 - 154
  • [36] THE SPATIAL-RESOLUTION OF THE ALEPH TPC
    AMENDOLIA, SR
    BARCZEWSKI, T
    BAUERDICK, LAT
    BLUCHER, E
    BLUM, W
    BOUDREAU, J
    CINABRO, D
    CIOCCI, MA
    CONWAY, J
    COWEN, DF
    FIDECARO, F
    GOBBO, B
    HALLEY, A
    HAYWOOD, S
    JAHN, A
    JOHNSON, R
    KASEMANN, M
    LARSSON, U
    LECLAIRE, B
    LEHRAUS, I
    LOHSE, T
    LUSIANI, A
    MARROCCHESI, PS
    MAY, J
    MILOTTI, E
    MINTEN, A
    RICHSTEIN, J
    RICHTER, R
    ROEHN, S
    ROLANDI, L
    SCHLATTER, D
    SCHMELLING, M
    SETTLES, R
    STEFANINI, G
    STEEG, F
    TAKASHIMA, M
    TEJESSY, W
    THOMAS, J
    VAYAKI, A
    WEAR, J
    WITZELING, W
    WU, SL
    XUE, S
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1989, 283 (03): : 573 - 577
  • [37] MODIS SPATIAL-RESOLUTION STUDY
    JUSTICE, CO
    TOWNSHEND, JRG
    MARKHAM, BL
    INTERNATIONAL JOURNAL OF REMOTE SENSING, 1987, 8 (08) : 1119 - 1121
  • [38] PHOTODETECTOR WITH SUBWAVELENGTH SPATIAL-RESOLUTION
    KOLB, G
    OBERMULLER, C
    KARRAI, K
    ABSTREITER, G
    BOHM, G
    TRANKLE, G
    WEIMANN, G
    ULTRAMICROSCOPY, 1995, 57 (2-3) : 208 - 211
  • [39] LIMITATIONS OF THE SPATIAL-RESOLUTION IN SIMS
    LIEBL, H
    FRESENIUS ZEITSCHRIFT FUR ANALYTISCHE CHEMIE, 1983, 314 (03): : 244 - 244
  • [40] HIGH SPATIAL-RESOLUTION OF PANCAKES
    BUCHERT, T
    ASTROPHYSICS AND SPACE SCIENCE, 1990, 171 (1-2) : 135 - 139