Influence of fluorophore and linker length on the localization and trafficking of fluorescent sterol probes

被引:9
|
作者
Kralova, Jarmila [1 ]
Jurasek, Michal [2 ]
Miksatkova, Lucie [2 ]
Maresova, Anna [2 ]
Faehnrich, Jan [2 ]
Cihlarova, Petra [2 ]
Drasar, Pavel [2 ]
Bartunek, Petr [1 ]
Kral, Vladimir [2 ]
机构
[1] Czech Acad Sci, Inst Mol Genet, CZ OPENSCREEN, Vvi, Videnska 1083, Prague 14220 4, Czech Republic
[2] Univ Chem & Technol, Tech 5, Prague 16628 6, Czech Republic
关键词
CHOLESTEROL ANALOGS; BODIPY;
D O I
10.1038/s41598-020-78085-9
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Fluorescent sterol probes, comprising a fluorophore connected to a sterol backbone by means of a linker, are promising tools for enabling high-resolution imaging of intracellular cholesterol. In this study, we evaluated how the size of the linker, site of its attachment and nature of the fluorophore, affect the localization and trafficking properties of fluorescent sterol probes. Varying lengths of linker using the same fluorophore affected cell penetration and retention in specific cell compartments. A C-4 linker was confirmed as optimal. Derivatives of heterocyclic sterol precursors attached with identical C-4 linker to different fluorophores at diverse positions also showed significant differences in their binding properties to various intracellular compartments and kinetics of trafficking. Two novel red-emitting probes with good cell permeability, fast intracellular labelling and slightly different distribution displayed very promising characteristics for sterol probes. These probes also strongly labelled endo/lysosomal compartment in cells with pharmacologically disrupted cholesterol transport, or with a genetic mutation of cholesterol transporting protein NPC1, that overlapped with filipin staining of cholesterol. Overall, the present study demonstrates that the physicochemical properties of the fluorophore/linker pairing determine the kinetics of uptake and distribution and subsequently influence the applicability of final probes.
引用
收藏
页数:11
相关论文
共 50 条
  • [41] Distance and linker chemistry control of on vs. off fluorescent response in probes for manganese ions
    Li, Chen
    Canary, James
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2012, 244
  • [42] Permeability and localization of nitroxide pre-fluorescent probes in epithelial cells
    Aspee, Alexis
    Bar-Magen, Tamara
    Villareal, Jose Miguel
    Mikelsons, Larisa
    Saavedra, Claudia
    Scaiano, J. C.
    FREE RADICAL RESEARCH, 2007, 41 : S17 - S17
  • [43] MEMBRANE FLUORESCENT-PROBES .1. INCORPORATION OF ANTHRYL FLUOROPHORE INTO THE HYDROPHOBIC MOIETY OF NATURAL PHOSPHATIDYLCHOLINE AND PHOSPHATIDYLETHANOLAMINE
    BOGOMOLOV, OV
    KAPLUN, AP
    SHVETS, VI
    BIOORGANICHESKAYA KHIMIYA, 1984, 10 (11): : 1560 - 1564
  • [44] Influence of linker length in shape recognition of B* DNA by dimeric aminoglycosides
    Kumar, Sunil
    Spano, Meredith Newby
    Arya, Dev P.
    BIOORGANIC & MEDICINAL CHEMISTRY, 2015, 23 (13) : 3105 - 3109
  • [45] Use of fluorescent probes to determine catalytic chain length in chemically amplified resists
    Frenette, M
    Ivan, MG
    Scaiano, JC
    CANADIAN JOURNAL OF CHEMISTRY, 2005, 83 (6-7) : 869 - 874
  • [46] AIE and UIA-featured fluorescent ligands for G-quadruplex: the impact of linker rigidity between recognition moiety and fluorophore
    Wang, Rui
    Hu, Ming-Hao
    CHEMICAL COMMUNICATIONS, 2025, 61 (26) : 4991 - 4994
  • [47] Two-Photon Fluorescent Probes for Biomembrane Imaging: Effect of Chain Length
    Kim, Hwan Myung
    Kim, Bo Ra
    Choo, Hyo-Jung
    Ko, Young-Gyu
    Jeon, Seung-Joon
    Kim, Chul Hoon
    Joo, Taiha
    Cho, Bong Rae
    CHEMBIOCHEM, 2008, 9 (17) : 2830 - 2838
  • [48] DIRECTLY LABELED DNA PROBES USING FLUORESCENT NUCLEOTIDES WITH DIFFERENT LENGTH LINKERS
    ZHU, ZR
    CHAO, J
    YU, H
    WAGGONER, AS
    NUCLEIC ACIDS RESEARCH, 1994, 22 (16) : 3418 - 3422
  • [49] INFLUENCE OF FLUORESCENT LIPID PROBES ON THE PACKING OF THEIR ENVIRONMENT - A MONOLAYER STUDY
    BREDLOW, A
    GALLA, HJ
    BERGELSON, LD
    CHEMISTRY AND PHYSICS OF LIPIDS, 1992, 62 (03) : 293 - 301
  • [50] DETERMINATION OF FLUORESCENT-PROBES LOCALIZATION IN MEMBRANES BY NONRADIATIVE ENERGY-TRANSFER
    DOBRETSOV, GE
    KUREK, NK
    MACHOV, VN
    SYREJSHCHIKOVA, TI
    YAKIMENKO, MN
    JOURNAL OF BIOCHEMICAL AND BIOPHYSICAL METHODS, 1989, 19 (04): : 259 - 274