Respiratory correlated segment reconstruction algorithm towards four-dimensional radiation therapy using carbon ion beams

被引:4
|
作者
Mori, Shinichiro
Endo, Masahiro
Kohno, Ryosuke
Asakura, Hiroshi
Kohno, Kazutoshi
Yashiro, Tomoyasu
Komatsu, Shuhei
Kandatsu, Susumu
Baba, Masayuki
机构
[1] Natl Inst Radiol Sci, Radiol Protect Sect, Chiba 260, Japan
[2] Natl Inst Radiol Sci, Dept Planning & Management, Chiba 260, Japan
[3] Natl Canc Ctr E, Dept Radiat Oncol, Kashiwa, Chiba, Japan
[4] Accelerator Engn Corp, Inage Ku, Chiba, Japan
[5] Hosp Chiba, Natl Inst Radiol Sci, Chiba, Japan
关键词
respiration; target volume; image quality; temporal resolution; carbon-beam;
D O I
10.1016/j.radonc.2006.07.035
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: To enhance the precision of treatment planning for tumors which move under respiration, we developed a respiratory-correlated segment reconstruction method (RS) based on the Feldkamp-Davis-Kress algorithm (FDK) which provides high temporal resolution and a high signal-to-noise ratio. We compared full-scan (FS-FDK) and RS-FDK with regard to dose distribution in heavy ion treatment planning. Materials and methods: Data acquisition for RS-FDK is done using a respiratory sensing system in cine scan mode with a 256-multi-detector row CT (256-MDCT). To evaluate the accuracy of irradiation of moving tumors, dose distributions with each algorithm were compared in heavy ion treatment planning using beam parameters obtained with FS-FDK. Results: Images obtained using RS-FDK did not show motion artifacts and visualized the edges of the liver and pulmonary vessels more clearly than those with FS-FDK. The iso-dose distributions for FS-FDK covered the target volume; in contrast, RS-FDK with the beam parameter of FS-FDK image provided an insufficient dose to the target and a considerable dose to normal tissues around it. Conclusions: The information provided by RS-FDK improves accuracy in the prescription of dose-to-target volume. Further, RS-FDK allows greater precision in the delivery of radiotherapy, including 4D radiation therapy. (c) 2006 Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:341 / 348
页数:8
相关论文
共 50 条
  • [41] Simulation study for the energy and position reconstruction performances of the beam monitoring system of Carbon Ion Radiation Therapy using GEANT4
    Eo, Yun
    Kwon, Na Hye
    Bae, Joonsuk
    Cheon, Byunggu
    Cho, Guk
    Choi, Suyong
    Do, Hyunsuk
    Ha, Seungkyu
    Huh, Changgi
    Hwang, Kyuyeong
    Jang, Haeun
    Jang, Seoyun
    Jang, Yoonjun
    Jeong, Jinryong
    Kim, Beomkyu
    Kim, Bobae
    Kim, Dongwoon
    Kim, Sungwon
    Ko, Sanghyun
    Lee, Hyupwoo
    Lee, Hyungjun
    Lee, Jason
    Lee, Junghyun
    Lee, Sehwook
    Lee, Woochan
    Lee, Yunjae
    Lim, Sanghoon
    Park, Hyesung
    Ryu, Jaehyeok
    Kim, Jin Sung
    Ryu, Min Sang
    Yoo, Hwidong
    Kim, Dong Wook
    Kim, Minsuk
    PLOS ONE, 2025, 20 (02):
  • [42] Four-Dimensional Cone-Beam Computed Tomography and Digital Tomosynthesis Using Motion Signals Extracted from Fiducial Marker Inserted for Liver Cancer Radiation Therapy
    Park, J.
    Park, S.
    Kim, J.
    Liu, Z.
    Watkins, W.
    Song, W.
    MEDICAL PHYSICS, 2010, 37 (06)
  • [43] Four-dimensional carbon-ion pencil beam treatment planning comparison between robust optimization and range-adapted internal target volume for respiratory-gated liver and lung treatment
    Kanai, Takayuki
    Paz, Athena
    Furuichi, Wataru
    Liu, Ching-Sheng
    He, Pengbo
    Mori, Shinichiro
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2020, 80 : 277 - 287
  • [44] Design of a compensating bolus by use of exhalation CT data for covering residual motion in respiratory-gated charged-particle lung therapy: four-dimensional carbon beam dose calculation.
    Mori S.
    Asakura H.
    Komatsu S.
    Yashiro T.
    Kumagai M.
    Kandatsu S.
    Baba M.
    Endo M.
    Radiological Physics and Technology, 2008, 1 (1) : 83 - 88
  • [45] Predicting the Relative Biological Effectiveness of Carbon Ion Radiation Therapy Beams Using the Mechanistic Repair-Misrepair-Fixation (RMF) Model and Nuclear Fragment Spectra
    Kamp, F.
    Cabal, G.
    Mairani, A.
    Parodi, K.
    Wilkens, J. J.
    Carlson, D. J.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2014, 90 : S849 - S849
  • [46] Comparison of planned dose on different CT image sets to four-dimensional Monte Carlo dose recalculation using the patient's actual breathing trace for lung stereotactic body radiation therapy
    Freislederer, Philipp
    von Muenchow, Asmus
    Kamp, Florian
    Heinz, Christian
    Gerum, Sabine
    Corradini, Stefanie
    Soehn, Matthias
    Reiner, Michael
    Roeder, Falk
    Floca, Ralf
    Alber, Markus
    Belka, Claus
    Parodi, Katia
    MEDICAL PHYSICS, 2019, 46 (07) : 3268 - 3277
  • [47] A feasibility study of high-dose hypofractionated carbon ion radiation therapy using four fractions for localized hepatocellular carcinoma measuring 3 cm or larger
    Shibuya, Kei
    Ohno, Tatsuya
    Katoh, Hiroyuki
    Okamoto, Masahiko
    Shiba, Shintaro
    Koyama, Yoshinori
    Kakizaki, Satoru
    Shirabe, Ken
    Nakano, Takashi
    RADIOTHERAPY AND ONCOLOGY, 2019, 132 : 230 - 235
  • [48] A computerized framework for monitoring four-dimensional dose distributions during stereotactic body radiation therapy using a portal dose image-based 2D/3D registration approach
    Nakamoto, Takahiro
    Arimura, Hidetaka
    Nakamura, Katsumasa
    Shioyama, Yoshiyuki
    Mizoguchi, Asumi
    Hirose, Taka-aki
    Honda, Hiroshi
    Umezu, Yoshiyuki
    Nakamura, Yasuhiko
    Hirata, Hideki
    COMPUTERIZED MEDICAL IMAGING AND GRAPHICS, 2015, 40 : 1 - 12
  • [49] Evaluation of the motion of lung tumors during stereotactic body radiation therapy (SBRT) with four-dimensional computed tomography (4DCT) using real-time tumor-tracking radiotherapy system (RTRT)
    Harada, Keiichi
    Katoh, Norio
    Suzuki, Ryusuke
    Ito, Yoichi M.
    Shimizu, Shinichi
    Onimaru, Rikiya
    Inoue, Tetsuya
    Miyamoto, Naoki
    Shirato, Hiroki
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2016, 32 (02): : 305 - 311
  • [50] Analysis of Tumor Motion using Four-dimensional (4D) CT in Patients undergoing Stereotactic Body Radiation Therapy (SBRT) or Hypofractionated 3D Conformal Radiation Therapy (3D-CRT) for Stage I Non-small Cell Lung Cancer
    Chopra, R. R.
    Hahn, S. S.
    Shah, H. R.
    Liu, L.
    Bogart, J. A.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2009, 75 (03): : S469 - S470