Calculating the predicted retinal thickness from spectral domain and time domain optical coherence tomography - comparison of different methods

被引:9
|
作者
Tan, Colin S. [1 ,2 ]
Li, Kelvin Z. [1 ]
Lim, Tock Han [1 ,2 ]
机构
[1] Tan Tock Seng Hosp, Dept Ophthalmol, Singapore 308433, Singapore
[2] Natl Healthcare Grp Eye Inst, Fundus Image Reading Ctr, Singapore, Singapore
关键词
Optical coherence tomography; Central retinal thickness; Spectral domain OCT; Time domain OCT; DIABETIC MACULAR EDEMA; NORMAL EYES; STRATUS OCT; INSTRUMENTS; DEGENERATION; RANIBIZUMAB; BOUNDARY; ADULTS;
D O I
10.1007/s00417-014-2672-9
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
To compare the accuracy of different methods of calculating predicted central retinal thickness values in order to allow comparison between results of spectral-domain optical coherence tomography (SD-OCT) and time-domain OCT (TD-OCT) devices. In a prospective cohort study, 100 consecutive healthy individuals without ocular disease underwent sequential scanning with SD-OCT (Spectralis OCT) and TD-OCT (Stratus OCT). A group of 60 eyes was used to generate the conversion equations, which were tested on the remaining 140 eyes. Four equations were used: 1. Mean difference between SD-OCT and TD-OCT; 2. Multiplying a ratio by the original retinal thickness; 3. Linear regression analysis using retinal thickness; and 4. Regression analysis using retinal thickness and spherical equivalent. All four methods were used to calculate predicted SD-OCT values from TD-OCT measurements, and vice versa. For all four equations, the predicted SD-OCT central retinal thickness values were similar to the actual SD-OCT, with mean difference ranging from 0.78 to 1.01 mu m, and intraclass correlation coefficients > 0.88. Both regression equations and mean difference showed greater accuracy, with variation between calculated and actual retinal thickness values a parts per thousand currency sign5 mu m in 60 % of eyes. In contrast, the ratio method was less accurate, with 15.8 % of eyes showing differences > 15 mu m. Similar results were found for predicted TD-OCT values. Several methods can be used to convert central retinal thickness values from SD-OCT to the predicted TD-OCT value, or vice versa, with high degrees of accuracy and reliability. These methods may allow comparison of OCT values from SD-OCT and TD-OCT devices in clinical trials and standard patient care.
引用
收藏
页码:1491 / 1499
页数:9
相关论文
共 50 条
  • [1] Calculating the predicted retinal thickness from spectral domain and time domain optical coherence tomography – comparison of different methods
    Colin S. Tan
    Kelvin Z. Li
    Tock Han Lim
    Graefe's Archive for Clinical and Experimental Ophthalmology, 2014, 252 : 1491 - 1499
  • [2] Agreement of predicted and measured retinal nerve fiber layer thickness from spectral domain and time domain optical coherence tomography
    Laemmer, Robert
    Schrems, Wolfgang A.
    Schrems-Hoesl, Laura M.
    Horn, Folkert K.
    Kruse, Friedrich E.
    Mardin, Christian Y.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2015, 56 (07)
  • [3] Predicted and Measured Retinal Nerve Fiber Layer Thickness From Time-Domain Optical Coherence Tomography Compared With Spectral-Domain Optical Coherence Tomography
    Schrems, Wolfgang A.
    Schrems-Hoesl, LauraM.
    Bendschneider, Delia
    Mardin, Christian Y.
    Laemmer, Robert
    Kruse, Friedrich E.
    Horn, Folkert K.
    JAMA OPHTHALMOLOGY, 2015, 133 (10) : 1135 - 1143
  • [4] Comparison of Time Domain and Spectral Domain Optical Coherence Tomography in Retinal Nerve Fiber Layer Thickness Measurements
    Bhartiya, S.
    Kumar, M.
    Kumar, V.
    Khanduja, S.
    Mishra, S. K.
    Dada, T.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2010, 51 (13)
  • [5] Comparison of Spectral Domain Retinal Nerve Fiber Layer Thickness and Agreement with Time Domain Optical Coherence Tomography
    Seibold, L.
    Mandava, N.
    Kahook, M. Y.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2010, 51 (13)
  • [6] Comparison of Macular Thickness Measurements between Time Domain and Spectral Domain Optical Coherence Tomography
    Leung, Christopher Kai-shun
    Cheung, Carol Yim-lui
    Weinreb, Robert N.
    Lee, Gary
    Lin, Dusheng
    Pang, Chi Pui
    Lam, Dennis S. C.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2008, 49 (11) : 4893 - 4897
  • [7] Comparison of Retinal Nerve Fiber Layer Thickness Measured by Time Domain and Spectral Domain Optical Coherence Tomography in Optic Neuritis
    Rebolleda, G.
    Garcia-Garcia, A.
    Kim, H. -R. Won
    Munoz-Negrete, F. J.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2010, 51 (13)
  • [8] COMPARING RETINAL THICKNESS MEASUREMENTS FROM CIRRUS SPECTRAL DOMAIN- AND STRATUS TIME DOMAIN-OPTICAL COHERENCE TOMOGRAPHY
    Geitzenauer, Wolfgang
    Kiss, Christopher G.
    Durbin, Mary K.
    Abunto, Maria Teresa A.
    Callan, Thomas M.
    Stetson, Paul F.
    Wieland, Mark R.
    Bressler, Neil M.
    Gregori, Giovanni
    Schmidt-Erfurth, Ursula M.
    RETINA-THE JOURNAL OF RETINAL AND VITREOUS DISEASES, 2010, 30 (04): : 596 - 606
  • [9] Comparison of retinal nerve fibre layer measurements from time domain and spectral domain optical coherence tomography systems
    Johnson, Davin E.
    El-Defrawy, Sherif R.
    Almeida, David R. P.
    Campbell, Robert J.
    CANADIAN JOURNAL OF OPHTHALMOLOGY-JOURNAL CANADIEN D OPHTALMOLOGIE, 2009, 44 (05): : 562 - 566
  • [10] Comparison of Retinal Nerve Fiber Layer Thickness Measurements and Diagnostic Accuracy Between Spectral Domain and Time Domain Optical Coherence Tomography
    Baleanu, D.
    Tornow, R. P.
    Horn, F. K.
    Laemmer, R.
    Kruse, F. E.
    Mardin, C. Y.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2010, 51 (13)