Respiration Average CT for Myocardial Perfusion SPECT/CT Attenuation Correction

被引:0
|
作者
Mok, Greta S. P. [1 ]
Zhang, Duo [1 ]
Ho, Cobie Y. T. [1 ]
机构
[1] Univ Macau, Fac Sci & Technol, Dept Elect & Comp Engn, Macau, Peoples R China
关键词
MISREGISTRATION;
D O I
暂无
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
Previously we proposed interpolated averaged CT (IACT) as a low dose alternate of cine average CT (CACT) for improved PET/CT attenuation correction (AC) in oncology and cardiology applications. This study aims to evaluate the effectiveness of both average CT protocols in myocardial perfusion SPECT/CT. We simulated a patient injected with Tc-99m-sestamibi using the digital 4D Extended Cardiac Torso (XCAT) phantom. We modeled the respiratory motion of 2, 3 and 4 cm with period of 5.9 s. The average attenuation and activity maps represented CACT and static SPECT, while the attenuation maps of end-inspiration and end-expiration represented 2 helical CTs (HCT-in and HCT-ex). The IACT was obtained by averaging the HCT-in, HCT-ex and the interpolated phases between them generated by B-spline method. Sixty noise free and realistic noisy projections with attenuation modeling were generated from RAO to LPO positions using an analytical projector to model a low energy high resolution parallel-hole collimator. Data were reconstructed with different AC maps (CACT, HCTs and IACT) using OS-EM method with up to 200 updates. Polar plots were generated from the short-axis images and 17-segments were drawn on the plots. Relative difference (RD) of the average intensity was computed for each segment using the original phantom as the reference. Slight artifacts can be observed in the reconstructed images and polar plots using the HCTs AC. For motion amplitude = 2 cm, the maximum RD for CACT, IACT, HCT-in and HCT-ex were 0.7%, 2.3%, 6.1% and 8.0% respectively. The RD of the HCTs notably deviated from the phantom in the basal inferolateral and anterolateral regions especially for higher motion amplitudes. Our findings are consistent with our former results of cardiac PET/CT. We conclude that CACT and IACT have the potential to reduce respiratory artifacts and improve quantitation in myocardial perfusion SPECT/CT. The performance of IACT was comparable to CACT with reduced radiation dose.
引用
收藏
页数:2
相关论文
共 50 条
  • [1] Respiratory average CT for attenuation correction in myocardial perfusion SPECT/CT
    Duo Zhang
    Bang-Hung Yang
    Nien Yun Wu
    Greta Seng Peng Mok
    Annals of Nuclear Medicine, 2017, 31 : 172 - 180
  • [2] Respiratory average CT for attenuation correction in myocardial perfusion SPECT/CT
    Zhang, Duo
    Yang, Bang-Hung
    Wu, Nien Yun
    Mok, Greta Seng Peng
    ANNALS OF NUCLEAR MEDICINE, 2017, 31 (02) : 172 - 180
  • [3] CT-attenuation correction in myocardial perfusion SPECT using a hybrid SPECT/CT
    Namdar, M
    Siegrist, PT
    Koepfli, P
    Tschuetscher, P
    Hany, TF
    Kaufmann, PA
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2004, 31 : S261 - S261
  • [4] Impact of CT Attenuation Correction in SPECT Myocardial Perfusion Imaging
    Vlachou, F.
    Nikaki, A.
    Gogos, K.
    Tsiakas, E.
    Papoutsani, D.
    Giannis, D.
    Gogou, L.
    Prassopoulos, V.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2011, 38 : S317 - S317
  • [5] Hybrid SPECT/CT for Attenuation Correction of Stress Myocardial Perfusion Imaging
    Huang, Rui
    Li, Fanglan
    Zhao, Zhen
    Liu, Bin
    Ou, Xiaohong
    Tian, Rong
    Li, Lin
    CLINICAL NUCLEAR MEDICINE, 2011, 36 (05) : 344 - 349
  • [6] Attenuation Correction Methods for Dual Gated Myocardial Perfusion SPECT/CT
    Zhang, Qi
    Zhang, Duo
    Mok, Greta S. P.
    2017 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2017,
  • [7] Interpretation of myocardial perfusion SPECT with CT-based attenuation correction
    Ansheles, A.
    Martirosyan, L.
    Sergienko, I.
    Sergienko, V.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2015, 42 : S527 - S528
  • [8] The Role of the Attenuation Correction by ECG-GATED Myocardial Perfusion SPECT/CT
    Radacsi, A.
    Olbrich, Z.
    Balogh, I.
    Ronaszeki, A.
    Ronaszeki, A.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2012, 39 : S538 - S539
  • [9] Attenuation correction in myocardial perfusion SPECT/CT: Effects of misregistration and value of reregistration
    Goetze, Sibyll
    Brown, Tracy L.
    Lavely, William C.
    Zhang, Zhe
    Bengel, Frank M.
    JOURNAL OF NUCLEAR MEDICINE, 2007, 48 (07) : 1090 - 1095
  • [10] CT attenuation correction of spect myocardial perfusion scintigraphy improves diagnostic accuracy
    Wright, G.
    Cockburn, K.
    Davies, G.
    Avery, G.
    Tweddel, A.
    HEART, 2007, 93 : A97 - A97