Comparative studies on the electrogenerated chemiluminescent and amperometric behavior of the Ru(bpy)32+ system on a paraffin-impregnated graphite electrode and a glassy carbon electrode

被引:9
|
作者
Li, F [1 ]
Lin, XQ [1 ]
Cui, H [1 ]
机构
[1] Univ Sci & Technol China, Dept Chem, Hefei 230026, Anhui, Peoples R China
来源
JOURNAL OF ELECTROANALYTICAL CHEMISTRY | 2002年 / 534卷 / 01期
基金
中国国家自然科学基金;
关键词
paraffin-impregnated graphite electrode; glassy carbon electrode; Ru(bpy)(3)(2+); electrochemical techniques; electrochemiluminescence;
D O I
10.1016/S0022-0728(02)01146-4
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The electrogenerated chemiluminescent (ECL) and amperometric, behavior of Ru(bpy)(3)(2+) system on a paraffin-impregnated graphite electrode (PIGE) and a glassy carbon electrode (GCE) was studied by different electrochemical techniques. Under conventional cyclic voltammetric (CV) conditions, two anodic ECL peaks (EP1 and EP2) (vs. SCE) were observed at 1.18 and 1.37 V for a PIGE, and at 1.20 and 1.44 V for a GCE. The EP1 normally occurred, but not the EP2. A complicated mechanism was involved in the formulation of EP2. A detection limit as low as 1 x 10(-9) mol l(-1) of C2O42- was obtained on the PIGE by the CV method at 100 mV s(-1). Strong ECL signals were found on both electrodes in either an oxalate-containing aqueous solution or an organic solution when a cyclic square wave (CSW), between two suitable potentials was used. However, the GCE showed higher reproducibility than the PIGE for continuous CSW (n = 10) measurements. Chronoamperometry was also applied by using a potential step from 0.15 to 1.85 V. It took 389 ms on a PIGE and 837 ms on a GCE to reach each maximal ECL intensity. (C) 2002 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:91 / 98
页数:8
相关论文
共 36 条
  • [21] Electrochemiluminescence of the Ru(bpy)32+/S2O82-system in purely aqueous solution at carbon paste electrode
    Xu, GB
    Dong, SJ
    ELECTROANALYSIS, 2000, 12 (08) : 583 - 587
  • [22] A novel electrochemiluminescence sensor based on Ru(bpy)32+ immobilized by graphene on glassy carbon electrode surface via in situ wet-chemical reaction
    Gao, Wenhua
    Chen, Yunsheng
    Xi, Jing
    Zhang, An
    Chen, Yaowen
    Lu, Fushen
    Chen, Zhanguang
    SENSORS AND ACTUATORS B-CHEMICAL, 2012, 171 : 1159 - 1165
  • [23] Electrochemical behavior and adsorptive stripping voltammetric determination of quercetin at multi-wall carbon nanotubes-modified paraffin-impregnated graphite disk electrode
    Jin, Guan-Ping
    He, Jian-Bo
    Rui, Ze-Bao
    Meng, Fan-Shun
    ELECTROCHIMICA ACTA, 2006, 51 (21) : 4341 - 4346
  • [24] A catalytic nanostructured cobalt oxide electrode enables positive potential operation for the cathodic electrogenerated chemiluminescence of Ru(bpy)32+ with dramatically enhanced intensity
    Guo, Weiling
    E, Yifeng
    Gao, Li
    Fan, Louzhen
    Yang, Shihe
    CHEMICAL COMMUNICATIONS, 2010, 46 (08) : 1290 - 1292
  • [25] Potential-resolved electrochemiluminescence of Ru(bpy)32+/C2O42- system on gold electrode
    Li, F
    Cui, H
    Lin, XQ
    LUMINESCENCE, 2002, 17 (02) : 117 - 122
  • [26] A Novel Electrochemiluminescence Modified Glasss Carbon Electrode Based on Carboxylated Acetylene Black/Ru(bpy)32+/Nafion for Detection of Isoniazid
    Jiang, Jing-yi
    Li, Qingyi
    Wang, Wen-chang
    Chen, Xiao-hui
    Chen, Zhi-dong
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2018, 13 (01): : 587 - 597
  • [27] New capillary electrophoresis-electrochemiluminescence detection system equipped with an electrically heated Ru(bpy)32+/multi-wall-carbon-nanotube paste electrode
    Chen, Yiting
    Lin, Zhenyu
    Chen, Jinhua
    Sun, Jianjun
    Zhang, Lan
    Chen, Guonan
    JOURNAL OF CHROMATOGRAPHY A, 2007, 1172 (01) : 84 - 91
  • [28] Homogenous electrogenerated chemiluminescence immunoassay for human immunoglobulin G using N-(aminobutyl)-N-ethylisoluminol as luminescence label at gold nanoparticles modified paraffin-impregnated graphite electrode
    Qi, Honglan
    Zhang, Yi
    Peng, Yage
    Zhang, Chengxiao
    TALANTA, 2008, 75 (03) : 684 - 690
  • [29] An Electrochemiluminescent Detector Based on Multi-Wall-Carbon-Nanotube/Nafion/Ru(bpy)32+ Composite Film Modified Heated-Electrode
    Chen, Yiting
    Jiang, Yingyan
    Lin, Zhenyu
    Sun, Jianjun
    Zhang, Lan
    Chen, Guonan
    JOURNAL OF NANOSCIENCE AND NANOTECHNOLOGY, 2009, 9 (04) : 2303 - 2309
  • [30] Determination of carbamates in nature water based on the enhancement of electrochemiluminescent of Ru(bpy)32+ at the multi-wall carbon nanotube-moditied electrode
    Lin, Zhenyu
    Chen, Guonan
    TALANTA, 2006, 70 (01) : 111 - 115