Patient-specific Computer Simulation: An Emerging Technology for Guiding the Transcatheter Treatment of Patients with Bicuspid Aortic Valve

被引:7
|
作者
Dowling, Cameron [1 ,2 ,3 ,6 ]
Gooley, Robert [1 ,2 ,3 ]
Mccormick, Liam [1 ,2 ,3 ]
Firoozi, Sami [4 ,5 ]
Brecker, Stephen J. [4 ,5 ]
机构
[1] Monash Univ, MonashHeart, Melbourne, Australia
[2] Monash Univ, Monash Hlth, Melbourne, Australia
[3] Monash Univ, Monash Cardiovasc Res Ctr, Melbourne, Australia
[4] St Georges Univ London, Cardiol Clin Acad Grp, London, England
[5] St Georges Univ Hosp NHS Fdn Trust, London, England
[6] MonashHeart, 246 Clayton Rd, Clayton, Vic 3168, Australia
关键词
Aortic valve stenosis; bicuspid aortic valve; computer simulation; finite element analysis; transcatheter aortic valve replacement; heart valve prosthesis implantation;
D O I
10.15420/icr.2021.09
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Transcatheter aortic valve implantation (TAVI) is increasingly being used to treat younger, lower-risk patients, many of whom have bicuspid aortic valve (BAV). As TAVI begins to enter these younger patient cohorts, it is critical that clinical outcomes from TAVI in BAV are matched to those achieved by surgery. Therefore, the identification of patients who, on an anatomical basis, may not be suitable for TAVI, would be desirable. Furthermore, clinical outcomes of TAVI in BAV might be improved through improved transcatheter heart valve sizing and positioning. One potential solution to these challenges is patient-specific computer simulation. This review presents the methodology and clinical evidence surrounding patient-specific computer simulation of TAVI in BAV.
引用
收藏
页数:6
相关论文
共 50 条
  • [31] Patient-Specific Computational Modeling of Transcatheter Aortic Valve Implantation
    Ge, Liang
    Azadani, Ali
    Chitsaz, Sam
    Mookhoek, Aart
    Wisneski, Andrew
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2012, 60 (17) : B265 - B265
  • [32] Validating In Silico and In Vitro Patient-Specific Structural and Flow Models with Transcatheter Bicuspid Aortic Valve Replacement Procedure
    Salwa B. Anam
    Brandon J. Kovarovic
    Ram P. Ghosh
    Matteo Bianchi
    Ashraf Hamdan
    Rami Haj-Ali
    Danny Bluestein
    Cardiovascular Engineering and Technology, 2022, 13 : 840 - 856
  • [33] Transcatheter aortic valve replacement in bicuspid aortic valve patients
    Fernando Nascimento Ferreira, F.
    Rodrigues, I.
    Figueiredo, M.
    Teixeira, B.
    Albuquerque, F.
    Carvalheiro, R.
    Mendonca, T.
    Grazina, A.
    Cacela, D.
    Ramos, R.
    Fiarresga, A.
    Cruz Ferreira, R.
    EUROPEAN JOURNAL OF HEART FAILURE, 2024, 26 : 553 - 553
  • [34] Patient-specific computer modelling to predict anatomical risk factors preventing post transcatheter aortic valve implantation coronary re-access in bicuspid aortic valve; a modelling study
    Dargan, J.
    Rocatello, G.
    Weng, Y.
    Khan, F.
    Firoozi, S.
    Dowling, C.
    Brecker, S.
    EUROPEAN HEART JOURNAL, 2023, 44
  • [35] Patient-specific simulation of transcatheter aortic valve replacement: impact of deployment options on paravalvular leakage
    Bianchi, Matteo
    Marom, Gil
    Ghosh, Ram P.
    Rotman, Oren M.
    Parikh, Puja
    Gruberg, Luis
    Bluestein, Danny
    BIOMECHANICS AND MODELING IN MECHANOBIOLOGY, 2019, 18 (02) : 435 - 451
  • [36] Patient-specific simulation of transcatheter aortic valve replacement: impact of deployment options on paravalvular leakage
    Matteo Bianchi
    Gil Marom
    Ram P. Ghosh
    Oren M. Rotman
    Puja Parikh
    Luis Gruberg
    Danny Bluestein
    Biomechanics and Modeling in Mechanobiology, 2019, 18 : 435 - 451
  • [37] Comparative finite element analysis of patient-specific tricuspid and bicuspid aortic valve
    Djorovic, Smiljana
    Filipovic, Nenad
    Milosavljevic, Aleksandar
    Velicki, Lazar
    2017 IEEE 17TH INTERNATIONAL CONFERENCE ON BIOINFORMATICS AND BIOENGINEERING (BIBE), 2017, : 563 - 567
  • [38] Quantitative in silico analysis for patient-specific annuloplasty in bicuspid aortic valve regurgitation
    Ju, Jiayi
    Cai, Yunhan
    Gao, Hao
    Yang, Tianyang
    Wang, Shengzhang
    JOURNAL OF THE MECHANICAL BEHAVIOR OF BIOMEDICAL MATERIALS, 2025, 162
  • [39] Simulation of Transcatheter Aortic Valve Replacement in patient-specific aortic roots: effect of crimping and positioning on device performance
    Bianchi, Matteo
    Ghosh, Ram P.
    Marom, Gil
    Slepian, Marvin J.
    Bluestein, Danny
    2015 37TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2015, : 282 - 285
  • [40] Simulation study of transcatheter heart valve implantation in patients with stenotic bicuspid aortic valve
    Pasta, Salvatore
    Cannata, Stefano
    Gentile, Giovanni
    Di Giuseppe, Marzio
    Cosentino, Federica
    Pasta, Francesca
    Agnese, Valentina
    Bellavia, Diego
    Raffa, Giuseppe M.
    Pilato, Michele
    Gandolfo, Caterina
    MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 2020, 58 (04) : 815 - 829