Measuring blood volume with fluorescent-labeled hydroxyethyl starch

被引:15
|
作者
Thomas, E
Jones, G
de Souza, P
Wardrop, C
Wusteman, F
机构
[1] Univ Wales Coll Med, Dept Haematol, Cardiff CF4 4XN, S Glam, Wales
[2] Cardiff Univ, Sch Mol & Med Biosci, Cardiff, S Glam, Wales
关键词
hydroxyethyl starch; hypovolemia; blood volume; plasma volume; fluorescent; dilution technique;
D O I
10.1097/00003246-200003000-00004
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Objectives To develop and evaluate a method for measuring brood volume using the dilution of a fluorescent-labeled hydroxyethyl starch. Design: Laboratory and clinical investigation. Setting: Biochemistry laboratory at the University of Cardiff, Hematology clinic, surgical ward and intensive care unit of the University Hospital of Wales. Patients: Seventeen patients with suspected polycythemia. Eight patients who had undergone major surgery and/or were receiving intensive postoperative care. Interventions: All surgical and postoperative care was provided by clinicians not involved in the study. Patients with suspected polycythemia were referred for blood volume measurement using labeled albumin and red blood cells. Measurement and Main Results:A proprietary brand of hydroxyethyl starch (Elohaes) was labeled with fluorescein isothiocyanate. Dilution of this compound in vivo was used for measuring blood volume, and the results were compared with those obtained using radiolabeIed albumin and the considered criterion, radiolabeled red cells. The elimination of the labeled starch follows the same progress as that of the parent compound, indicating that the fluorescent tag is stable in vivo. The volume of distribution of the labeled starch is 2.5 mL/kg lower than that for labeled albumin (p =.05), Brood volume, measured from the dilution of fluorescent starch, is lower (4.9 mL/kg) than that measured with albumin (p =.048) but higher (6.61 mL/kg) than that measured with red blood cells (p =.0007). This latter difference may be even smaller at marginally higher doses of the fluorescent starch. Conclusion: These data support the view that hydroxyethyl starch provides a valid alternative to red cell labels as a means of calculating blood volume in patients. Labeling the starch with a fluorescent marker makes the assay procedure more sensitive and infinitely easier. The dose required is not high enough to affect the hemodynamic status of the patient.
引用
收藏
页码:627 / 631
页数:5
相关论文
共 50 条
  • [41] Fluorescent Guided Sentinel Lymph Mapping of the Oral Cavity with Fluorescent-Labeled Tilmanocept
    Guo, Theresa
    Jang, Sophie S.
    Ogawa, Ryotaro
    Davis, Morgan
    Ashworth, Edward
    Barback, Christopher V.
    Hall, David J.
    Vera, David R.
    LARYNGOSCOPE, 2024, 134 (03): : 1299 - 1307
  • [42] Effect of phosphorylation on the structure and oligomeric state of fluorescent-labeled phospholamban
    Li, M
    Bennett, R
    Reddy, L
    Silva, ND
    Jones, LR
    Thomas, DD
    BIOPHYSICAL JOURNAL, 1997, 72 (02) : THAM3 - THAM3
  • [43] Volume Therapy: Hydroxyethyl Starch or Saline?
    Feldmann, Christoph
    DEUTSCHE MEDIZINISCHE WOCHENSCHRIFT, 2013, 138 (03) : 66 - 66
  • [44] DYE DISTRIBUTION IN FLUORESCENT-LABELED LATEX PREPARED BY EMULSION POLYMERIZATION
    SOSNOWSKI, S
    FENG, JR
    WINNIK, MA
    JOURNAL OF POLYMER SCIENCE PART A-POLYMER CHEMISTRY, 1994, 32 (08) : 1497 - 1505
  • [45] PREPARATION AND CHROMATOGRAPHIC USE OF 5'-FLUORESCENT-LABELED DNA PROBES
    TOUS, G
    FAUSNAUGH, J
    VIEIRA, P
    STEIN, S
    JOURNAL OF CHROMATOGRAPHY, 1988, 444 : 67 - 77
  • [46] Detection of Nitroaromatic Explosives Using a Fluorescent-Labeled Imprinted Polymer
    Stringer, R. Cody
    Gangopadhyay, Shubhra
    Grant, Sheila A.
    ANALYTICAL CHEMISTRY, 2010, 82 (10) : 4015 - 4019
  • [47] Synthesis of Fluorescent-Labeled Nucleotides for Labeling of Isothermal Amplification Products
    Shershov, V. E.
    Lapa, S. A.
    Levashova, A. I.
    Shishkin, I. Yu.
    Shtylev, G. F.
    Shekalova, E. Yu.
    Vasiliskov, V. A.
    Zasedatelev, A. S.
    Kuznetsova, V. E.
    Chudinov, A. V.
    RUSSIAN JOURNAL OF BIOORGANIC CHEMISTRY, 2023, 49 (05) : 1151 - 1158
  • [48] MONITORING OF FLUORESCENT-LABELED MAIN PROGESTERONE METABOLITE IN MARMOSET MONKEYS
    HEGER, W
    NEUBERT, D
    JOURNAL OF LIQUID CHROMATOGRAPHY, 1988, 11 (13): : 2771 - 2787
  • [49] The synthesis and properties of fluorescent-labeled detergents, analogues of glycocholic acid
    Grechishnikova, IV
    Khaznaferova, ID
    Kalinin, SV
    Barsukov, LI
    Molotkovsky, JG
    BIOORGANICHESKAYA KHIMIYA, 2000, 26 (09): : 693 - 702
  • [50] A fluorescent-labeled oligopeptide for monitoring PKA-mediated phosphorylation
    Ohuchi, Y
    Katayama, Y
    Maeda, M
    ANALYST, 2000, 125 (11) : 1905 - 1907