Reduction of Motion Artifacts in Carotid MRI Using Free-Induction Decay Navigators

被引:13
|
作者
Dyverfeldt, Petter [1 ]
Deshpande, Vibhas S. [2 ]
Kober, Tobias [3 ]
Krueger, Gunnar [3 ]
Saloner, David [1 ,4 ]
机构
[1] Univ Calif San Francisco, Dept Radiol & Biomed Imaging, San Francisco, CA 94143 USA
[2] Siemens Med Solut USA Inc, San Francisco, CA USA
[3] Siemens Healthcare Sector IM S AW, Adv Clin Imaging Technol, Lausanne, Switzerland
[4] Vet Affairs Med Ctr, San Francisco, CA 94121 USA
基金
美国国家卫生研究院;
关键词
carotid MRI; motion compensation; FID navigator; motion suppression; carotid artery disease; atherosclerosis; TURBO SPIN-ECHO; WALL MRI; ATHEROSCLEROTIC PLAQUE; MAGNETIC-RESONANCE; ARTERIES; TSE; SUPPRESSION; STENOSIS; SEQUENCE; RISK;
D O I
10.1002/jmri.24389
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To develop a framework for prospective free-induction decay (FID)-based navigator gating for suppression of motion artifacts in carotid magnetic resonance imaging (MRI) and to assess its capability in vivo. Materials and Methods: An FID-navigator, comprising a spatially selective low flip-angle sinc-pulse followed by an analog-to-digital converter (ADC) readout, was added to a conventional turbo spin-echo (TSE) sequence. Real-time navigator processing delivered accept/reject-and-reacquire decisions to the sequence. In this Institutional Review Board (IRB)-approved study, seven volunteers were scanned with a 2D T2-weighted TSE sequence. A reference scan with volunteers instructed to minimize motion as well as nongated and gated scans with volunteers instructed to perform different motion tasks were performed in each subject. Multiple image quality measures were employed to quantify the effect of gating. Results: There was no significant difference in lumen-to-wall sharpness (2.3 +/- 0.3 vs. 2.3 +/- 0.4), contrast-to-noise ratio (CNR) (9.0 +/- 2.0 vs. 8.5 +/- 2.0), or image quality score (3.1 +/- 0.9 vs. 2.6 +/- 1.2) between the reference and gated images. For images acquired during motion, all image quality measures were higher (P < 0.05) in the gated compared to nongated images (sharpness: 2.3 +/- 0.4 vs. 1.8 +/- 0.5, CNR: 8.5 +/- 2.0 vs. 7.2 +/- 2.0, score: 2.6 +/- 1.2 vs. 1.8 +/- 1.0). Conclusion: Artifacts caused by the employed motion tasks deteriorated image quality in the nongated scans. These artifacts were alleviated with the proposed FID-navigator.
引用
收藏
页码:214 / 220
页数:7
相关论文
共 50 条
  • [41] FREE-INDUCTION DECAY SHAPE CHANGE BY DEFECT-INDUCED QUADRUPOLE INTERACTION
    CUEMAN, MK
    HESTER, RK
    SHER, A
    SOEST, JF
    LOWE, IJ
    PHYSICAL REVIEW B, 1975, 12 (09): : 3610 - 3617
  • [43] CALCULATION OF MOMENTS OF NMR ABSORPTION LINES FROM FREE-INDUCTION DECAY CURVES
    PARKER, GW
    JOURNAL OF CHEMICAL PHYSICS, 1973, 58 (08): : 3274 - 3280
  • [44] Time-resolved phase spectroscopy from femtosecond free-induction decay
    Luo, Q
    Yu, XY
    Qiu, ZR
    Li, WL
    Li, Q
    Zhou, JY
    APPLIED PHYSICS B-LASERS AND OPTICS, 2000, 70 (01): : 53 - 56
  • [45] LOCAL-FIELD-INDUCED MULTIPLE-PULSE FREE-INDUCTION DECAY
    WILSON, RJ
    HAHN, EL
    PHYSICAL REVIEW B, 1983, 27 (07): : 4129 - 4134
  • [46] Free-induction decay after a pulse saturation for systems with noncorrelated frequency exchange
    Malinovsky, VS
    Szabo, A
    PHYSICAL REVIEW A, 1997, 55 (05) : 3826 - 3831
  • [47] Optical free-induction decay of laser-cooled Rb-85
    Toyoda, K
    Takahashi, Y
    Ishikawa, K
    Yabuzaki, T
    PHYSICAL REVIEW A, 1997, 56 (02): : 1564 - 1568
  • [48] FREE-INDUCTION DECAY GENERATION OF 10.6 MU-M SUBNANOSECOND PULSES
    FELDMAN, BJ
    FISHER, RA
    MCLELLAN, EJ
    THOMAS, SJ
    OPTICS COMMUNICATIONS, 1976, 18 (01) : 72 - 72
  • [49] Accuracy and Precision of Head Motion Information in Multi-Channel Free Induction Decay Navigators for Magnetic Resonance Imaging
    Babayeva, Maryna
    Kober, Tobias
    Knowles, Benjamin
    Herbst, Michael
    Meuli, Reto
    Zaitsev, Maxim
    Krueger, Gunnar
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2015, 34 (09) : 1879 - 1889
  • [50] Prospective motion correction in kidney MRI using FID navigators
    Ariyurek, Cemre
    Wallace, Tess E.
    Kober, Tobias
    Kurugol, Sila
    Afacan, Onur
    MAGNETIC RESONANCE IN MEDICINE, 2023, 89 (01) : 276 - 285