The characterization of macrophages and osteoclasts in tissues harvested from revised total hip prostheses

被引:0
|
作者
Chun, L
Yoon, J
Song, Y
Huie, P
Regula, D
Goodman, S
机构
[1] Stanford Univ, Med Ctr, Div Orthopaed Surg, Stanford, CA 94305 USA
[2] Stanford Univ, Med Ctr, Dept Pathol, Stanford, CA 94305 USA
来源
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH | 1999年 / 48卷 / 06期
关键词
macrophage; osteoclast; cellular differentiation; total hip replacement; immunohistochemistry;
D O I
10.1002/(SICI)1097-4636(1999)48:6<899::AID-JBM20>3.0.CO;2-E
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The differentiation and maturation of macrophages and osteoclasts at the prosthetic interface in cases of implant loosening are poorly understood. Using histochemical and immunohistochemical staining methods, we compare macrophage differentiation in tissues from revised hip replacements in patients with specific clinical-radiological appearances. Periprosthetic tissues were harvested from 12 cemented acetabular and 12 cemented femoral components in 24 patients undergoing revision hip replacement. The prostheses mere all radiographically and clinically loose. Six acetabular and six femoral components demonstrated radiographic ballooning osteolysis. Serial 6 mu m frozen sections of the periprosthetic tissues were processed with hematoxylin and eosin for general tissue morphology, and analyzed for the presence of tartrate resistant acid phosphatase (TRAP, an osteoclast marker). Immunoperoxidase staining using monoclonal antibodies to CD68 (macrophages and osteoclasts) and CD51 (the alpha chain of the vitronectin receptor, an osteoclast marker) was also performed. Approximately 8-30% of the total cells in the tissues were positive for TRAP and the vitronectin receptor, and comprised a subset of the CD68 positive macrophages and macrophage polykaryons. However, there were no statistically significant differences between specific groups (femoral vs. acetabular, osteolysis vs. no osteolysis) for the numbers or percentages of macrophages or osteoclast-like cells. Once prosthetic loosening has occurred, few differences in the macrophage-osteoclast profile of tissues from different periprosthetic locations, with and without osteolysis, are noted. This suggests a final common biologic pathway for periprosthetic bone resorption, once implant loosening has transpired. (C) 1999 John Wiley & Sons, Inc.
引用
收藏
页码:899 / 903
页数:5
相关论文
共 50 条
  • [21] Metallic debris from metal-on-metal total hip arthroplasty regulates periprosthetic tissues
    Lohmann, Christoph H.
    Singh, Gurpal
    Willert, Hans-Georg
    Buchhorn, Gottfried H.
    WORLD JOURNAL OF ORTHOPEDICS, 2014, 5 (05): : 660 - 666
  • [22] Metal wear particle characterization from metal on metal total hip replacements: Transmission electron microscopy study of periprosthetic tissues and isolated particles
    Doorn, PF
    Campbell, PA
    Worrall, J
    Benya, PD
    McKellop, HA
    Amstutz, HC
    JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 1998, 42 (01): : 103 - 111
  • [23] Isolation, Characterization, and Purification of Macrophages from Tissues Affected by Obesity-related Inflammation
    Allen, Joselyn N.
    Dey, Adwitia
    Nissly, Ruth
    Fraser, James
    Yu, Shan
    Balandaram, Gayathri
    Peters, Jeffrey M.
    Hankey-Giblin, Pamela A.
    JOVE-JOURNAL OF VISUALIZED EXPERIMENTS, 2017, (122):
  • [24] Polyethylene wear in total hip prostheses: the influence of direction of linear wear on volumetric wear determined from radiographic data
    Kosak, R
    Antolic, V
    Pavlovcic, V
    Kralj-Iglic, V
    Milosev, I
    Vidmar, G
    Iglic, A
    SKELETAL RADIOLOGY, 2003, 32 (12) : 679 - 686
  • [25] Comparative Characterization of Osteoclasts Derived From Murine Bone Marrow Macrophages and RAW 264.7 Cells Using Quantitative Proteomics
    Ng, Andrew Yh
    Tu, Chengjian
    Shen, Shichen
    Xu, Ding
    Oursler, Merry J.
    Qu, Jun
    Yang, Shuying
    JBMR PLUS, 2018, 2 (06) : 328 - 340
  • [26] Polyethylene wear in total hip prostheses: the influence of direction of linear wear on volumetric wear determined from radiographic data
    R. Košak
    V. Antolič
    V. Pavlovčič
    V. Kralj-Iglič
    I. Milošev
    G. Vidmar
    A. Iglič
    Skeletal Radiology, 2003, 32 : 679 - 686
  • [27] Unstable Total Hip Arthroplasty: Should It Be Revised Using Dual Mobility Implants? A Retrospective Analysis from the RIPO Registry
    Di Martino, Alberto
    Brunello, Matteo
    Bordini, Barbara
    Rossomando, Valentino
    Tassinari, Leonardo
    D'Agostino, Claudio
    Ruta, Federico
    Faldini, Cesare
    JOURNAL OF CLINICAL MEDICINE, 2023, 12 (02)
  • [28] Characterization and comparison of wear debris from failed total hip implants of different types
    Hirakawa, K
    Bauer, TW
    Stulberg, BN
    Wilde, AH
    Secic, M
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1996, 78A (08): : 1235 - 1243
  • [29] Characterization of in vivo wear debris from ceramic-ceramic total hip arthroplasties
    Lerouge, S
    Huk, O
    Yahia, LH
    Sedel, L
    JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 1996, 32 (04): : 627 - 633
  • [30] Histological Characterization of Chromium Orthophosphate Corrosion Products from Modular Total Hip Replacements
    Kung, Michael Shang
    Campbell, Pat
    Markantonis, John
    Knutsen, Ashleen
    Ameri, Bijan
    Park, Sang-Hyun
    Ebramzadeh, Edward
    MODULARITY AND TAPERS IN TOTAL JOINT REPLACEMENT DEVICES, 2015, 1591 : 428 - 439