摘要
Steel fibre reinforced concrete (SFRC) is in many ways a well-known construction material, and its use has gradually increased over the last decades. The mechanical properties of SFRC are well described based on the theories of fracture mechanics. However, knowledge on other material properties, including the electrical resistivity, is sparse. Among others, the electrical resistivity of concrete has an effect on the corrosion process of possible embedded bar reinforcement and transfer of stray current. The present paper provides experimental results concerning the influence of the fibre volume fraction and the moisture content of the SFRC on its electrical resistivity. The electrical resistivity was measured by alternating current (AC) at 126 Hz. Moreover, an analytical model for the prediction of the electrical resistivity of SFRC is presented. The analytical model is capable of predicting the observed correlation between the fibre volume fraction and the electrical resistivity of the composite (the SFRC) for conductive fibres and moisture saturated concrete. This indicates that the steel fibres were conducting when measuring the electrical resistivity by AC at 126 Hz. For partly saturated concrete the model underestimated the influence of the addition of fibres. The results indicate that the addition of steel fibres reduce the electrical resistivity of concrete if the fibres are conductive. This represents a hypothetical case where all fibres are depassivated (corroding) which was created to obtain a conservative estimate on the influence of fibres on the electrical resistivity of concrete. It was observed that within typical ranges of variation the influence of the moisture content on the electrical resistivity was larger than the effect of addition of conductive steel fibres, but also that the relative impact on the electrical resistivity due to conductive steel fibres increased when the moisture content of the concrete was reduced.
引用
收藏
页码:335 / 350
页数:16
相关论文
共 50 条
  • [21] Tensile strength of steel fibre reinforced concrete
    Ghosh, S.
    Bhattacharya, C.
    Ray, S.P.
    [J]. Journal of the Institution of Engineers (India): Civil Engineering Division, 1989, 69 pt 4 : 222 - 227
  • [22] Surface corrosion of steel fibre reinforced concrete
    Balouch, S. U.
    Forth, J. P.
    Granju, J. -L.
    [J]. CEMENT AND CONCRETE RESEARCH, 2010, 40 (03) : 410 - 414
  • [23] WORKABILITY OF STEEL-FIBRE-REINFORCED CONCRETE
    HUGHES, BP
    FATTUHI, NI
    [J]. MAGAZINE OF CONCRETE RESEARCH, 1976, 28 (96) : 157 - 161
  • [24] Steel fibre reinforced concrete flat slabs
    Gossla, Ulrich
    [J]. Beton- und Stahlbetonbau, 2006, 101 (02) : 94 - 102
  • [25] Determination of the distribution of electrical resistivity in reinforced concrete structures using electrical resistivity tomography
    Reichling, K.
    Raupach, M.
    Klitzsch, N.
    [J]. MATERIALS AND CORROSION-WERKSTOFFE UND KORROSION, 2015, 66 (08): : 763 - 771
  • [26] Novel approach for determining the electrical resistivity of reinforced concrete
    Reichling, Kenji
    Asgharzadeh, Amir
    Raupach, Michael
    [J]. BAUTECHNIK, 2014, 91 (11) : 822 - 827
  • [27] Electrical resistivity tomography through reinforced concrete floor
    Yang, Lichun
    Yang, Dikun
    Yuan, Quan
    [J]. NEAR SURFACE GEOPHYSICS, 2024, 22 (01) : 47 - 59
  • [28] Research on the Influences of Resistivity for Steel Fiber Reinforced Concrete
    Lin Longbin
    Lai Xiuying
    [J]. PROCEEDINGS OF THE 2017 2ND INTERNATIONAL SYMPOSIUM ON ADVANCES IN ELECTRICAL, ELECTRONICS AND COMPUTER ENGINEERING (ISAEECE 2017), 2017, 124 : 245 - 249
  • [29] Effect of steel fibre profile on the fracture characteristics of steel fibre reinforced concrete beams
    Anandan, Sivakumar
    Islam, Saiful
    Khan, Roohul Abad
    [J]. JOURNAL OF ENGINEERING RESEARCH, 2019, 7 (02): : 105 - 124
  • [30] A comparative study of steel reinforced concrete and flax fibre reinforced polymer tube confined coconut fibre reinforced concrete beams
    Yan, Libo
    Chouw, Nawawi
    [J]. JOURNAL OF REINFORCED PLASTICS AND COMPOSITES, 2013, 32 (16) : 1155 - 1164