A cadmium-zinc-telluride strip detector for high-energy diffraction applications

被引:0
|
作者
Siddons, DP [1 ]
Camarda, G [1 ]
Kakuno, E [1 ]
机构
[1] Brookhaven Natl Lab, Natl Synchrotron Light Source Dept, Upton, NY 11973 USA
来源
关键词
D O I
暂无
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
As diffraction experiments in materials science move towards using harder x-rays, the need for efficient multidetectors in the form of 1- and 2-D arrays is felt. Silicon technologgy is not suitable for this, and germanium has the complexity of requiring cryogenics. Cadmium Zinc Telluride has emerged as the most promising compound for such applications. We describe our efforts towards providing a 1-D strip detector suitable for high-energy diffraction.
引用
收藏
页码:965 / 968
页数:4
相关论文
共 50 条
  • [21] Cadmium-zinc-telluride SPECT scanners - New perspectives in nuclear cardiology
    Kincl, Vladimir
    Drozdova, Adela
    Vasina, Jiri
    Panovsky, Roman
    Kaminek, Milan
    COR ET VASA, 2015, 57 (03) : E214 - E218
  • [22] FEASIBILITY OF USING CADMIUM-ZINC-TELLURIDE DETECTORS IN ELECTRONICALLY COLLIMATED SPECT
    SINGH, M
    DOTY, FP
    FRIESENHAHN, SJ
    BUTLER, JF
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1995, 42 (04) : 1139 - 1146
  • [23] The efficiency of a novel ultra-fast cadmium-zinc-telluride detector SPECT camera in myocardial perfusion imaging
    Cicekli, M. K.
    Urhan, M.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2012, 39 : S616 - S616
  • [24] Study of a High Resolution, 3-D Positioning Cross-Strip Cadmium Zinc Telluride Detector for PET
    Gu, Yi
    Matteson, James L.
    Skelton, Robert T.
    Deal, Aaron C.
    Stephan, Edwin A.
    Duttweiler, Fred
    Gasaway, Thomas M.
    Levin, Craig S.
    2008 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (2008 NSS/MIC), VOLS 1-9, 2009, : 2871 - +
  • [25] Influence of channel configuration on bandwidth of cadmium zinc telluride detector with a cross-strip pattern
    Li, Mohan
    Abbaszadeh, Shiva
    RADIATION PHYSICS AND CHEMISTRY, 2019, 155 : 213 - 216
  • [26] Cadmium-zinc-telluride, multiple-electrode detectors achieve good energy resolution with high sensitivity at room-temperature
    Digirad Corp, San Diego, United States
    IEEE Trans Nucl Sci, 3 pt 1 (433-437):
  • [27] Cadmium-zinc-telluride, multiple-electrode detectors achieve good energy resolution with high sensitivity at room-temperature
    Lingren, CL
    Apotovsky, B
    Butler, JF
    Conwell, RL
    Doty, FP
    Friesenhahn, SJ
    Oganesyan, A
    Pi, B
    Zhao, S
    1997 IEEE NUCLEAR SCIENCE SYMPOSIUM - CONFERENCE RECORD, VOLS 1 & 2, 1998, : 127 - 131
  • [28] Cadmium-zinc-telluride, multiple-electrode detectors achieve good energy resolution with high sensitivity at room-temperature
    Lingren, CL
    Apotovsky, B
    Butler, JF
    Conwell, RL
    Doty, FP
    Friesenhahn, SJ
    Oganesyan, A
    Pi, B
    Zhao, S
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1998, 45 (03) : 433 - 437
  • [29] Gated tomographic radionuclide angiography using cadmium-zinc-telluride detector gamma camera; comparison to traditional gamma cameras
    Jensen, Maria Maj
    Schmidt, Ulla
    Huang, Chenxi
    Zerahn, Bo
    JOURNAL OF NUCLEAR CARDIOLOGY, 2014, 21 (02) : 384 - 396
  • [30] Brain scan using an ultra fast cadmium-zinc-telluride gamma camera
    Jurgens, Jennifer
    Quang, Eiping
    Hatoum, Reema
    JOURNAL OF NUCLEAR MEDICINE, 2013, 54