Comparison of the Josephson Voltage Standards of the CMI and the BIPM (part of the ongoing BIPM key comparison BIPM.EM-K10.b)

被引:0
|
作者
Solve, S. [1 ]
Chayramy, R. [1 ]
Stock, M. [1 ]
Streit, Jiri [2 ]
Sira, Martin [2 ]
机构
[1] Bur Int Poids & Mesures, F-92312 Sevres, France
[2] Czech Metrol Inst, Lab DC & LF Elect Measurements, Brno 63800, Czech Republic
关键词
D O I
暂无
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
A comparison of the 10 V Josephson array voltage standard of the Bureau International des Poids et Mesures (BIPM) was made with that of the Czech Metrology Institute (CMI), Czech Republic, in February 2011. For this exercise, option B of the comparison protocol was applied for the nominal voltage of 10 V. The BIPM provided a reference voltage for measurement by the CMI using its Josephson standard with its own measuring device (option B of the comparison protocol). The final results are in good agreement within the combined relative standard uncertainty of 10.3 parts in 1010 for the nominal voltage of 10 V.
引用
收藏
页数:23
相关论文
共 50 条
  • [21] Bilateral Comparison of 10 V Standards between the NSAI -NML (Ireland) and the BIPM, February 2016 (part of the ongoing BIPM key comparison BIPM.EM-K11.b)
    Solve, S.
    Chayramy, R.
    Power, O.
    Stock, M.
    [J]. METROLOGIA, 2016, 53
  • [22] Final report on bilateral comparison of 10 kΩ standards (ongoing BIPM key comparison BIPM.EM-K13.b) between the NIMT-Thailand and the BIPM
    Goebel, R.
    Kurupakorn, C.
    Fletcher, N.
    Stock, M.
    [J]. METROLOGIA, 2010, 47
  • [23] Comparison of the INMETRO and NIST Josephson Voltage Standards (part of the ongoing regional key comparison SIM.EM.BIPM-K10.b.1)
    Tang, Yi-hua
    Landim, Regis Pinheiro
    Afonso, Edson
    Ferreira, Vitor
    [J]. METROLOGIA, 2010, 47
  • [24] On-site comparison of Quantum Hall Effect resistance standards of the CMI and the BIPM: ongoing key comparison BIPM.EM-K12
    Gournay, Pierre
    Rolland, Benjamin
    Kucera, Jan
    Vojackova, Lucie
    [J]. METROLOGIA, 2017, 54
  • [25] Bilateral Comparison of 10 pF Capacitance Standards (ongoing BIPM key comparison BIPM.EM-K14.a) between the CMI, Czech Republic and the BIPM, January-July 2009
    Streit, J.
    Fletcher, N.
    [J]. METROLOGIA, 2010, 47
  • [26] Bilateral Comparison of 10 V Standards between the NSAI - NML (Ireland) and the BIPM, March 2015 (part of the ongoing BIPM key comparison BIPM. EM-K11.b)
    Solve, S.
    Chayramy, R.
    Stock, M.
    Power, O.
    [J]. METROLOGIA, 2015, 52
  • [27] Bilateral Comparison of 10 V Standards between the NSAI - NML (Ireland) and the BIPM, February to March 2012 (part of the ongoing BIPM key comparison BIPM.EM-K11.b)
    Power, O.
    Solve, S.
    Chayramy, R.
    Stock, M.
    [J]. METROLOGIA, 2012, 49
  • [28] Bilateral Comparison of 10 V Standards between the NSAI - NML (Ireland) and the BIPM, March to April 2011 (part of the ongoing BIPM key comparison BIPM.EM-K11.b)
    Power, O.
    Solve, S.
    Chayramy, R.
    Stock, M.
    [J]. METROLOGIA, 2011, 48
  • [29] Bilateral Comparison of 10 V Standards between the NSAI - NML (Ireland) and the BIPM, January to February 2013 (part of the ongoing BIPM key comparison BIPM.EM-K11.b)
    Power, O.
    Chayramy, R.
    Solve, S.
    Stock, M.
    [J]. METROLOGIA, 2014, 51
  • [30] Bilateral comparison of 1.018 V and 10 V standards between the KRISS (Republic of Korea) and the BIPM, February 2008 (part of the ongoing BIPM key comparison BIPM.EM-K11.a and b)
    Solve, S.
    Chayramy, R.
    Stock, M.
    Kim, K-T
    Song, W.
    Kim, M-S
    Chong, Y.
    [J]. METROLOGIA, 2008, 45