Use of a mixture of gadolinium and iodinated contrast for angiography

被引:5
|
作者
Badiola, CM [1 ]
机构
[1] Bristol Hosp, Dept Diagnost Imaging, Bristol, CT 06011 USA
关键词
gadolinium; iodinated contrast; contrast nephropathy;
D O I
10.1007/s00270-003-2643-8
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The purpose of this study was to determine if the image quality of gadolinium digital subtraction angiography (DSA) can be improved by the addition of small quantities of iodinated contrast to gadolinium. The optical density (01)) of a mixture of four parts gadolinium-based contrast to one part iodinated contrast was measured through a phantom study and compared to that of full-strength gadolinium, full strength iodinated contrast, and a 20% solution of iodinated contrast. We also compared the clinical image quality of the mixture of gadolinium-based contrast and iodinated contrast relative to full-strength gadolinium and full strength iodinated contrast during DSA. The DSA image quality of the gadolinium-iodinated contrast mixture was significantly improved relative to images obtained with full-strength gadolinium and compared favorably to that obtained with full-strength iodinated contrast. The phantom data showed that the OD of the gadolinium-iodinated contrast mixture was much greater than that of full strength gadolinium and the 20% iodinated contrast solution. The increase in OD was greater than that expected from a simple additive effect of the OD of the contrast agents. Adding a small amount of iodinated contrast to gadolinium results in a significant improvement in the radiographic density and DSA image quality of gadolinium. This simple technique appears to overcome one of the major limitations of gadolinium-based angiography-poor radiographic density-while continuing to minimize the volume of administered iodinated contrast.
引用
收藏
页码:148 / 150
页数:3
相关论文
共 50 条
  • [31] Gadodiamide as an alternative contrast medium in cerebral angiography in a patient with sensitivity to iodinated contrast medium
    A. Arat
    H. S. Cekirge
    I. Saatci
    [J]. Neuroradiology, 2000, 42 : 34 - 37
  • [32] Use of gadolinium-based contrast agent for renal angiography: Case report and review of the literature
    Bassilios, N
    Vantelon, C
    Cluzel, P
    Baumelou, A
    Deray, G
    [J]. RENAL FAILURE, 2001, 23 (06) : 857 - 861
  • [33] Gadolinium contrast media for DSA in azotemia:: Are they really safer than iodinated agents?
    Nyman, U
    Elmståhl, B
    Leander, P
    Nilson, M
    Golman, K
    Almén, T
    [J]. ACADEMIC RADIOLOGY, 2002, 9 : S528 - S530
  • [34] Absence of Iodinated Contrast Hypersensitivity and Characterization of Gadolinium Utilization in an Interventional Pain Population
    Kalangara, Jerry
    Lanier, Kasey
    Beckworth, William J.
    Kuruvilla, Merin
    [J]. PAIN PRACTICE, 2021, 21 (02) : 184 - 189
  • [35] Iodinated Contrast Media in Pediatric Cardiac Angiography Nephrotoxic risk evaluation
    Cinteza, Eliza
    Balgradean, Mihaela
    Filip, Cristina
    Duica, Gabriela
    Nicolae, Georgiana
    Nicolescu, Alin
    Mahmoud, Hyam
    [J]. REVISTA DE CHIMIE, 2018, 69 (02): : 511 - 514
  • [36] Carbon Dioxide Angiography Is a Standard Technique to Supplement Iodinated Contrast Angiography and Can Be a Feasible Alternative
    Stegemann, Emilia
    Sansone, Roberto
    Heiss, Christian
    [J]. ANGIOLOGY, 2016, 67 (10) : 974 - 974
  • [37] Percutaneous carotid angioplasty and stenting with the use of gadolinium in lieu of iodinated contrast medium: Technical case report and review of the literature
    Amar, AP
    Larsen, DW
    Teitelbaum, GP
    [J]. NEUROSURGERY, 2001, 49 (05) : 1262 - 1265
  • [38] Gadolinium and carbon dioxide as an alternative to contrast medium in digital angiography
    Garcia-Monaco, R
    Bertoni, H
    Briggs, J
    Peralta, O
    Da Silva, J
    [J]. 21ST INTERNATIONAL CONGRESS OF RADIOLOGY, 2000, : 43 - 49
  • [39] Administration of Gadolinium-Based Contrast Agents in MR Angiography
    Lin, Kai
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 2009, 192 (04) : W193 - W193
  • [40] Safety of gadolinium contrast angiography in patients with chronic renal insufficiency
    Sam, AD
    Morasch, MD
    Collins, J
    Song, G
    Chen, R
    Pereles, FS
    [J]. JOURNAL OF VASCULAR SURGERY, 2003, 38 (02) : 313 - 318