Comparison of Immediate Implant Placement Following Extraction with and Without Socket-Shield Technique in Esthetic Region

被引:19
|
作者
Tiwari, Shamita [1 ]
Bedi, Ravinder Singh [1 ]
Wadhwani, Puneet [1 ]
Aurora, Jitender Kumar [1 ]
Chauhan, Himanshu [1 ]
机构
[1] Saraswati Dent Coll & Hosp, Dept OMFS, Lucknow, Uttar Pradesh, India
来源
关键词
Socket-shield technique; Immediate implants; Labial bone thickness; ANTERIOR MAXILLA; LABIAL BONE; WALL; RESORPTION; OUTCOMES;
D O I
10.1007/s12663-019-01272-3
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Introduction Immediate implant with socket shield and immediate implant without socket shield are the two techniques which can be used to preserve the already thin labial bone in the esthetic region, thus eliminating the need for graft materials. Aim To compare the efficacy of immediate implant placement after extraction without socket-shield technique and with socket-shield technique in the esthetic region. Materials and Methods Sixteen patients who reported with unsalvageable maxillary anterior teeth with labial bone thickness of less than 2 mm, depicted on preoperative CBCT, were chosen for the study and randomly assigned one of the two groups: Group A comprising socket-shield technique patients and Group B comprising immediate implant placement without socket shield. The labial bone thickness was analyzed along its entire length through CBCT scan at definite follow-up intervals up to a period of 12 months after the procedure. Results Follow-up of 1 year demonstrated a statistically significant reduction in the labial bone thickness at the crest in Group B after 8th and 12th months of implant placement. Conclusion The two techniques need further comparison though our study results demonstrated better preservation of bone through the socket-shield technique, thus eliminating the need for any bony substitutes.
引用
收藏
页码:552 / 560
页数:9
相关论文
共 50 条
  • [41] Immediate implant placement and loading in the esthetic area when the buccal socket wall is significantly damaged
    Tirone, Federico
    Genovesi, Francesco
    JOURNAL OF ESTHETIC AND RESTORATIVE DENTISTRY, 2021, 33 (04) : 542 - 549
  • [42] Comparison of Three-Dimensional Bone Changes in Socket Shield Technique Versus Immediate Implant Placement - A Non-Randomized Clinical Trial
    Chaudhary, Aditya
    Tushar
    Ranjan, Madhu
    Ananya
    Rani, Priya
    Prakash, Jayant
    JOURNAL OF PHARMACY AND BIOALLIED SCIENCES, 2024, 16 : S2788 - S2790
  • [43] FOR IMMEDIATE IMPLANT PLACEMENT, SOCKET SHIELD TECHNIQUE MAY SIGNIFICANTLY REDUCE MARGINAL BONE LOSS AS COMPARED TO CONVENTIONAL PROTOCOL
    Majid, Omer waleed
    JOURNAL OF EVIDENCE-BASED DENTAL PRACTICE, 2023, 23 (04)
  • [44] Fresh extraction socket: spontaneous healing vs. immediate implant placement
    Discepoli, Nicola
    Vignoletti, Fabio
    Laino, Luigi
    de Sanctis, Massimo
    Munoz, Fernando
    Sanz, Mariano
    CLINICAL ORAL IMPLANTS RESEARCH, 2015, 26 (11) : 1250 - 1255
  • [45] Comparative Evaluation of Immediate Implant Placement in Fresh Extraction Socket with and without the use of Platelet-Rich Fibrin
    Vivek
    Chaudhuri, Nabagata G.
    Patel, Shivam
    Mahajan, Aishwarya
    Luniyal, Shikha
    Srivastava, Sonal
    Makkad, Ramanpal S.
    JOURNAL OF PHARMACY AND BIOALLIED SCIENCES, 2024, 16 : S2315 - S2317
  • [46] Immediate Implant Placement into Fresh Extraction Socket in the Mandibular Molar Sites: A Preliminary Study of a Modified Insertion Technique
    Hamouda, Nelly I.
    Mourad, Samah I.
    El-Kenawy, Mohamed H.
    Maria, Ola M.
    CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2015, 17 : E107 - E116
  • [47] Alterations of the bone dimension following immediate implant placement into extraction socket: systematic review and meta-analysis
    Lee, Chun-Teh
    Chiu, Tzu-Shan
    Chuang, Sung-Kiang
    Tarnow, Dennis
    Stoupel, Janet
    JOURNAL OF CLINICAL PERIODONTOLOGY, 2014, 41 (09) : 914 - 926
  • [48] Influence of Socket-shield technique on the biomechanical response of dental implant: three-dimensional finite element analysis
    Mendes Tribst, Joao Paulo
    de Oliveira Dal Piva, Amanda Maria
    Souto Borges, Alexandre Luiz
    Bottino, Marco Antonio
    COMPUTER METHODS IN BIOMECHANICS AND BIOMEDICAL ENGINEERING, 2020, 23 (06) : 224 - 231
  • [49] Comparing the modified socket-shield technique with the conventional immediate implantation technique in the anterior dentition: A 5-year retrospective clinical study
    Li, Xingfu
    Li, Xinhan
    Xu, Yamei
    Fu, Gang
    Huang, Hong
    CLINICAL ORAL IMPLANTS RESEARCH, 2024, 35 (07) : 747 - 756
  • [50] Immediate implant placement utilizing vestibular socket therapy versus early implant placement with contour augmentation for rehabilitation of compromised extraction sockets in the esthetic zone: A randomized controlled clinical trial
    ElAskary, Abdelsalam
    Elfana, Ahmed
    Meabed, Moatez
    Radi, Iman Abd-ElWahab
    Akram, Mahmoud
    El-Sayed, Karim Fawzy
    CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2022, 24 (05) : 559 - 568