Outlier Issues in Harmonic Source Location Based on Parameter Identification Method

被引:0
|
作者
Tang, Kexuan [1 ]
Shen, Chen [1 ]
Liang, Shuo [2 ]
Huang, Xiuqiong [2 ]
机构
[1] Tsinghua Univ, Dept Elect Engn, State Key Lab Power Syst, Beijing, Peoples R China
[2] Guangxi Power Grid Corp, Nanning, Peoples R China
基金
中国国家自然科学基金;
关键词
Harmonic source location; non-linearity factor; outlier; parameter identification; power quality; CUSTOMER;
D O I
暂无
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
In this paper, the outlier issues in harmonic source location using parameter identification method are introduced and discussed. The theoretical models and outlier issues in parameter identification method are firstly introduced. Zerocrossing criteria of denominators in parameter solving processes are then obtained through theoretical derivations. Finally, the applicability of equivalent impedance models is discussed on the basis of theoretical and simulation results.
引用
收藏
页数:5
相关论文
共 50 条
  • [31] A Parameter-Free Outlier Detection Algorithm Based on Dataset Optimization Method
    Wang, Liying
    Shi, Lei
    Xu, Liancheng
    Liu, Peiyu
    Zhang, Lindong
    Dong, Yanru
    INFORMATION, 2020, 11 (01)
  • [32] A new ensemble method for outlier identification
    Alexandropoulos, Stamatios-Aggelos N.
    Kotsiantis, Sotiris B.
    Piperigou, Violetta E.
    Vrahatis, Michael N.
    PROCEEDINGS OF THE CONFLUENCE 2020: 10TH INTERNATIONAL CONFERENCE ON CLOUD COMPUTING, DATA SCIENCE & ENGINEERING, 2020, : 769 - 774
  • [33] Harmonic Source Localization Based on the Joint Entropy Method
    Lin, Qian
    Li, Mingming
    Feng, Shuhui
    Yang, Jingjing
    Sun, Xiaopeng
    Li, Jiangtao
    Wang, Zhiyuan
    Xie, Xiangmin
    2022 IEEE/IAS INDUSTRIAL AND COMMERCIAL POWER SYSTEM ASIA (I&CPS ASIA 2022), 2022, : 282 - 286
  • [34] Identification algorithm of harmonic source and flicker source
    Qi, Yong
    Jiang, Yaqun
    Huang, Chun
    Wu, Lepeng
    Dianli Zidonghua Shebei/Electric Power Automation Equipment, 2011, 31 (11): : 60 - 63
  • [35] A novel method for optimal capacitor placement and sizing based on harmonic source identification in distorted distribution systems
    Taher, S.A.
    Hosseini, S.A.
    Australian Journal of Electrical and Electronics Engineering, 2009, 6 (02): : 133 - 140
  • [36] Harmonic analysis method based on multi-harmonic source in power system
    Xia, Xiangyang
    Li, Lingli
    Yu, Hong
    Deng, Tanyu
    Luo, Jiping
    Huang, Hai
    Wang, Huan
    Xiang, Min
    Liu, Qifan
    Zhongnan Daxue Xuebao (Ziran Kexue Ban)/Journal of Central South University (Science and Technology), 2014, 45 (12): : 4239 - 4244
  • [37] Source location method based on corrected trilinear coordinates
    Wan, Qun
    Liu, Sheng-Jian
    Peng, Ying-Ning
    Tien Tzu Hsueh Pao/Acta Electronica Sinica, 2002, 30 (06): : 843 - 845
  • [38] Harmonic Source Location at the Point of Common Coupling Based on the Nonlinearity Index of Load
    Liu Yamei
    Gong Hualin
    Xiao Xianyong
    Yang Honggeng
    2009 ASIA-PACIFIC POWER AND ENERGY ENGINEERING CONFERENCE (APPEEC), VOLS 1-7, 2009, : 1300 - 1304
  • [39] Outlier Identification and Correction Online for the Ocean Geomagnetic Parameter Measurement
    Xu, Zunyi
    Wei, Dong
    Yan, Lei
    ADVANCES IN CIVIL ENGINEERING, PTS 1-4, 2011, 90-93 : 2822 - +
  • [40] A Dynamic Parameter Model of Harmonic Source Networks
    Ge, Xinliang
    Liu, Youwei
    IEEE TRANSACTIONS ON POWER DELIVERY, 2020, 35 (03) : 1093 - 1101