Comparison of plasma densities measured by using electrical probes to those measured by using microwave probes in inductively coupled plasmas

被引:0
|
作者
Kim, Won-Ki [1 ]
Lee, Min-Hyong
Chung, Chin-Wook
机构
[1] Hanyang Univ, Dept Elect Engn, Seoul 133791, South Korea
[2] Korea Res Inst Stand & Sci, Ctr Vacuum Technol, Taejon 305306, South Korea
关键词
plasma density; electrical probe; microwave probe;
D O I
暂无
中图分类号
O4 [物理学];
学科分类号
0702 ;
摘要
The plasma density in an argon inductively coupled plasma is measured at a point by using two electrical probes (a single Langmuir probe and a double Langmuir probe) and two microwave probes (a cut-off probe and a hairpin probe). In the case of the single Langmuir probe, to avoid the effect of RF fluctuations, we adapt an RF compensated probe and obtain the electron density or the plasma density from the electron energy distribution function (EEDF) measurement through a proper integral. In the case of the double probe, the plasma density is derived from the ion current. Of the microwave probes, the cut-off probe appears to be the most reliable because it works regardless of sheath formation. The plasma density obtained by using the double probe is found to be larger than those obtained by using the other probes, and the plasma densities obtained by using the cut-off probe and the single probe are in good agreement, within 5%, over a wide range. The plasma density obtained by using the hairpin probe is observed to be 30% larger than that obtained by using the cut-off probe. This discrepancy seems to be due to the effect of the sheath on the hairpin probe.
引用
收藏
页码:1687 / 1690
页数:4
相关论文
共 50 条
  • [11] A comparison of methane emissions from beef cattle measured using methane hoods with those measured using respiration chambers
    Troy, Shane M.
    Duthie, Carol-Anne
    Ross, Dave W.
    Hyslop, Jimmy J.
    Roehe, Rainer
    Waterhouse, Anthony
    Rooke, John A.
    ANIMAL FEED SCIENCE AND TECHNOLOGY, 2016, 211 : 227 - 240
  • [12] PLASMA SYNTHESIS OF POLYMERS - COMPARISON OF INDUCTIVELY COUPLED RF AND MICROWAVE PLASMAS EXCITED IN THE ISOMERIC DIFLUOROETHYLENES
    CLARK, DT
    SHUTTLEWORTH, D
    EUROPEAN POLYMER JOURNAL, 1979, 15 (03) : 265 - 269
  • [13] Electron density measurements in low-pressure plasmas using cutoff probes and comparison with hairpin and Langmuir probes
    Mishra, Himanshu
    Tuharin, Kostyantyn
    Turek, Zdenek
    Tichy, Milan
    Kudrna, Pavel
    PHYSICS OF PLASMAS, 2024, 31 (04)
  • [14] Highly efficient plasma generation in inductively coupled plasmas using a parallel capacitor
    Lim, Yeong-Min
    Hong, Young-Hun
    Kang, Gil-Ho
    Chung, Chin-Wook
    JOURNAL OF VACUUM SCIENCE & TECHNOLOGY A, 2023, 41 (01):
  • [15] Electrical characteristics of inductively coupled plasma using single langmuir probe
    Choi, YS
    Lee, YH
    Park, CS
    Hwang, MK
    Park, DH
    LIGHT SOURCES 2004, 2004, (182): : 255 - 256
  • [16] Multiplexed microRNA Detection Using Lanthanide-Labeled DNA Probes and Laser Ablation Inductively Coupled Plasma Mass Spectrometry
    de Bang, Thomas Christian
    Shah, Pratik
    Cho, Seok Keun
    Yang, Seong Wook
    Husted, Soren
    ANALYTICAL CHEMISTRY, 2014, 86 (14) : 6823 - 6826
  • [17] A comparison of femoral hip cortical widths and densities measured using pQCT and histomorphometry
    Mayhew, PM
    Loveridge, N
    Crabtree, N
    Power, J
    Reeve, J
    JOURNAL OF BONE AND MINERAL RESEARCH, 2002, 17 (05) : 957 - 957
  • [18] Design of CP system for newly constructed pipelines with respect to cathodic protection criteria based on DC and AC current densities measured using probes
    Hosokawa, Yuji
    Kajiyama, Fumio
    Fukaya, Tomoyuki
    Kikuchi, Jun
    Zairyo to Kankyo/ Corrosion Engineering, 2002, 51 (06): : 269 - 274
  • [19] Prospective Real-Time Head Motion Correction Using Inductively Coupled Wireless NMR Probes
    Sengupta, Saikat
    Tadanki, Sasidhar
    Gore, John C.
    Welch, E. Brian
    MAGNETIC RESONANCE IN MEDICINE, 2014, 72 (04) : 971 - 985
  • [20] Measurements of Plasma Properties Using Fast Sweep Langmuir Probes in Unmagnetized Weakly Ionized Plasmas
    Troll, O.
    Conde, L.
    Criado, E.
    Donoso, J. M.
    Herdrich, G.
    CONTRIBUTIONS TO PLASMA PHYSICS, 2010, 50 (09) : 819 - 823