Fully Automated Placental Volume Quantification From 3D Ultrasound for Prediction of Small-for-Gestational-Age Infants

被引:1
|
作者
Schwartz, Nadav [1 ]
Oguz, Ipek [2 ]
Wang, Jiancong [3 ]
Pouch, Alison [3 ]
Yushkevich, Natalie [3 ]
Parameshwaran, Shobhana [1 ]
Gee, James [3 ]
Yushkevich, Paul [3 ]
Oguz, Baris [3 ]
机构
[1] Univ Penn, Dept OBGYN, Maternal & Child Hlth Res Program, Philadelphia, PA 19104 USA
[2] Vanderbilt Univ, Dept EECS, Nashville, TN USA
[3] Univ Penn, Dept Radiol, Penn Image Comp & Sci Lab, Philadelphia, PA USA
关键词
D O I
10.1097/01.ogx.0000905268.90327.ea
中图分类号
R71 [妇产科学];
学科分类号
100211 ;
摘要
Preeclampsia, fetal growth restriction, and other adverse pregnancy outcomes are significant contributors to perinatal morbidity and mortality. Growing evidence links abnormalities in gross placental development to these outcomes. As such, placental morphometry has recently become a major focus of research. Ultrasound is inexpensive, broadly availability, and image acquisition is easy; therefore, it is the most common imaging modality used to study the placenta. However, 2D imaging has weak associations with adverse perinatal outcomes, whereas 3D ultrasound has allowed investigators insight into the relationship between clinical outcomes and first trimester placental volumes (PVs). However, the currently available techniques are laborious and require manual input. Automated segmentation methods would improve implementation in clinical practice. In this study, a state-of-the-art method for fully automated placenta segmentation and volume measurement is presented, with the overarching goal to create a multivariable prediction model capable of first-trimester identification of those with increased risk for developing fetal growth disorders. This secondary analysis of a prospective cohort of singleton gestations utilized volume data sets for the development of the fully automated segmentation pipeline. The ultrasound data volume sets were obtained at 11 to 14 weeks of gestation, using the max quality setting. The fully automated placenta segmentation pipeline required a ground truth set for the segmentation task and used 99 3D ultrasound manually segmented volume sets to train 3 convolutional neural networks (CNNs) through downsampling and upsampling structures. To evaluate reproducibility of this method, 25 unique subjects were identified for analysis using the CNN pipeline, then the resulting PV measurements were compared with those obtained using the more manual VOCAL tool reported in the primary analysis. Tests demonstrated that the fully automated CNN pipeline achieved a mean Dice similarity coefficient (a measurement of the performance of image segmentation analysis) of 0.8721 +/- 0.0591 on the n = 99 training set. Adjusted models including PV based on CNN (PVCNN) were predictive of SGA < 10%ile (area under the curve [AUC]: PV = 0.780). The addition of PVCNN to a clinical model yielded improvement in AUC (P < 0.05). For predicting SGA < 5%ile, including the PVCNN (0.897) improved performance of the clinical model (0.839, P = 0.015). At 11-14 weeks, PV measurements obtained using this tool were reproducible, significantly associated with the delivery of an SGA infant, and validated when compared with manual segmentation. Limitations of the study include the limited data set used to train during the CNN phase. However, additional evaluation using an independent n = 25 set yielded similar results to the 4-fold cross-validation produced from the n = 99 training set. In addition, all data set images in the study were obtained from a single team, using the same equipment, at one institution. Thus, performance drop is a possibility if this is applied to other equipment and teams. Creation and development of simplified and automated tools for the purposes of volume measurement (and automated placental segmentation) could potentially enable risk stratification earlier in pregnancy, and potentially allow the inclusion of placental biometry in clinical risk assessment. Further advancement of such tools also enables robust assessment of placental surface area and shape. Future development of microvascular Doppler could extend the use of automated placental segmentation tools to also map of the Doppler signal or aid the volumetric quantification. These advances all contribute to the achievable pregnancy clinical management goal of incorporating direct assessment of placental development.
引用
收藏
页码:713 / 715
页数:3
相关论文
共 50 条
  • [21] THE VALIDITY OF SCREENING FOR SMALL-FOR-GESTATIONAL-AGE AND LOW-WEIGHT-FOR-LENGTH INFANTS BY DOPPLER ULTRASOUND
    SIJMONS, EA
    REUWER, PJHM
    VANBEEK, E
    BRUINSE, HW
    BRITISH JOURNAL OF OBSTETRICS AND GYNAECOLOGY, 1989, 96 (05): : 557 - 561
  • [22] Routine ultrasound at 32 vs 36 weeks' gestation: prediction of small-for-gestational-age neonates
    Ciobanu, A.
    Khan, N.
    Syngelaki, A.
    Akolekar, R.
    Nicolaides, K. H.
    ULTRASOUND IN OBSTETRICS & GYNECOLOGY, 2019, 53 (06) : 761 - 768
  • [23] Prediction and prevention of small-for-gestational-age neonates: evidence from SPREE and ASPRE
    Tan, M. Y.
    Poon, L. C.
    Rolnik, D. L.
    Syngelaki, A.
    Matallana, C. De Paco
    Akolekar, R.
    Cicero, S.
    Janga, D.
    Singh, M.
    Molina, F. S.
    Persico, N.
    Jani, J. C.
    Plasencia, W.
    Greco, E.
    Papaioannou, G.
    Wright, D.
    Nicolaides, K. H.
    ULTRASOUND IN OBSTETRICS & GYNECOLOGY, 2018, 52 (01) : 52 - 59
  • [24] Fully automated, real-time 3D ultrasound segmentation to estimate first trimester placental volume using deep learning
    Looney, Padraig
    Stevenson, Gordon N.
    Nicolaides, Kypros H.
    Plasencia, Walter
    Molloholli, Malid
    Natsis, Stavros
    Collins, Sally L.
    JCI INSIGHT, 2018, 3 (11)
  • [25] Postnatal genetic and neurodevelopmental assessment in non-placental severely small-for-gestational-age infants born at term
    Borrell, A.
    Paz y Mino, F.
    Pauta, M.
    Meler, E.
    Mazarico, E.
    Matas Barcelo, I.
    Camacho, A.
    Segura, M.
    Figueras, F.
    ULTRASOUND IN OBSTETRICS & GYNECOLOGY, 2023, 62 : 58 - 58
  • [26] Doppler ultrasound of the uterine arteries: The importance of bilateral notching in the prediction of pre-eclampsia, placental abruption or delivery of a small-for-gestational-age baby
    Harrington, K
    Cooper, D
    Lees, C
    Hecher, K
    Campbell, S
    ULTRASOUND IN OBSTETRICS & GYNECOLOGY, 1996, 7 (03) : 182 - 188
  • [27] CIRCULATING BLOOD-VOLUME IN APPROPRIATE AND SMALL-FOR-GESTATIONAL-AGE FULL TERM AND PRETERM POLYCYTHEMIC INFANTS
    MAERTZDORF, WJ
    ALDENHUYZENDORLAND, W
    SLAAF, DW
    TANGELDER, GJ
    BLANCO, CE
    ACTA PAEDIATRICA SCANDINAVICA, 1991, 80 (6-7): : 620 - 627
  • [28] PLACENTAL PROTEIN-12 (PP12) - A NEW TEST FOR THE PREDICTION OF THE SMALL-FOR-GESTATIONAL-AGE INFANT
    HOWELL, RJS
    PERRY, LA
    CHOGLAY, NS
    BOHN, H
    CHARD, T
    BRITISH JOURNAL OF OBSTETRICS AND GYNAECOLOGY, 1985, 92 (11): : 1141 - 1144
  • [29] Effectiveness of third trimester ultrasound screening in the prediction of small-for-gestational-age neonates: a retrospective cohort study
    Collee, J.
    Noel, L.
    Henry, L.
    Nisolle, M.
    Chantraine, F.
    ULTRASOUND IN OBSTETRICS & GYNECOLOGY, 2023, 62 : 173 - 174
  • [30] GROWTH IN FULL-TERM SMALL-FOR-GESTATIONAL-AGE INFANTS - FROM BIRTH TO FINAL HEIGHT
    KARLBERG, J
    ALBERTSSONWIKLAND, K
    PEDIATRIC RESEARCH, 1995, 38 (05) : 733 - 739