Materials issues affecting vrla battery life

被引:0
|
作者
Moseley, PT [1 ]
机构
[1] Int Lead Zinc Res Org, Adv Lead Acid Battery Consortium, Res Triangle Pk, NC 27709 USA
关键词
D O I
暂无
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Towards the end of the twentieth century the lead-acid battery underwent a significant functional revision. For most of its long history the battery had operated with its plates immersed in a mobile electrolyte and provision had been made for gas produced during overcharge to be freely released into the atmosphere. The gases allowed to escape in this way represented a loss of water from the electrolyte which needed to be replaced in a regular maintenance operation. The modem, valve-regulated, lead-acid battery has been designed to operate an internal gas cycle in which oxygen evolved during overcharge of the positive electrode transfers through a gas space to the negative electrode where it is reduced. The oxygen cycle depolarizes the negative electrode and reduces hydrogen evolution to very low levels. A pressure release valve is provided to ensure that even the residual low level of hydrogen produced does not generate high pressure. The changes made to the construction of the battery in the move to the valve regulated design have brought new challenges for the materials scientist seeking to overcome the traditional life-limiting mechanisms of the lead-acid battery: paste softening, electrolyte stratification, incomplete charging and grid corrosion. The reward for a complete resolution of these issues is a battery that requires virtually no maintenance, presents no acid spill threat, and can be deployed with a minimal footprint.
引用
收藏
页码:385 / 398
页数:14
相关论文
共 50 条
  • [41] Complexity in battery systems: Thermal runaway in VRLA batteries
    Catherino, Henry A.
    JOURNAL OF POWER SOURCES, 2006, 158 (02) : 977 - 986
  • [42] Corrosion resistant positive grids, novel separators, and negative plate additives for increased VRLA battery life
    Prengaman, RD
    Siegmund, A
    SIXTEENTH ANNUAL BATTERY CONFERENCE ON APPLICATIONS AND ADVANCES, 2001, : 201 - 205
  • [43] Global VRLA battery standards for a global telecommunications industry
    Harrison, AI
    Kniveton, M
    INTELEC(R): TWENTY-SECOND INTERNATIONAL TELECOMMUNICATIONS ENERGY CONFERENCE, 2000, : 493 - 497
  • [44] VRLA battery rapid charging under stress management
    Hunter, PM
    Anbuky, AH
    IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2003, 50 (06) : 1229 - 1237
  • [45] An Analysis on the Performance of Network Complemtary VRLA Storage Battery
    Huang Junhui
    Du Ge
    TECHNOLOGY AND APPLICATION OF ELECTRONIC INFORMATION, 2009, : 27 - +
  • [46] Knowledge based VRLA battery monitoring and health assessment
    Anbuky, Adnan H.
    Pascoe, Phillip E.
    Hunter, Phillip M.
    INTELEC, International Telecommunications Energy Conference (Proceedings), 2000, : 687 - 694
  • [47] A fault diagnosis method for VRLA battery in data center
    Li, Xinhan
    Yang, Wen
    Pang, Aiping
    Jiang, Congmei
    Zhao, Qianchuan
    Haider, Syed Naeem
    ENERGY REPORTS, 2022, 8 : 14220 - 14235
  • [48] Catalyst enhanced, common headspace VRLA battery designs
    Misra, Sudhan S.
    Noveske, Terrence M.
    Williamson, Allan J.
    INTELEC, International Telecommunications Energy Conference (Proceedings), 2000, : 37 - 41
  • [49] Internal resistance and deterioration of VRLA battery - Analysis of internal resistance obtained by direct current measurement and its application to VRLA battery monitoring technique
    Kurisawa, I
    Iwata, M
    INTELEC 97 - 19TH INTERNATIONAL TELECOMMUNICATIONS ENERGY CONFERENCE, PROCEEDINGS: POWER AND ENERGY SYSTEMS IN CONVERGING MARKETS, 1997, : 687 - 694
  • [50] A VRLA battery energy storage system for Metlakatla, Alaska
    Miller, NW
    Zrebiec, RS
    Delmerico, RW
    Hunt, G
    Achenbach, HA
    ELEVENTH ANNUAL BATTERY CONFERENCE ON APPLICATIONS AND ADVANCES, 1996, : 241 - 248