Motion mitigation in scanned ion beam therapy through 4D-optimization

被引:72
|
作者
Graeff, Christian [1 ]
机构
[1] GSI Helmholzzentrum Schwerionenforsch GmbH, Darmstadt, Germany
来源
关键词
Treatment planning; 4D-optimization; Motion mitigation; Intrafractional motion; BREATHING-SYNCHRONIZED DELIVERY; MODULATED ARC THERAPY; PARTICLE THERAPY; RESPIRATORY MOTION; TRACKING SYSTEM; TUMOR MOTION; PROTON-BEAM; RADIOTHERAPY; OPTIMIZATION; MANAGEMENT;
D O I
10.1016/j.ejmp.2014.03.011
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The treatment of moving tumors remains challenging, especially with scanned ion beam therapy due to interplay effects and the strong range dependence. This is especially true in the context of radiosurgery with high dose delivered in few or single fractions. Inverse treatment planning on the entire 4D-CT may result in conformal plans inherently adapted to the moving anatomy of the patient. Existing studies on this topic for photon therapy are reviewed, but arguably the benefits for ion beam therapy can be even greater. Compared to the main conformal mitigation technique of beam tracking, 4D-optimization permits a) easier, offline handling of range changes, b) handling of complex motion patterns, and c) improved dose shaping capabilities outside of the target. Different approaches for 4D-optimization in scanned ion beam therapy are proposed and compared, together with delivery methods that provide the necessary synchronization between irradiation and detected patient motion. Potential solutions for the improvement of robustness in 4D-optimization are discussed. A method for delivery of homogenous doses to each motion phase is presented that might be a potential solution for robust conformal dose delivery for future clinical use. In an exemplary lung cancer patient case with a large motion amplitude, 4D-optimization resulted in conformal dose coverage while beam tracking did not. In conclusion, different strategies of 4D-optimization could provide increased OAR sparing and highly conformal dose delivery for targets with complex motion patterns and large amplitudes. (C) 2014 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:570 / 577
页数:8
相关论文
共 50 条
  • [21] Motion compensation with a scanned ion beam: a technical feasibility study
    Groezinger, Sven Oliver
    Bert, Christoph
    Haberer, Thomas
    Kraft, Gerhard
    Rietzel, Eike
    RADIATION ONCOLOGY, 2008, 3 (1)
  • [22] Motion compensation with a scanned ion beam: a technical feasibility study
    Sven Oliver Grözinger
    Christoph Bert
    Thomas Haberer
    Gerhard Kraft
    Eike Rietzel
    Radiation Oncology, 3
  • [23] Adjustment procedure for beam alignment in scanned ion-beam therapy
    Saraya, Y.
    Takeshita, E.
    Furukawa, T.
    Hara, Y.
    Mizushima, K.
    Saotome, N.
    Tansho, R.
    Shirai, T.
    Noda, K.
    JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2016, 69 (06) : 948 - 952
  • [24] Robustness of 4D-optimized scanned carbon ion beam therapy against interfractional changes in lung cancer
    Graeff, Christian
    RADIOTHERAPY AND ONCOLOGY, 2017, 122 (03) : 387 - 392
  • [25] Adjustment procedure for beam alignment in scanned ion-beam therapy
    Y. Saraya
    E. Takeshita
    T. Furukawa
    Y. Hara
    K. Mizushima
    N. Saotome
    R. Tansho
    T. Shirai
    K. Noda
    Journal of the Korean Physical Society, 2016, 69 : 948 - 952
  • [26] 4D offline PET-based treatment verification in scanned ion beam therapy: a phantom study
    Kurz, Christopher
    Bauer, Julia
    Unholtz, Daniel
    Richter, Daniel
    Stuetzer, Kristin
    Bert, Christoph
    Parodi, Katia
    PHYSICS IN MEDICINE AND BIOLOGY, 2015, 60 (16): : 6227 - 6246
  • [27] Dosimetric consequences of intrafraction prostate motion in scanned ion beam radiotherapy
    Ammazzalorso, Filippo
    Graef, Sebastian
    Weber, Uli
    Wittig, Andrea
    Engenhart-Cabillic, Rita
    Jelen, Urszula
    RADIOTHERAPY AND ONCOLOGY, 2014, 112 (01) : 100 - 105
  • [28] TREATMENT PLANNING FOR SCANNED ION BEAM THERAPY IN CLINICAL ROUTINE
    Ellerbrock, M.
    Ackermann, B.
    Brons, S.
    Heeg, P.
    Henkner, K.
    Ecker, S.
    Nairz, O.
    Winter, M.
    Mairani, A.
    Parodi, K.
    Jaekel, O.
    RADIOTHERAPY AND ONCOLOGY, 2010, 96 : S542 - S543
  • [29] Experimental Validation of a 4D Dose Calculation for Scanned Proton Beam Therapy
    Krieger, M.
    Klimpki, G.
    Fattori, G.
    Hrbacek, J.
    Oxley, D.
    Safai, S.
    Weber, D.
    Lomax, A.
    Zhang, Y.
    MEDICAL PHYSICS, 2017, 44 (06) : 3180 - 3180
  • [30] 4D in-beam positron emission tomography for verification of motion-compensated ion beam therapy
    Parodi, Katia
    Saito, Nami
    Chaudhri, Naved
    Richter, Christian
    Durante, Marco
    Enghardt, Wolfgang
    Rietzel, Eike
    Bert, Christoph
    MEDICAL PHYSICS, 2009, 36 (09) : 4230 - 4243