Experimental direct lightning current distribution in a reinforced concrete building

被引:1
|
作者
Sato, M [1 ]
Kuramoto, S
机构
[1] NTT, Serv Mkt & Support Headquarters, Tokyo 180, Japan
[2] NTT, Multimedia Networks Labs, Tokyo 180, Japan
关键词
lightning surge; direct lightning; lightning protection; grounding; building;
D O I
10.1002/(SICI)1520-6424(200004)83:4<53::AID-ECJA6>3.0.CO;2-U
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
When a building is hit by a direct lightning strike, the communication equipment may be damaged due to the current flowing on the columns, girders, and walls. Therefore, it is necessary to determine the current distribution and establish preventive procedures. Previously, the linear model in which the columns and girders are expressed in terms of lumped elements has been used for estimation of the current distributions in the buildings. However, few buildings have been studied. It is very important to understand correspondence between the models and the actual structures, such as the treatment of the buildings' walls and floors. The researchers in the past have experimentally investigated the equivalent impedance of the columns and girders with complex shapes and measured the currents on the actual columns and girders by designing a large-diameter Rogowski coil. Based on these results, a Lightning current application experiment was carried out using a steel-reinforced concrete building and a model scale without walls and floors. The effects of the ground, walls, and floors were studied and a comparison was carried out with the conventional computational method using the Linear model. The current distribution characteristics of the columns and girders were revealed. It was shown that, in the calculation of the current distributions, the ground resistivity needs to be considered in addition to the equivalent impedance of the columns and girders. Also, in the case where the exterior of the building is concrete walls, the current flowing through the steel reinforcement of the exterior walls is about 30% of the current flowing into the building. (C) 1999 Scripta Technica, Electron Comm Jpn Pt 1, 83(4): 53-62, 2000.
引用
收藏
页码:53 / 62
页数:10
相关论文
共 50 条
  • [21] Measurement of Magnetic Fields Generated by a Lightning Current Flowing Through Reinforced Concrete Walls
    Villamil, Susana Naranjo
    Gazave, Julien
    Piedallu, Eric
    Franchet, Maud
    Marquois, Boris
    Guiffaut, Christophe
    Reineix, Alain
    2022 36TH INTERNATIONAL CONFERENCE ON LIGHTNING PROTECTION (ICLP 2022), 2022, : 176 - 181
  • [22] FDTD Simulation of the Influence of Reinforced-Concrete on Lightning-Induced Surges in an Apartment Building
    Kawaguchi, Atsuya
    Baba, Yoshihiro
    Nagaoka, Naoto
    Saito, Mikihisa
    IEEJ TRANSACTIONS ON ELECTRICAL AND ELECTRONIC ENGINEERING, 2022, 17 (09) : 1294 - 1302
  • [23] The direct measurement of lightning current
    Flowers, JW
    JOURNAL OF THE FRANKLIN INSTITUTE, 1941, 232 : 425 - 450
  • [24] Analysis of Electromagnetic Fields Inside a Reinforced Concrete Building With Layered Reinforcing Bar due to Direct and Indirect Lightning Strikes Using the FDTD Method
    Tatematsu, Akiyoshi
    Rachidi, Farhad
    Rubinstein, Marcos
    IEEE TRANSACTIONS ON ELECTROMAGNETIC COMPATIBILITY, 2015, 57 (03) : 405 - 417
  • [25] Protection current distribution in reinforced concrete cathodic protection systems
    Hassanein, AM
    Glass, GK
    Buenfeld, NR
    CEMENT & CONCRETE COMPOSITES, 2002, 24 (01): : 159 - 167
  • [26] Protection against lightning of reinforced concrete buildings
    Bachelier, E.
    Issac, F.
    Prost, D.
    Miry, C.
    Amador, E.
    Duquerroy, P.
    2014 INTERNATIONAL CONFERENCE ON LIGHTNING PROTECTION (ICLP), 2014, : 735 - 740
  • [27] OVERVOLTAGES INDUCED IN STRUCTURAL CABLING NETWORK BY LIGHTNING CURRENT DISTRIBUTION IN LPS OF THE BUILDING
    Wiater, Jaroslaw
    Sowa, Andrzej
    Augustyniak, Leszek
    18TH INTERNATIONAL CONFERENCE ELECTROMAGNETIC DISTURBANCES EMD 2008, VOL 1, PROCEEDINGS, 2008, : 25 - 26
  • [28] Numerical Model of a Reinforced Concrete Building: Earthquake Analysis and Experimental Validation
    Nascimbene, Roberto
    PERIODICA POLYTECHNICA-CIVIL ENGINEERING, 2015, 59 (04): : 521 - 530
  • [29] The reinforced Concrete in the Storey Building
    Polnyi, Stefan
    BETON- UND STAHLBETONBAU, 2017, 112 (03) : 187 - 190
  • [30] Evaluation of Electric Fields inside the Steel Reinforced Concrete Building due to a Nearby Lightning Strike to Ground
    Hegde, Vishwanath
    Shivanand, Vinoda
    PROCEEDINGS OF THE 2019 IEEE REGION 10 CONFERENCE (TENCON 2019): TECHNOLOGY, KNOWLEDGE, AND SOCIETY, 2019, : 1509 - 1513