Automatic detection of anomalies in screening mammograms

被引:12
|
作者
Kendall, Edward J. [1 ]
Barnett, Michael G. [2 ]
Chytyk-Praznik, Krista [3 ]
机构
[1] Mem Univ Newfoundland, Janeway Child Hlth Ctr, Discipline Radiol, St John, NF A1B 3V6, Canada
[2] Prairie North Hlth Reg, Battlefords Off, North Battleford, SK S9A 1Z1, Canada
[3] Nova Scotia Canc Ctr, Dept Radiat Oncol, Halifax, NS B3H 1V7, Canada
来源
BMC MEDICAL IMAGING | 2013年 / 13卷
基金
加拿大自然科学与工程研究理事会;
关键词
COMPUTER-AIDED DETECTION; FALSE-POSITIVE REDUCTION; BREAST MASSES; DETECTION CAD; CLASSIFICATION; DIAGNOSIS; SEGMENTATION; CANADA; CANCER;
D O I
10.1186/1471-2342-13-43
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background: Diagnostic performance in breast screening programs may be influenced by the prior probability of disease. Since breast cancer incidence is roughly half a percent in the general population there is a large probability that the screening exam will be normal. That factor may contribute to false negatives. Screening programs typically exhibit about 83% sensitivity and 91% specificity. This investigation was undertaken to determine if a system could be developed to pre-sort screening-images into normal and suspicious bins based on their likelihood to contain disease. Wavelets were investigated as a method to parse the image data, potentially removing confounding information. The development of a classification system based on features extracted from wavelet transformed mammograms is reported. Methods: In the multi-step procedure images were processed using 2D discrete wavelet transforms to create a set of maps at different size scales. Next, statistical features were computed from each map, and a subset of these features was the input for a concerted-effort set of naive Bayesian classifiers. The classifier network was constructed to calculate the probability that the parent mammography image contained an abnormality. The abnormalities were not identified, nor were they regionalized. The algorithm was tested on two publicly available databases: the Digital Database for Screening Mammography (DDSM) and the Mammographic Images Analysis Society's database (MIAS). These databases contain radiologist-verified images and feature common abnormalities including: spiculations, masses, geometric deformations and fibroid tissues. Results: The classifier-network designs tested achieved sensitivities and specificities sufficient to be potentially useful in a clinical setting. This first series of tests identified networks with 100% sensitivity and up to 79% specificity for abnormalities. This performance significantly exceeds the mean sensitivity reported in literature for the unaided human expert. Conclusions: Classifiers based on wavelet-derived features proved to be highly sensitive to a range of pathologies, as a result Type II errors were nearly eliminated. Pre-sorting the images changed the prior probability in the sorted database from 37% to 74%.
引用
收藏
页数:11
相关论文
共 50 条
  • [41] Automatic Detection of Suspicious Lesions in Digital X-ray Mammograms
    Elmoufidi, Abdelali
    El Fahssi, Khalid
    Jai-Andaloussi, Said
    Sekkaki, Abderrahim
    Quellec, Gwenole
    Lamard, Mathieu
    Cazuguel, Guy
    ADVANCES IN UBIQUITOUS NETWORKING 2, 2017, 397 : 375 - 385
  • [42] A dual stage adaptive thresholding (DuSAT) for automatic mass detection in mammograms
    Anitha, J.
    Peter, J. Dinesh
    Pandian, S. Immanuel Alex
    COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE, 2017, 138 : 93 - 104
  • [43] An Automatic Mass Detection System in Mammograms Based on Complex Texture Features
    Tai, Shen-Chuan
    Chen, Zih-Siou
    Tsai, Wei-Ting
    IEEE JOURNAL OF BIOMEDICAL AND HEALTH INFORMATICS, 2014, 18 (02) : 618 - 627
  • [44] Automatic mass detection in mammograms using deep convolutional neural networks
    Agarwal, Richa
    Diaz, Oliver
    Llado, Xavier
    Yap, Moi Hoon
    Marti, Robert
    JOURNAL OF MEDICAL IMAGING, 2019, 6 (03)
  • [45] B-spline filtering for automatic detection of calcification lesions in mammograms
    Bueno, G.
    Sanchez, S.
    Ruiz, M.
    INFORMATION OPTICS, 2006, 860 : 410 - +
  • [46] Shape-based Automatic Detection of Pectoral Muscle Boundary in Mammograms
    Chen, Chunxiao
    Liu, Gao
    Wang, Jing
    Sudlow, Gail
    JOURNAL OF MEDICAL AND BIOLOGICAL ENGINEERING, 2015, 35 (03) : 315 - 322
  • [47] Automatic detection of microcalcification clusters after lossy compression of digitized mammograms
    Netsch, T
    Lang, M
    Tian, J
    Evertsz, CJ
    Peitgen, H
    Wells, RO
    RADIOLOGY, 1996, 201 : 697 - 697
  • [48] Automatic detection of the masses in the mammograms using characteristic modeling and neural networks
    Xu, Wei-Dong
    Liu, Wei
    Li, Li-Hua
    Xia, Shun-Ren
    Ma, Li
    Shao, Guo-Liang
    Zhang, Juan
    Dianzi Yu Xinxi Xuebao/Journal of Electronics and Information Technology, 2009, 31 (07): : 1653 - 1658
  • [49] An Efficient Biomedical Imaging Technique for Automatic Detection of Abnormalities in Digital Mammograms
    Jenifer, Sheeba
    Parasuraman, S.
    Kadirvel, Amudha
    JOURNAL OF MEDICAL IMAGING AND HEALTH INFORMATICS, 2014, 4 (02) : 291 - 296
  • [50] Shape-based Automatic Detection of Pectoral Muscle Boundary in Mammograms
    Chunxiao Chen
    Gao Liu
    Jing Wang
    Gail Sudlow
    Journal of Medical and Biological Engineering, 2015, 35 : 315 - 322