Variation in Pediatric Cervical Spine Computed Tomography Radiation Dose Index

被引:12
|
作者
Marin, Jennifer R. [1 ,2 ]
Sengupta, Debapriya [3 ]
Bhargavan-Chatfield, Mythreyi [3 ]
Kanal, Kalpana M. [4 ]
Mills, Angela M. [5 ]
Applegate, Kimberly E. [6 ]
机构
[1] Univ Pittsburgh, Sch Med, Dept Pediat, Pittsburgh, PA 15261 USA
[2] Univ Pittsburgh, Sch Med, Dept Emergency Med, Pittsburgh, PA 15261 USA
[3] Amer Coll Radiol, Reston, VA USA
[4] Univ Washington, Sch Med, Dept Radiol, Seattle, WA 98195 USA
[5] Univ Penn, Dept Emergency Med, Perelman Sch Med, Philadelphia, PA 19104 USA
[6] Emory Univ, Sch Med, Dept Radiol & Imaging Sci, Atlanta, GA 30322 USA
关键词
EMERGENCY-DEPARTMENT; CLEARANCE PROTOCOL; IMAGE QUALITY; CT; TRAUMA; VARIABILITY; EXPOSURE; CHILDREN; CHILDHOOD; INJURY;
D O I
10.1111/acem.12822
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Objectives: The objective was to evaluate variation in the current estimated radiation dose index for pediatric cervical spine (c-spine) computed tomography (CT) examinations. Methods: This was a retrospective analysis of pediatric (age younger than 19 years) c-spine CT examinations from the American College of Radiology Dose Index Registry, July 2011 through December 2014. We used the volume CT dose index (CTDIvol) as the radiation dose estimate and used summary statistics to describe patient and hospital characteristics. Results: There were 12,218 pediatric CT c-spine examinations performed across 296 participating hospitals. Fifty-six percent were in male patients, and 79% were in children older than 10 years. Most hospitals (55%) were community hospitals without trauma designations, and the largest proportion of examinations (41%) were performed at these hospitals. The median CTDIvol was 15 mGy (interquartile range = 9 to 23 mGy) representing a more than 2.5-fold difference between the 25th and 75th percentiles. Pediatric hospitals (both trauma and nontrauma centers) delivered the lowest CTDIvol across all age groups and showed the least amount of variability in dose. Conclusions: There is significant variation in the radiation dose index for pediatric c-spine CT examinations. Pediatric hospitals practice at lower CT dose estimates than other hospitals. Individual hospitals should examine their practices in an effort to ensure standardization and optimization of CT parameters to minimize radiation exposures to pediatric patients. (C) 2015 by the Society for Academic Emergency Medicine
引用
收藏
页码:1499 / 1505
页数:7
相关论文
共 50 条
  • [21] Factors Associated With the Use of Cervical Spine Computed Tomography Imaging in Pediatric Trauma Patients
    Mannix, Rebekah
    Nigrovic, Lise E.
    Schutzman, Sara A.
    Hennelly, Kara
    Bourgeois, Florence T.
    Meehan, William P.
    Fleisher, Gary
    Monuteaux, Michael
    Lee, Lois K.
    ACADEMIC EMERGENCY MEDICINE, 2011, 18 (09) : 906 - 911
  • [22] Radiation dose of chaperones during common pediatric computed tomography examinations
    Daniel Overhoff
    Meike Weis
    Philipp Riffel
    Sonja Sudarski
    Matthias F. Froelich
    Peter Fries
    Stefan Schönberg
    Joshua Gawlitza
    Pediatric Radiology, 2020, 50 : 1078 - 1082
  • [23] Estimation of normal computed tomography measurements for the upper cervical spine in the pediatric age group
    Vachhrajani, Shobhan
    Sen, Anish N.
    Satyan, Krishna
    Kulkarni, Abhaya V.
    Birchansky, Sherri B.
    Jea, Andrew
    JOURNAL OF NEUROSURGERY-PEDIATRICS, 2014, 14 (04) : 425 - 433
  • [24] PEDIATRIC DOSE REDUCTION IN COMPUTED TOMOGRAPHY
    Frush, Donald P.
    HEALTH PHYSICS, 2008, 95 (05): : 518 - 527
  • [25] Computed Tomography of the Spine Systematic Review on Acquisition and Reconstruction Techniques to Reduce Radiation Dose
    Dieckmeyer, Michael
    Sollmann, Nico
    Kupfer, Karina
    Loeffler, Maximilian T.
    Paprottka, Karolin J.
    Kirschke, Jan S.
    Baum, Thomas
    CLINICAL NEURORADIOLOGY, 2023, 33 (02) : 271 - 291
  • [26] Artifact Simulating Fracture on Cervical Spine Computed Tomography
    Shockley, Lee W.
    Kendall, John L.
    WESTERN JOURNAL OF EMERGENCY MEDICINE, 2011, 12 (02) : 240 - 241
  • [27] Image gently: Reducing radiation dose in pediatric computed tomography through collaboration
    Strauss, Keith J.
    Butler, Priscilla F.
    Goske, Marilyn J.
    Ritenour, E. Russell
    MEDICAL PHYSICS, 2009, 36 (12) : 5719 - 5720
  • [28] COMPUTED-TOMOGRAPHY OF THE RHEUMATOID CERVICAL-SPINE
    BRAUNSTEIN, E
    WEISSMAN, B
    SELTZER, S
    RUMBAUGH, C
    INVESTIGATIVE RADIOLOGY, 1983, 18 (04) : S32 - S32
  • [29] Radiation Dose from Computed Tomography Scans for Korean Pediatric and Adult Patients
    Won, Tristan
    Lee, Ae-Kyoung
    Choi, Hyung-do
    Lee, Choonsik
    JOURNAL OF RADIATION PROTECTION AND RESEARCH, 2021, 46 (03): : 98 - 105
  • [30] International variation in radiation dose for computed tomography examinations: prospective cohort study
    Smith-Bindman, Rebecca
    Wang, Yifei
    Chu, Philip
    Chung, Robert
    Einstein, Andrew J.
    Balcombe, Jonathan
    Cocker, Mary
    Das, Marcos
    Delman, Bradley N.
    Flynn, Michael
    Gould, Robert
    Lee, Ryan K.
    Yellen-Nelson, Thomas
    Schindera, Sebastian
    Seibert, Anthony
    Starkey, Jay
    Suntharalingam, Saravanabavaan
    Wetter, Axel
    Wildberger, Joachim E.
    Miglioretti, Diana L.
    BMJ-BRITISH MEDICAL JOURNAL, 2019, 364