Bioimpedance-Based Respiration Monitoring With a Defibrillator

被引:9
|
作者
Martinsen, Orjan G. [1 ,2 ]
Nordbotten, Bernt [1 ]
Grimnes, Sverre [1 ,2 ]
Fossan, Helge [3 ]
Eilevstjonn, Joar [3 ]
机构
[1] Univ Oslo, Dept Phys, N-0316 Oslo, Norway
[2] Oslo Univ Hosp, Dept Clin & Biomed Engn, N-0424 Oslo, Norway
[3] Laerdal Med, N-4002 Stavanger, Norway
关键词
Bioimpedance; defibrillator; respiration; sensitivity; ventilation;
D O I
10.1109/TBME.2014.2308924
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Defibrillators often use an ac measurement to ensure safe electrode placement. Some defibrillators also utilize impedance measurements for ventilation monitoring. This paper investigates how such measurements can be optimized for high respiration sensitivity and finds that it is beneficial to add two extra electrodes in addition to the two defibrillator electrodes. This four electrode setup increases sensitivity and also allows respiration measurements at lower frequencies than the two electrode setup.
引用
收藏
页码:1858 / 1862
页数:5
相关论文
共 50 条
  • [41] A Bioimpedance-Based Device to Assess the Volume Conduction Properties of the Tongue in Neurological Disorders Affecting Bulbar function
    Luo, Xuesong
    Pulido, Hilda V. Gutierrez
    Rutkove, Seward
    Sanchez, Benjamin
    IEEE OPEN JOURNAL OF ENGINEERING IN MEDICINE AND BIOLOGY, 2021, 2 : 278 - 285
  • [42] Bioimpedance-Based Wearable Measurement Instrumentation for Studying the Autonomic Nerve System Response to Stressful Working Conditions
    Ferreira, J.
    Alvarez, L.
    Buendia, R.
    Ayllon, D.
    Llerena, C.
    Gil-Pita, R.
    Seoane, F.
    XV INTERNATIONAL CONFERENCE ON ELECTRICAL BIO-IMPEDANCE (ICEBI) & XIV CONFERENCE ON ELECTRICAL IMPEDANCE TOMOGRAPHY (EIT), 2013, 434
  • [43] Real-Time Bioimpedance-Based Biopsy Needle Can Identify Tissue Type with High Spatial Accuracy
    Halonen, Sanna
    Kari, Juho
    Ahonen, Petri
    Kronstrom, Kai
    Hyttinen, Jari
    ANNALS OF BIOMEDICAL ENGINEERING, 2019, 47 (03) : 836 - 851
  • [44] A Novel Tissue Identification Framework in Cataract Surgery Using an Integrated Bioimpedance-Based Probe and Machine Learning Algorithms
    AghajaniPedram, Sahba
    Ferguson, Peter
    Gerber, Matthew
    Shin, Changyeob
    Hubschman, J-P
    Rosen, Jacob
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2022, 69 (02) : 910 - 920
  • [45] Bioimpedance-based respiratory gating method for oncologic positron emission tomography (PET) imaging with first clinical results
    Koivumaki, T.
    Vauhkonen, M.
    Teuho, J.
    Teras, M.
    Hakulinen, M. A.
    XV INTERNATIONAL CONFERENCE ON ELECTRICAL BIO-IMPEDANCE (ICEBI) & XIV CONFERENCE ON ELECTRICAL IMPEDANCE TOMOGRAPHY (EIT), 2013, 434
  • [46] Real-Time Bioimpedance-Based Biopsy Needle Can Identify Tissue Type with High Spatial Accuracy
    Sanna Halonen
    Juho Kari
    Petri Ahonen
    Kai Kronström
    Jari Hyttinen
    Annals of Biomedical Engineering, 2019, 47 : 836 - 851
  • [47] A non-invasive, bioimpedance-based 2-dimensional imaging system for detection and localization of pathological epithelial tissues
    Ching, Congo Tak-Shing
    Chen, Jhih-Hao
    SENSORS AND ACTUATORS B-CHEMICAL, 2015, 206 : 319 - 326
  • [48] Novel Electrode Placement in Electrical Bioimpedance-Based Stroke Detection: Effects on Current Penetration and Injury Characterization in a Finite Element Model
    Bronk, Theodore S.
    Everitt, Alicia C.
    Murphy, Ethan K.
    Halter, Ryan J.
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2022, 69 (05) : 1745 - 1757
  • [49] A Robust Electrode Configuration for Bioimpedance Measurement of Respiration
    Wang, Hong-bin
    Yen, Chen-wen
    Liang, Jing-tao
    Wang, Qian
    Liu, Guan-zheng
    Song, Rong
    JOURNAL OF HEALTHCARE ENGINEERING, 2014, 5 (03) : 313 - 327
  • [50] Wearable Bioimpedance-Based Deep Learning Techniques for Live Fish Health Assessment under Waterless and Low-Temperature Conditions
    Zhang, Yongjun
    Chen, Longxi
    Feng, Huanhuan
    Xiao, Xinqing
    Nikitina, Marina A.
    Zhang, Xiaoshuan
    SENSORS, 2023, 23 (19)