Bioimpedance-Based Respiration Monitoring With a Defibrillator

被引:9
|
作者
Martinsen, Orjan G. [1 ,2 ]
Nordbotten, Bernt [1 ]
Grimnes, Sverre [1 ,2 ]
Fossan, Helge [3 ]
Eilevstjonn, Joar [3 ]
机构
[1] Univ Oslo, Dept Phys, N-0316 Oslo, Norway
[2] Oslo Univ Hosp, Dept Clin & Biomed Engn, N-0424 Oslo, Norway
[3] Laerdal Med, N-4002 Stavanger, Norway
关键词
Bioimpedance; defibrillator; respiration; sensitivity; ventilation;
D O I
10.1109/TBME.2014.2308924
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Defibrillators often use an ac measurement to ensure safe electrode placement. Some defibrillators also utilize impedance measurements for ventilation monitoring. This paper investigates how such measurements can be optimized for high respiration sensitivity and finds that it is beneficial to add two extra electrodes in addition to the two defibrillator electrodes. This four electrode setup increases sensitivity and also allows respiration measurements at lower frequencies than the two electrode setup.
引用
收藏
页码:1858 / 1862
页数:5
相关论文
共 50 条
  • [1] Flexible bioimpedance-based dynamic monitoring of stress levels in live oysters
    Zhang, Luwei
    Li, You
    Du, Jiacheng
    Mu, Boyu
    Hu, Jinyou
    Zhang, Xiaoshuan
    AQUACULTURE, 2023, 577
  • [2] A Bioimpedance-Based Cardiovascular Measurement System
    Kusche, Roman
    Hauschild, Sebastian
    Ryschka, Martin
    WORLD CONGRESS ON MEDICAL PHYSICS AND BIOMEDICAL ENGINEERING 2018, VOL 2, 2019, 68 (02): : 839 - 842
  • [3] Electrical Bioimpedance-Based Monitoring of Intracochlear Tissue Changes After Cochlear Implantation
    Sijgers, Leanne
    Geys, Marlies
    Geissler, Gunnar
    Boyle, Patrick
    Huber, Alexander
    Pfiffner, Flurin
    Sensors, 2024, 24 (23)
  • [4] TARGET RANGES FOR BIOIMPEDANCE-BASED FLUID MANAGEMENT
    Moissl, Ulrich
    Chamney, Paul
    Wabel, Peter
    Elben, Marc
    Stuard, Stefano
    NEPHROLOGY DIALYSIS TRANSPLANTATION, 2015, 30
  • [5] PPG and Bioimpedance-Based Wearable Applications in Heart Rate Monitoring-A Comprehensive Review
    Lapsa, Didzis
    Janeliukstis, Rims
    Metshein, Margus
    Selavo, Leo
    APPLIED SCIENCES-BASEL, 2024, 14 (17):
  • [6] Bioimpedance-based identification of malnutrition using fuzzy logic
    Wieskotten, S.
    Heinke, S.
    Wabel, P.
    Moissl, U.
    Becker, J.
    Pirlich, M.
    Keymling, M.
    Isermann, R.
    PHYSIOLOGICAL MEASUREMENT, 2008, 29 (05) : 639 - 654
  • [8] Possibility of bioimpedance-based nutritional status assessment in rehabilitation
    Babett, Toth
    Dora, Terjek
    Rebeka, Nagy-Konya
    Zoltan, Denes
    ORVOSI HETILAP, 2022, 163 (17) : 670 - 676
  • [9] Development of a bioimpedance-based human machine interface for wheelchair control
    Huang Yunfei
    Phukpattaranont, Pornchai
    Wongkittisuksa, Booncharoen
    Tanthanuch, Sawit
    ECTI-CON: 2009 6TH INTERNATIONAL CONFERENCE ON ELECTRICAL ENGINEERING/ELECTRONICS, COMPUTER, TELECOMMUNICATIONS AND INFORMATION TECHNOLOGY, VOLS 1 AND 2, 2009, : 998 - 1001
  • [10] Bioimpedance-based Identification of Malnutrition Using Fuzzy-Logic
    Wieskotten, S.
    Heinke, S.
    Wabel, P.
    Moissl, U.
    Isermann, R.
    WORLD CONGRESS ON MEDICAL PHYSICS AND BIOMEDICAL ENGINEERING 2006, VOL 14, PTS 1-6, 2007, 14 : 1037 - +