Retrieval analysis of PEEK rods for posterior fusion and motion preservation

被引:34
|
作者
Kurtz, Steven M. [1 ,2 ]
Lanman, Todd H. [3 ]
Higgs, Genymphas [1 ]
MacDonald, Daniel W. [1 ]
Berven, Sigurd H. [4 ]
Isaza, Jorge E. [5 ]
Phillips, Eual [1 ]
Steinbeck, Marla J. [1 ]
机构
[1] Drexel Univ, Philadelphia, CA 19104 USA
[2] Exponent Inc, Menlo Pk, CA 94025 USA
[3] Univ Calif Los Angeles, Dept Surg, Los Angeles, CA 90024 USA
[4] Univ Calif San Francisco, Dept Orthopaed Surg, San Francisco, CA USA
[5] Tulane Univ, Baton Rouge, LA USA
关键词
PEEK rods; Posterior fusion; Retrieval analysis; Tissue response; Revision; SPINAL IMPLANTS; ADJACENT;
D O I
10.1007/s00586-013-2920-4
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
The purpose of this study was to analyze explanted PEEK rod spinal systems in the context of their clinical indications. We evaluated damage to the implant and histological changes in explanted periprosthetic tissues. 12 patients implanted with 23 PEEK rods were revised between 2008 and 2012. PEEK rods were of the same design (CD Horizon Legacy, Medtronic, Memphis TN, USA). Retrieved components were assessed for surface damage mechanisms, including plastic deformation, scratching, burnishing, and fracture. Patient history and indications for PEEK rod implantation were obtained from analysis of the medical records. 11/12 PEEK rod systems were employed for fusion at one level, and motion preservation at the adjacent level. Surgical complications in the PEEK cohort included a small dural tear in one case that was immediately repaired. There were no cases of PEEK rod fracture or pedicle screw fracture. Retrieved PEEK rods exhibited scratching, as well as impressions from the set screws and pedicle screw saddles. PEEK debris was observed in two patient tissues, which were located adjacent to PEEK rods with evidence of scratching and burnishing. This study documents the surface changes and tissue reactions for retrieved PEEK rod stabilization systems. Permanent indentations by the set screws and pedicle screws were the most prevalent observations on the surface of explanted PEEK rods.
引用
收藏
页码:2752 / 2759
页数:8
相关论文
共 50 条
  • [1] Retrieval analysis of PEEK rods for posterior fusion and motion preservation
    Steven M. Kurtz
    Todd H. Lanman
    Genymphas Higgs
    Daniel W. MacDonald
    Sigurd H. Berven
    Jorge E. Isaza
    Eual Phillips
    Marla J. Steinbeck
    European Spine Journal, 2013, 22 : 2752 - 2759
  • [2] A new concept of motion preservation surgery of the cervical spine: PEEK rods for the posterior cervical region
    Aydin, Ahmet Levent
    Sasani, Mehdi
    Erbulut, Deniz Ufuk
    Oktenoglu, Tunc
    Ozer, Ali Fahir
    BIO-MEDICAL MATERIALS AND ENGINEERING, 2020, 31 (04) : 235 - 251
  • [3] Polyetheretherketone (PEEK) rods versus titanium rods for posterior lumbar fusion surgery: a systematic review and meta-analysis
    Li, Wenhao
    Zhao, He
    Li, Chuanhong
    Liu, Tao
    Guan, Jianbin
    Yang, Yongdong
    Yu, Xing
    JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2023, 18 (01)
  • [4] Polyetheretherketone (PEEK) rods versus titanium rods for posterior lumbar fusion surgery: a systematic review and meta-analysis
    Wenhao Li
    He Zhao
    Chuanhong Li
    Tao Liu
    Jianbin Guan
    Yongdong Yang
    Xing Yu
    Journal of Orthopaedic Surgery and Research, 18
  • [5] Posterior lumbar fusion by peek rods in degenerative spine: preliminary report on 30 cases
    F. De Iure
    G. Bosco
    M. Cappuccio
    S. Paderni
    L. Amendola
    European Spine Journal, 2012, 21 : 50 - 54
  • [6] Posterior lumbar fusion by peek rods in degenerative spine: preliminary report on 30 cases
    De Iure, F.
    Bosco, G.
    Cappuccio, M.
    Paderni, S.
    Amendola, L.
    EUROPEAN SPINE JOURNAL, 2012, 21 : S50 - S54
  • [7] Retrieval analysis of PEEK rods pedicle screw system: three cases analysis
    Xu, Xiaoduo
    Wang, Lei
    Wang, Jingming
    Yu, Xiuchun
    Huang, Weimin
    BMC MUSCULOSKELETAL DISORDERS, 2024, 25 (01)
  • [8] Do PEEK Rods for Posterior Instrumented Fusion in the Lumbar Spine Reduce the Risk of Adjacent Segment Disease?
    Hirt, Daniel
    Prentice, Heather A.
    Harris, Jessica E.
    Paxton, Elizabeth W.
    Alexander, Jessa
    Nagasawa, Daniel T.
    Khosla, Deven
    Kurtz, Steven M.
    INTERNATIONAL JOURNAL OF SPINE SURGERY, 2021, 15 (02): : 251 - 258
  • [9] Polyetheretherketone (PEEK) Rods for Lumbar Fusion: A Systematic Review and Meta-Analysis
    Selim, Abdulhafez
    Mercer, Sarah
    Tang, Feng
    INTERNATIONAL JOURNAL OF SPINE SURGERY, 2018, 12 (02): : 190 - 200
  • [10] Comparative effectiveness of PEEK rods versus titanium alloy rods in lumbar fusion: A preliminary report
    Lei Qi
    Mu Li
    Shuai Zhang
    Jingsong Xue
    Haipeng Si
    Acta Neurochirurgica, 2013, 155 : 1187 - 1193