Evaluation and in situ assessment of photodegradation of polyaromatic hydrocarbons in semipermeable membrane devices deployed in ocean water

被引:14
|
作者
Komarova, Tatiana V. [1 ]
Bartkow, Michael E. [1 ]
Rutishauser, Sibylle [2 ]
Carter, Steve
Mueller, Jochen F. [1 ]
机构
[1] Univ Queensland, Natl Res Ctr Environm Toxicol EnTox, Coopers Plains, Qld, Australia
[2] Swiss Fed Inst Aquat Sci & Technol Eawag, Dept Environm Toxicol, CH-8600 Dubendorf, Switzerland
关键词
Performance reference compounds; Photodegradation; Semipermeable membrane devices; POLYCYCLIC AROMATIC-HYDROCARBONS; PASSIVE AIR SAMPLERS; SPMDS; CALIBRATION;
D O I
10.1016/j.envpol.2008.11.040
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Semipermeable membrane devices (SPMDs) were deployed in water using four different methods: a typical SPMD cage with and without a mesh cover, a bowl chamber and without any protection. In addition to routinely used performance reference compounds (PRCs), perdeuterated dibenz[a,h]anthracene was added. Due to its high sampler to water partition coefficient no measurable clearance due to diffusion was expected during the deployment period, hence any observed loss could be attributed to photodegradation. The loss of PRCs; was measured and SPMD-based water concentrations determined. Results showed that a typical SPMD deployment cage covered with mesh provided the best protection from photodegradation. Samplers which had undergone the highest photodegradation underestimated PAH water concentrations by up to a factor of 5 compared to the most protected SPMDs. This study demonstrates that the potential for photodegradation needs to be addressed when samplers are deployed in water of low turbidity. (C) 2008 Elsevier Ltd. All rights reserved.
引用
收藏
页码:731 / 736
页数:6
相关论文
共 50 条
  • [21] Determination of uptake kinetics (Sampling rates) by lipid-containing semipermeable membrane devices (SPMDs) for polycyclic aromatic hydrocarbons (PAHs) in water
    Huckins, JN
    Petty, JD
    Orazio, CE
    Lebo, JA
    Clark, RC
    Gibson, VL
    Gala, WR
    Echols, KR
    ENVIRONMENTAL SCIENCE & TECHNOLOGY, 1999, 33 (21) : 3918 - 3923
  • [22] Determination of uptake kinetics (sampling rates) by lipid-containing semipermeable membrane devices (SPMDs) for polycyclic aromatic hydrocarbons (PAHs) in water
    Columbia Environ. Research Center, U.S. Geological Survey, 4200 New Haven Road, Columbia, MO 65201, United States
    不详
    Environ. Sci. Technol., 21 (3918-3923):
  • [23] Simultaneous monitoring of profiles of polycyclic aromatic hydrocarbons in contaminated air with semipermeable membrane devices and spruce needles
    Zhu, Xiuhua
    Pfister, Gerd
    Henkelmann, Bernhard
    Kotalik, Jarmila
    Bernhoeft, Slike
    Fiedler, Stefan
    Schramm, Karl-Werner
    ENVIRONMENTAL POLLUTION, 2008, 156 (02) : 461 - 466
  • [24] Assessment of bioavailable PAH, PCB and OCP concentrations in water, using semipermeable membrane devices (SPMDs), sediments and caged carp
    Verweij, F
    Booij, K
    Satumalay, K
    van der Molen, N
    van der Oost, R
    CHEMOSPHERE, 2004, 54 (11) : 1675 - 1689
  • [25] USE OF SEMIPERMEABLE-MEMBRANE DEVICES FOR INSITU MONITORING OF POLYCYCLIC AROMATIC-HYDROCARBONS IN AQUATIC ENVIRONMENTS
    LEBO, JA
    ZAJICEK, JL
    HUCKINS, JN
    PETTY, JD
    PETERMAN, PH
    CHEMOSPHERE, 1992, 25 (05) : 697 - 718
  • [26] Accumulation of polycyclic aromatic hydrocarbons in semipermeable membrane devices and caged mussels (Mytilus edulis L.) in relation to water column phase distribution
    Axelman, J
    Næs, K
    Näf, C
    Broman, D
    ENVIRONMENTAL TOXICOLOGY AND CHEMISTRY, 1999, 18 (11) : 2454 - 2461
  • [27] LIPID-CONTAINING SEMIPERMEABLE-MEMBRANE DEVICES FOR MONITORING ORGANIC CONTAMINANTS IN WATER
    HUCKINS, JN
    MANUWEERA, GK
    PETTY, JD
    MACKAY, D
    LEBO, JA
    ENVIRONMENTAL SCIENCE & TECHNOLOGY, 1993, 27 (12) : 2489 - 2496
  • [28] Use of ionic liquid-filled semipermeable membrane for extraction of polycyclic aromatic hydrocarbons in water
    Zhao, WY
    Han, M
    Dai, SG
    Zhong, X
    CHINESE CHEMICAL LETTERS, 2005, 16 (04) : 520 - 522
  • [29] Passive water sampling for polynuclear aromatic hydrocarbons using lipid-containing semipermeable membrane devices (SPMDs): Application to contaminant residence times
    Prest, HF
    Jacobson, LA
    Wilson, M
    CHEMOSPHERE, 1997, 35 (12) : 3047 - 3063