Comparison of Tono-Pen AVIA Intraocular Pressure Measurements Performed at Limbus With Central Corneal Tono-Pen AVIA Intraocular Pressure

被引:5
|
作者
Sharma, Reetika [1 ]
Majumdar, Saptorishi [1 ]
Sobti, Amit [1 ]
Arora, Tarun [1 ]
Agarwal, Tushar [1 ]
Dada, Tanuj [1 ]
机构
[1] All India Inst Med Sci, Dr Rajendra Prasad Ctr Ophthalm Sci, Glaucoma Facil, New Delhi 110029, India
关键词
Tono-Pen AVIA; limbus; correlation; central cornea; GOLDMANN APPLANATION TONOMETER; CLINICAL-EVALUATION; CONTACT-LENSES; THICKNESS; EYES;
D O I
10.1097/ICO.0b013e31827c9d25
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To compare Tono-Pen AVIA (TPA) intraocular pressure (IOP) measurements performed at the limbus with central corneal Tono-Pen AVIA (TPA) intraocular pressure. Methods: Fifty-one patients attending our outpatient department with a best corrected visual acuity of >= 20/40, no corneal disease, and no astigmatism greater than 1.5 diopters underwent routine ophthalmological examination. Patients with ametropia greater than or equal to +/- 5 diopters, a history of recent contact lens wear, and central corneal thickness of <480 mu m or >550 mu m were excluded from the study. IOP was recorded first in the corneal center, followed by tonometry measurements obtained from the temporal, nasal, superior, and inferior limbus using TPA. IOP measurements were compared using the paired t test. Correlation was derived by Pearson correlation coefficient, and regression equations were derived. Results: The mean age of patients in our study was 43.86 +/- 15.39 years. The mean TPA IOP from the central cornea was 16.59 +/- 3.75 mm Hg. There was a statistically significant difference between Tono-Pen IOP from the central cornea and that recorded from all 4 limbal positions (P < 0.001). There was a positive correlation between the central and the limbal IOP obtained with Tono-Pen. Correlation was maximum for the temporal limbus. Conclusions: Limbal TPA IOP is significantly higher than central TPA IOP. There remains a good correlation between central and limbal IOP. This was found to be greatest for the temporal limbus.
引用
收藏
页码:943 / 946
页数:4
相关论文
共 50 条
  • [1] Evaluation of the applanation tonometer Tono-Pen Avia® Vet™ for the measurement of the canine and feline intraocular pressure
    Helbig, Stefanie
    Eule, J. Corinna
    TIERAERZTLICHE PRAXIS AUSGABE KLEINTIERE HEIMTIERE, 2021, 49 (02): : 86 - 92
  • [2] Intraocular Pressure Measurements in Standing, Sitting, and Supine Position: Comparison between Tono-Pen Avia and Icare Pro Tonometers
    De Bernardo, Maddalena
    Abbinante, Giulia
    Borrelli, Maria
    Di Stasi, Margherita
    Cione, Ferdinando
    Rosa, Nicola
    JOURNAL OF CLINICAL MEDICINE, 2022, 11 (21)
  • [3] Measurement of mouse intraocular pressure with the Tono-Pen
    Pang, IH
    Wang, WH
    Millar, JC
    Clark, AF
    EXPERIMENTAL EYE RESEARCH, 2005, 81 (03) : 359 - 360
  • [4] Intraocular Pressure in Primary Congenital Glaucoma (PCG): Draeger Applanation Tonometer versus Tono-pen Avia®
    Cronemberger, Sebastiao
    Veloso, Artur Abreu
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2020, 61 (07)
  • [5] Repeatability of intraocular pressure measurements with Icare PRO rebound, Tono-Pen AVIA, and Goldmann tonometers in sitting and reclining positions
    Schweier, Caterina
    Hanson, James V. M.
    Funk, Jens
    Toeteberg-Harms, Marc
    BMC OPHTHALMOLOGY, 2013, 13
  • [6] Positive correlation between Tono-Pen intraocular pressure and central corneal thickness
    Dohadwala, AA
    Munger, R
    Damji, KF
    OPHTHALMOLOGY, 1998, 105 (10) : 1849 - 1854
  • [7] Repeatability of intraocular pressure measurements with Icare PRO rebound, Tono-Pen AVIA, and Goldmann tonometers in sitting and reclining positions
    Caterina Schweier
    James VM Hanson
    Jens Funk
    Marc Töteberg-Harms
    BMC Ophthalmology, 13
  • [8] MEASUREMENT OF RABBIT INTRAOCULAR-PRESSURE WITH THE TONO-PEN
    MERMOUD, A
    BAERVELDT, G
    MINCKLER, DS
    LEE, MB
    RAO, NA
    OPHTHALMOLOGICA, 1995, 209 (05) : 275 - 277
  • [9] Twenty-four hours intraocular pressure in keratoconic eyes assessed by applanation tonometry and Tono-Pen AVIA
    Rafael Vidal Merola
    Sebasti?o Cronemberger
    Artur William Veloso
    Alberto Diniz-Filho
    International Journal of Ophthalmology, 2022, (01) : 52 - 58
  • [10] Comparison of Scleral Tono-Pen Intraocular Pressure Measurements with Goldmann Applanation Tonometry
    Badakere, Swathi Vallabh
    Choudhari, Nikhil S.
    Rao, Harsha L.
    Chary, C. Raghava
    Garudadri, Chandra Sekhar
    Senthil, Sirisha
    OPTOMETRY AND VISION SCIENCE, 2018, 95 (02) : 129 - 135