Objective: To investigate the effectiveness of a hands-free environmental control system.(ECS) that allows profoundly disabled persons to activate and control electric devices in their home by using consciously controlled changes in their brain signals. Design: A cohort study with a field trial testing of the ECS on 3 occasions. Setting: Participants' homes. Participants: Ten profoundly disabled persons (mean age, 42.9y), all of whom had very limited movement from the neck downward. Six had spinal cord injury with lesions ranging from C2 to C5-6. The other 4 had profound disability (1 each from polio, spinal muscular atrophy, multiple sclerosis, cerebral palsy). Interventions: Participants performed tasks on each of 3 test occasions. The tasks consisted of turning a television on at the beginning of the trial, changing channels (up, down), changing volume, and turning it off at the conclusion of each trial. Main Outcome Measures: Time participants took to select the correct option and number of errors made in selecting the correct option. Measures were taken for each trial, so that any improvement in switching could be detected. Results: All participants effectively used the ECS to operate their television sets. Selecting a correct option took about 30 seconds (with the majority of this time attributed to machine cycling time), with an error rate of 1.8 per 5 options selected. The time taken to operate the ECS reduced slightly over the 3 trials and selection errors reduced by around 50% (to less than 1 error per 5 options). Conclusions: With minimal training, profoundly disabled persons were able to use an ECS that uses changes in brain wave signals. This result demonstrates the efficacy of an additional and novel ECS in an area in which few switches are available.
引用
收藏
页码:1455 / 1458
页数:4
相关论文
共 50 条
  • [41] AN INTERPHONE SYSTEM FOR HANDS-FREE OPERATION IN HIGH AMBIENT NOISE
    TORICK, EL
    ALLEN, RG
    IEEE TRANSACTIONS ON AUDIO AND ELECTROACOUSTICS, 1966, AU14 (04): : 168 - &
  • [42] Adaptive beamformer for hands-free communication system in noisy environments
    Dam, HQ
    Nordholm, S
    Dam, HH
    Low, SY
    2005 IEEE INTERNATIONAL SYMPOSIUM ON CIRCUITS AND SYSTEMS (ISCAS), VOLS 1-6, CONFERENCE PROCEEDINGS, 2005, : 856 - 859
  • [43] Adaptive beamformer for hands-free communication system in noisy environments
    Dam, H. Q., Circuits and Systems Society, IEEE CASS; Science Council of Japan; The Inst. of Electronics, Inf. and Communication Engineers, IEICE; The Institute of Electrical and Electronics Engineers, Inc., IEEE (Institute of Electrical and Electronics Engineers Inc.):
  • [44] Interface Design for an Inexpensive Hands-Free Collaborative Videoconferencing System
    Lehment, Nicolas H.
    Erhardt, Katharina
    Rigoll, Gerhard
    2012 IEEE INTERNATIONAL SYMPOSIUM ON MIXED AND AUGMENTED REALITY (ISMAR) - SCIENCE AND TECHNOLOGY, 2012, : 295 - 296
  • [45] The effects of a hands-free communication device system in a surgical suite
    Richardson, Joshua E.
    Shah-Hosseini, Sina
    Fiadjoe, John E.
    Ash, Joan S.
    Rehman, Mohamed A.
    JOURNAL OF THE AMERICAN MEDICAL INFORMATICS ASSOCIATION, 2011, 18 (01) : 70 - 72
  • [46] Hands-free wearable system for helping in assembly tasks in aerospace
    Borro-Yagueez, Diego
    Servan-Blanco, Javier
    Manuel Cordero-Valle, Juan
    Roberto Sanchez-Tapia, Jairo
    Mas-Morate, Fernando
    Matey-Munoz, Luis
    DYNA, 2011, 86 (03): : 328 - 335
  • [47] Hands-free sheet music [Resources-hands on]
    Gibbs, W., 1600, Institute of Electrical and Electronics Engineers Inc. (51):
  • [48] THE EVOLUTION OF A HANDS-ON TOWARDS A HANDS-FREE LABORATORY
    Winnock, F.
    CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2011, 49 : S178 - S178
  • [49] Hands-free system with low-delay subband acoustic echo control and noise reduction
    Steinert, Kai
    Schoenle, Martin
    Beaugeant, Christophe
    Fingscheidt, Tim
    2008 IEEE INTERNATIONAL CONFERENCE ON ACOUSTICS, SPEECH AND SIGNAL PROCESSING, VOLS 1-12, 2008, : 1521 - +
  • [50] "Hands-Free" Noninvasive Body Contouring Devices: Review of Effectiveness and Patient Satisfaction
    Chilukuri, Suneel
    Mueller, Gregory
    JOURNAL OF DRUGS IN DERMATOLOGY, 2016, 15 (11) : 1402 - 1406