Damage evaluation in reinforced concrete using damping measurements

被引:0
|
作者
De Visscher, J [1 ]
De Wilde, WP [1 ]
Ndambi, JM [1 ]
Vantomme, J [1 ]
Peeters, B [1 ]
De Roeck, G [1 ]
机构
[1] Free Univ Brussels, Mech Mat & Construct Dept, B-1050 Brussels, Belgium
关键词
D O I
暂无
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Damping measurements have been performed on a reinforced concrete beam, at increasing levels of damage. The aim was to investigate if these data, which were obtained in a nondestructive way, could he used as indicators for the crack damage of the concrete. The increase of friction associated with the initiation and propagation of cracks should indeed cause an increase of the modal damping ratios of the test structure. It was found that the measured damping values are very sensitive to the vibration amplitude, as a result of the nonlinear behaviour of reinforced concrete. Using an experimental technique that allows us to measure the damping ratios of specific eigenmodes as function of vibration amplitude revealed that the nonlinearity of the damping is more sensitive to crack damage than the damping itself.
引用
收藏
页码:309 / 316
页数:8
相关论文
共 50 条
  • [21] Damping of reinforced concrete materials and members
    Leng, Qiao-Juan
    He, Yi-Bin
    Qian, Jiang
    Hunan Daxue Xuebao/Journal of Hunan University Natural Sciences, 2009, 36 (03): : 6 - 10
  • [22] Evaluation of machine learning in recognizing images of reinforced concrete damage
    Ching-Lung Fan
    Multimedia Tools and Applications, 2023, 82 : 30221 - 30246
  • [23] Evaluation of machine learning in recognizing images of reinforced concrete damage
    Fan, Ching-Lung
    MULTIMEDIA TOOLS AND APPLICATIONS, 2023, 82 (19) : 30221 - 30246
  • [24] Seismic damage evaluation of reinforced concrete buildings with slit walls
    Baetu, Sergiu Andrei
    Barbat, Alex H.
    Ciongradi, Ioan Petru
    Baetu, Georgeta
    ENGINEERING COMPUTATIONS, 2015, 32 (06) : 1661 - 1690
  • [25] Post-Earthquake Damage Evaluation of Reinforced Concrete Buildings
    Maeda, Masaki
    Kang, Dae Eon
    JOURNAL OF ADVANCED CONCRETE TECHNOLOGY, 2009, 7 (03) : 327 - 335
  • [26] Evaluation of fatigue damage in reinforced concrete slabs by acoustic emission
    Yuyama, S.
    Li, Z.-W.
    Yoshizawa, M.
    Tomokiyo, T.
    Uomoto, T.
    Insight: Non-Destructive Testing and Condition Monitoring, 2000, 42 (07): : 439 - 443
  • [27] Evaluation of fatigue damage in reinforced concrete slab by acoustic emission
    Yuyama, S
    Li, ZW
    Yoskizawa, M
    Tomokiyo, T
    Uomoto, T
    NDT & E INTERNATIONAL, 2001, 34 (06) : 381 - 387
  • [28] Evaluation of fatigue damage in reinforced concrete slab by acoustic emission
    Yuyama, S
    Li, ZW
    Yoshizawa, M
    Tomokiyo, T
    Uomoto, T
    NON-DESTRUCTIVE TESTING IN CIVIL ENGINEERING 2000: SEIKEN SYMPOSIUM NO. 26, 2000, : 283 - 292
  • [29] Nondestructive evaluation on damage of carbon fiber sheet reinforced concrete
    Lee, JK
    Lee, JH
    COMPOSITE STRUCTURES, 2002, 58 (01) : 139 - 147
  • [30] Evaluation of steel corrosion-induced concrete damage using electrical resistivity measurements
    Robles, Kevin Paolo V.
    Gucunski, Nenad
    Kee, Seong-Hoon
    CONSTRUCTION AND BUILDING MATERIALS, 2024, 411