Conceptual comparison of two computer models of corpuscle sectioning and of two algorithms for correction of ploidy measurements in tissue sections

被引:0
|
作者
Freed, JA [1 ]
机构
[1] Good Samaritan Hosp, Dept Pathol, Puyallup, WA 98371 USA
来源
关键词
computer models; algorithms; ploidies; image analysis; computer-assisted; image cytometry; computed corpuscle sectioning;
D O I
暂无
中图分类号
Q2 [细胞生物学];
学科分类号
071009 ; 090102 ;
摘要
OBJECTIVE: To compare two computer models of corpuscle sectioning and two algorithms for correction of ploidy measurements in tissue sections. STUDY DESIGN: Two models of corpuscle sectioning (the computed corpuscle sectioning program [CCSP] [Analyt Quant Cytol Histol 1997;19:376-386] and the ellipsoid sectioning program [ESP]) were run on a personal computer to generate synthetic corpuscle section data that model the sectioned nuclei in a tissue section. These synthetic data were analyzed by two algorithms for correction of ploidy measurements in tissue sections: the reference curve method (ACM) (Analyt Quant Cytol Histol 1997;19:376-386) and the method of McCready and Papadimitriou (MMP)(Analyt Quant Cytol 1983;5:117-123) for a variety of choices of section thickness and of nuclear section profile selection criteria. RESULTS: Previous recommendations (Analyt Quant Cytol Histol 1999;21:103-112) for optimization of ploidy analysis in tissue sections (selection of only center-containing sections of nuclei in ultrathin sections with a selection bias in favor of elliptical nuclear section profiles) are valid regardless of which corpuscle sectioning model and correction algorithm are employed. Perimeter correction may be desirable or necessary in some cases. The RCM has very significant advantages over the MMP, and the CCSP is more applicable to actual Ploidy analysis than is the ESP. CONCLUSION: The RCM always should be used to correct ploidy measurements in tissue sections. The MMP should not be used as the sole method but, when used, should be used with and interpreted in the context of the RCM.
引用
收藏
页码:17 / 25
页数:9
相关论文
共 50 条
  • [41] Middle-ear two-port measurements in human cadaveric temporal bones: Comparison with models
    Puria, S
    PROCEEDINGS OF THE 3RD SYMPOSIUM ON MIDDLE EAR MECHANICS IN RESEARCH AND OTOLOGY, 2004, : 43 - 50
  • [42] Comparison of Two Bare-Soil Reflectivity Models and Validation With L-Band Radiometer Measurements
    Schwank, Mike
    Voelksch, Ingo
    Wigneron, Jean-Pierre
    Kerr, Yann H.
    Mialon, Arnaud
    de Rosnay, Patricia
    Maetzler, Christian
    IEEE TRANSACTIONS ON GEOSCIENCE AND REMOTE SENSING, 2010, 48 (01): : 325 - 337
  • [43] Two algorithms of determining the middle point of the shoot apex by surrounding organ primordia positions and their usage for computer measurements of divergence angles
    Matkowski, A
    Karwowski, R
    Zagorska-Marek, B
    ACTA SOCIETATIS BOTANICORUM POLONIAE, 1998, 67 (02) : 151 - 159
  • [44] Comparison of two PV array models for the simulation of PV systems using five different algorithms for the parameters identification
    Kichou, Sofiane
    Silvestre, Santiago
    Guglielminotti, Letizia
    Mora-Lopez, Llanos
    Munoz-Ceron, Emilio
    RENEWABLE ENERGY, 2016, 99 : 270 - 279
  • [45] Comparison of two state-of-the-art rotating dipole sound source imaging technologies: Models, algorithms and applications
    Yu, Liang
    Jing, Qiulan
    Wang, Ran
    Ji, Rujie
    Jiang, Weikang
    APPLIED ACOUSTICS, 2023, 211
  • [46] A comparison of alternative specifications of the college attendance equation with an extension to two-stage selectivity-correction models
    Hilmer, MJ
    ECONOMICS OF EDUCATION REVIEW, 2001, 20 (03) : 263 - 278
  • [47] Comparison of two different secondary flow correction models for depth-averaged flow simulation of meandering channels
    Qin, Cuicui
    Shao, Xuejun
    Zhou, Gang
    12TH INTERNATIONAL CONFERENCE ON HYDROINFORMATICS (HIC 2016) - SMART WATER FOR THE FUTURE, 2016, 154 : 412 - 419
  • [48] Comparison of meibomian gland loss area measurements between two computer programs and intra–inter-observer agreement
    Manuel Garza-Leon
    Alejandra Gonzalez-Dibildox
    Nallely Ramos-Betancourt
    Everardo Hernandez-Quintela
    International Ophthalmology, 2020, 40 : 1261 - 1267
  • [49] Comparison of meibomian gland loss area measurements between two computer programs and intra-inter-observer agreement
    Garza-Leon, Manuel
    Gonzalez-Dibildox, Alejandra
    Ramos-Betancourt, Nallely
    Hernandez-Quintela, Everardo
    INTERNATIONAL OPHTHALMOLOGY, 2020, 40 (05) : 1261 - 1267
  • [50] Correction to: Comparison of corneal measurements in keratoconus eyes with two swept‑source‑optical coherence tomography devices and a Scheimpflug device
    Alexandra Bograd
    Isabelle Himmel
    Isabel B. Pfister
    Theo G. Seiler
    Beatrice E. Frueh
    Christoph Tappeiner
    Graefe's Archive for Clinical and Experimental Ophthalmology, 2024, 262 : 1009 - 1009