Conceptual comparison of two computer models of corpuscle sectioning and of two algorithms for correction of ploidy measurements in tissue sections

被引:0
|
作者
Freed, JA [1 ]
机构
[1] Good Samaritan Hosp, Dept Pathol, Puyallup, WA 98371 USA
来源
关键词
computer models; algorithms; ploidies; image analysis; computer-assisted; image cytometry; computed corpuscle sectioning;
D O I
暂无
中图分类号
Q2 [细胞生物学];
学科分类号
071009 ; 090102 ;
摘要
OBJECTIVE: To compare two computer models of corpuscle sectioning and two algorithms for correction of ploidy measurements in tissue sections. STUDY DESIGN: Two models of corpuscle sectioning (the computed corpuscle sectioning program [CCSP] [Analyt Quant Cytol Histol 1997;19:376-386] and the ellipsoid sectioning program [ESP]) were run on a personal computer to generate synthetic corpuscle section data that model the sectioned nuclei in a tissue section. These synthetic data were analyzed by two algorithms for correction of ploidy measurements in tissue sections: the reference curve method (ACM) (Analyt Quant Cytol Histol 1997;19:376-386) and the method of McCready and Papadimitriou (MMP)(Analyt Quant Cytol 1983;5:117-123) for a variety of choices of section thickness and of nuclear section profile selection criteria. RESULTS: Previous recommendations (Analyt Quant Cytol Histol 1999;21:103-112) for optimization of ploidy analysis in tissue sections (selection of only center-containing sections of nuclei in ultrathin sections with a selection bias in favor of elliptical nuclear section profiles) are valid regardless of which corpuscle sectioning model and correction algorithm are employed. Perimeter correction may be desirable or necessary in some cases. The RCM has very significant advantages over the MMP, and the CCSP is more applicable to actual Ploidy analysis than is the ESP. CONCLUSION: The RCM always should be used to correct ploidy measurements in tissue sections. The MMP should not be used as the sole method but, when used, should be used with and interpreted in the context of the RCM.
引用
收藏
页码:17 / 25
页数:9
相关论文
共 50 条
  • [1] Possibility of correcting image cytometric nuclear DNA (ploidy) measurements in tissue sections - Insights from computed corpuscle sectioning and the reference curve method
    Freed, JA
    ANALYTICAL AND QUANTITATIVE CYTOLOGY AND HISTOLOGY, 1997, 19 (05): : 376 - 386
  • [2] Improved correction of quantitative nuclear DNA (ploidy) measurements in tissue sections
    Freed, JA
    ANALYTICAL AND QUANTITATIVE CYTOLOGY AND HISTOLOGY, 1999, 21 (02): : 103 - 112
  • [3] Comparison of Two Computer Algorithms To Identify Surgical Site Infections
    Apte, Mandar
    Landers, Timothy
    Furuya, Yoko
    Hyman, Sandra
    Larson, Elaine
    SURGICAL INFECTIONS, 2011, 12 (06) : 459 - 464
  • [4] Comparison of two laryngeal tissue fiber constitutive models
    Eric J. Hunter
    Anil Kumar Reddy Palaparthi
    Thomas Siegmund
    Roger W. Chan
    Mechanics of Time-Dependent Materials, 2014, 18 : 179 - 196
  • [5] A COMPARISON OF TWO METHODS FOR IN SITU HYBRIDIZATION USING PARRAFIN TISSUE SECTIONS
    Marcino, Joe
    Dungan, Chris
    JOURNAL OF SHELLFISH RESEARCH, 2012, 31 (01): : 317 - 318
  • [6] Comparison of two laryngeal tissue fiber constitutive models
    Hunter, Eric J.
    Palaparthi, Anil Kumar Reddy
    Siegmund, Thomas
    Chan, Roger W.
    MECHANICS OF TIME-DEPENDENT MATERIALS, 2014, 18 (01) : 179 - 196
  • [7] Moco -: Comparison of two different algorithms for motion correction in breast MRI
    Schwarz-Boeger, U.
    Mueller, M.
    Schimpfle, G.
    Harbeck, N.
    Zahlmann, G.
    Schmidt, M.
    Geppert, C.
    Heywang-Koebrunner, S.
    ONKOLOGIE, 2008, 31 : 141 - 141
  • [8] Comparison of two models for spin polarization measurements by Andreev reflection
    Ji, Y
    Strijkers, GJ
    Yang, RY
    Chien, CL
    PHYSICAL REVIEW B, 2001, 64 (22):
  • [9] Comparison of two microwave radiobrightness models and validation with field measurements
    Crosson, WL
    Laymon, CA
    Inguva, R
    Bowman, C
    IEEE TRANSACTIONS ON GEOSCIENCE AND REMOTE SENSING, 2002, 40 (01): : 143 - 152
  • [10] Comparison of two methods for SPECT attenuation correction without transmission measurements
    Gourion, D
    Hatchondo, X
    Gantet, P
    Noll, D
    Esquerré, JP
    2001 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORDS, VOLS 1-4, 2002, : 2183 - 2187