Automation of the ELISpot assay for high-throughput detection of antigen-specific T-cell responses

被引:15
|
作者
Almeida, Coral-Ann M. [1 ,2 ]
Roberts, Steven G. [1 ,2 ]
Laird, Rebecca [1 ,2 ]
McKinnon, Elizabeth [1 ,2 ]
Ahmed, Imran [1 ,2 ]
Pfafferott, Katja [1 ,2 ]
Turley, Joanne [1 ,2 ]
Keane, Niamh M. [1 ,2 ]
Lucas, Andrew [1 ,2 ]
Rushton, Ben [1 ,2 ]
Chopra, Abha [1 ,2 ]
Mallal, Simon [1 ,2 ,3 ]
John, Mina [1 ,2 ,3 ]
机构
[1] Royal Perth Hosp, Ctr Clin Immunol & Biomed Stat, Perth, WA 6000, Australia
[2] Murdoch Univ, Perth, WA, Australia
[3] Royal Perth Hosp, Dept Clin Immunol & Immunogenet, Perth, WA 6000, Australia
基金
英国医学研究理事会;
关键词
ELISpot; CD8(+) T-cells; IFN-gamma; Automation; High-throughput; HIV; CYTOKINE FLOW-CYTOMETRY; INFECTION; VIRUS; VALIDATION;
D O I
10.1016/j.jim.2009.02.007
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The enzyme linked immunospot (ELISpot) assay is a fundamental tool in cellular immunology, providing both quantitative and qualitative information on cellular cytokine responses to defined antigens. It enables the comprehensive screening of patient derived peripheral blood mononuclear cells to reveal the antigenic restriction of T-cell responses and is an emerging technique in clinical laboratory investigation of certain infectious diseases. As with all cellular-based assays, the final results of the assay are dependent on a number of technical variables that may impact precision if not highly standardised between operators. When studies that are large scale or using multiple antigens are set up manually, these assays may be labour intensive, have many manual handling steps, are subject to data and sample integrity failure and may show large inter-operator variability. Here we describe the successful automated performance of the interferon (IFN)-gamma ELISpot assay from cell counting through to electronic capture of cytokine quantitation and present the results of a comparison between automated and manual performance of the ELISpot assay. The mean number of spot forming units enumerated by both methods for limiting dilutions of CMV. EBV and influenza (CEF)-derived peptides in six healthy individuals were highly correlated (r>0.83, p<0.05). The precision results from the automated system compared favourably with the manual ELISpot and further ensured electronic tracking. increased through-put and reduced turnaround time. (C) 2009 Elsevier B.V. All rights reserved.
引用
收藏
页码:1 / 5
页数:5
相关论文
共 50 条
  • [21] ANTIGEN-SPECIFIC T-CELL RECEPTORS
    MARCHALONIS, JJ
    SCHLUTER, SF
    METHODS IN ENZYMOLOGY, 1987, 150 : 628 - 666
  • [22] In Vivo Assay for Detection of Antigen-specific T-cell Cytolytic Function Using a Vaccination Model
    Haymaker, Cara L.
    Hailemichael, Yared
    Yang, Yi
    Nurieva, Roza
    JOVE-JOURNAL OF VISUALIZED EXPERIMENTS, 2017, (129):
  • [23] Enumerating antigen-specific T-Cell responses in peripheral blood - A comparison of peptide MHC tetramer, ELISpot, and intracellular cytokine analysis
    Hobeika, AC
    Morse, MA
    Osada, T
    Ghanayem, M
    Niedzwiecki, D
    Barrier, R
    Lyerly, HK
    Clay, TM
    JOURNAL OF IMMUNOTHERAPY, 2005, 28 (01) : 63 - 72
  • [24] Mesoporous silica particles potentiate antigen-specific T-cell responses
    Kupferschmidt, Natalia
    Qazi, Khaleda Rahman
    Kemi, Cecilia
    Vallhov, Helen
    Garcia-Bennett, Alfonso E.
    Gabrielsson, Susanne
    Scheynius, Annika
    NANOMEDICINE, 2014, 9 (12) : 1835 - 1846
  • [25] Quantitation of antigen-specific CD8+ T-cell responses
    Ogg, GS
    McMichael, AJ
    IMMUNOLOGY LETTERS, 1999, 66 (1-3) : 77 - 80
  • [26] Evaluation of Antigen-Specific T-Cell Responses with a Miniaturized and Automated Method
    Pira, Giuseppina Li
    Ivaldi, Federico
    Dentone, Chiara
    Righi, Elda
    Del Bono, Valerio
    Viscoli, Claudio
    Koopman, Gerrit
    Manca, Fabrizio
    CLINICAL AND VACCINE IMMUNOLOGY, 2008, 15 (12) : 1811 - 1818
  • [27] ANTIGEN SELECTION PROMOTES CLONAL CYTOTOXIC T-CELL RESPONSES: HIGH-THROUGHPUT IMMUNOGENETIC EVIDENCE
    Stalika, E.
    Galigalidou, C.
    Papalexandri, A.
    Vardi, A.
    Stavroyianni, N.
    Batsis, I.
    Sakellari, I.
    Anagnostopoulos, A.
    Maglaveras, N.
    Chouvarda, I.
    Papaioannou, M.
    Stamatopoulos, K.
    Hadzidimitriou, A.
    HAEMATOLOGICA, 2017, 102 : 577 - 577
  • [28] Comparison of ELISPOT and cell surface cytokine capture assay as tests for antigen specific T-cell activation
    Janssen, W. E.
    Xu, M.
    Valins, W.
    CYTOTHERAPY, 2006, 8
  • [29] Association of Antigen-Specific T-cell Responses with Antigen Expression and Immunoparalysis in Multiple Myeloma
    Fichtner, Sabrina
    Hose, Dirk
    Engelhardt, Melanie
    Meissner, Tobias
    Neuber, Brigitte
    Krasniqi, Fatime
    Raab, Marc
    Schoenland, Stefan
    Ho, Anthony D.
    Goldschmidt, Hartmut
    Hundemer, Michael
    CLINICAL CANCER RESEARCH, 2015, 21 (07) : 1712 - 1721
  • [30] Novel IFNγ ELISPOT Assay for Detection of Functional Carcinoembryonic Antigen-Specific Chimeric Antigen Receptor-Redirected T Cells
    Elkord, E.
    Burt, D. J.
    SCANDINAVIAN JOURNAL OF IMMUNOLOGY, 2011, 74 (04) : 419 - 422