Prediction of the speech intelligibility index behind a single screen in an open-plan office

被引:14
|
作者
Wang, C [1 ]
Bradley, JS [1 ]
机构
[1] Natl Res Council Canada, Inst Res Construct, Ottawa, ON K1A 0R6, Canada
关键词
D O I
10.1016/S0003-682X(02)00003-8
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Improved acoustical privacy is the principal goal of the acoustical design of open plan offices. As the replacement of the Articulation Index (AI), the Speech Intelligibility Index (SII) can be used as a single-number measure of the speech privacy in open-plan offices. In this paper, a mathematical model of the speech propagation over single screens in a large open-plan office space is presented. The calculated effects of the office parameters, such as the screen height, ceiling and floor absorption, etc. on the SII behind the screen are discussed and are compared with measured results. To facilitate the practical use of the model, an empirical correction is derived from a wide range of ceiling tiles to provide values of the effective sound absorption of typical suspended ceilings in open offices. Compared to measured results, SII can be predicted with an RMS error of 0.03. Crown Copyright (C) 2002 Published by Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:867 / 883
页数:17
相关论文
共 50 条
  • [31] PRIVACY AND COMMUNICATION IN AN OPEN-PLAN OFFICE - A CASE-STUDY
    SUNDSTROM, E
    HERBERT, RK
    BROWN, DW
    ENVIRONMENT AND BEHAVIOR, 1982, 14 (03) : 379 - 392
  • [32] Employee Well-Being in Open-Plan Office Spaces
    Minutillo, Susannah
    Cleary, Michelle
    Visentin, Denis
    ISSUES IN MENTAL HEALTH NURSING, 2020, 42 (01) : 103 - 105
  • [33] Exploring soundscaping options for the cognitive environment in an open-plan office
    Lee, Young
    Nelson, Elizabeth
    Flynn, Mark J.
    Jackman, Joshua S.
    BUILDING ACOUSTICS, 2020, 27 (03) : 185 - 202
  • [34] Prediction of the Effectiveness of a Sound-Masking System in an Open-Plan Office Including the Lombard Effect
    Lei, Yizhong
    Hodgson, Murray
    ACTA ACUSTICA UNITED WITH ACUSTICA, 2013, 99 (05) : 729 - 736
  • [35] Staffs' physiological responses to irrelevant background speech and mental workload in open-plan bank office workspaces
    Golmohammadi, Rostam
    Motlagh, Masoud Shafiee
    Aliabadi, Mohsen
    Faradmal, Javad
    Ranjbar, Akram
    WORK-A JOURNAL OF PREVENTION ASSESSMENT & REHABILITATION, 2023, 76 (02): : 623 - 636
  • [36] Open-plan office noise levels, annoyance and countermeasures in Egypt
    Ali, Sayed Abas
    NOISE CONTROL ENGINEERING JOURNAL, 2011, 59 (02) : 186 - 193
  • [37] Energy efficient thermal comfort in open-plan office buildings
    Nagarathinam, Srinarayana
    Doddi, Harish
    Vasan, Arunchandar
    Sarangan, Venkatesh
    Ramakrishna, Venkata P.
    Sivasubramaniam, Anand
    ENERGY AND BUILDINGS, 2017, 139 : 476 - 486
  • [38] Open-plan office, employees' enactment, interpretations and reactions to territoriality
    Monaghan, Natalya
    Ayoko, Oluremi Bolanle
    INTERNATIONAL JOURNAL OF MANPOWER, 2019, 40 (02) : 228 - 245
  • [39] Evaluation of acoustic characteristics of Chinese open-plan office environment
    Jiao, Fenglei
    Kang, Jian
    Zhang, Mei
    Shengxue Xuebao/Acta Acustica, 2010, 35 (02): : 179 - 184
  • [40] A further study of a mathematical model for a screen in open-plan offices
    Han, Ning
    Mak, Cheuk Ming
    APPLIED ACOUSTICS, 2008, 69 (11) : 1114 - 1119