Development and validation of a gas chromatography-flame ionization detection method for quantifying sucrose in equine serum

被引:5
|
作者
Hewetson, Michael [1 ]
Aaltonen, Kaisa [1 ]
Tulamo, Riitta-Mari [1 ]
Sankari, Satu [1 ]
机构
[1] Univ Helsinki, Fac Vet Med, FIN-00014 Helsinki, Finland
关键词
Equine; gas chromatography-flame ionization detection; permeability; serum; sucrose; GASTRIC-ULCERATION; LIQUID-CHROMATOGRAPHY; TRIMETHYLSILYL DERIVATIVES; ENZYMATIC ASSAY; SUGAR ALCOHOLS; ORGANIC-ACIDS; BREATH TEST; PERMEABILITY; HORSES; PREVALENCE;
D O I
10.1177/1040638713519640
中图分类号
S85 [动物医学(兽医学)];
学科分类号
0906 ;
摘要
A simple and accurate method for quantifying sucrose in equine serum that can be applied to sucrose permeability testing in the horse was developed and validated using gas chromatography with flame ionization detection. The assay provided an acceptable degree of linearity, accuracy, and precision at concentrations of sucrose as low as 2.34 mol/l and as high as 20.45 mol/l. Percentage recovery of sucrose from serum ranged from 89% to 102%; repeatability and intermediate precision (relative standard deviation) ranged from 3.6% to 6.7% and 4.1% to 9.3%, respectively. The limit of detection was 0.73 mol/l. No interfering peaks were observed except lactose, which gave 2 peaks, one of which overlapped partially with sucrose. To evaluate the suitability of the method for quantifying sucrose in serum samples from horses with naturally occurring gastric ulceration, 10 horses with and without naturally occurring gastric ulceration were subjected to sucrose permeability testing. All horses demonstrated an increase in serum sucrose concentration over time following oral administration of sucrose; however, the increase from baseline was significant for horses with gastric ulceration at 45 min (P = 0.0082) and 90 min (P = 0.0082) when compared with healthy horses. It was concluded that gas chromatography with flame ionization detection is a valid method for quantifying sucrose in equine serum and can be applied directly to the analysis of sucrose in equine serum as part of a larger validation study aimed at developing a blood test for the diagnosis of gastric ulcers in horses.
引用
收藏
页码:232 / 239
页数:8
相关论文
共 50 条
  • [31] Determination of Fatty Acid Methyl Esters by Gas Chromatography-Flame Ionization Detection: Response Mechanism and Quantitative Pattern
    Cui H.
    Yang H.
    Sun L.
    Ye Q.
    Ding C.
    Wang W.
    Ji T.
    Ma L.
    Zeng K.
    Yin Q.
    Shipin Kexue/Food Science, 2024, 45 (13): : 49 - 57
  • [32] Analysis of amikacin, gentamicin and tobramycin by thin layer chromatography-flame ionization detection
    Anyakudo, Felix
    Adams, Erwin
    Schepdael, Ann Van
    MICROCHEMICAL JOURNAL, 2020, 157
  • [33] Application of static headspace gas chromatography-flame ionization detection in determination of chlorobenzenes and benzene series in aqueous environment
    Hu, Hongmei
    Zhang, Xiaoning
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2016, 251
  • [34] Development of headspace-gas chromatography-flame ionization detection procedure to determine volatile fatty acids in zoo organic waste leachates
    Banel, Anna
    Wasielewska, Marta
    Felchner-Zwirello, Monika
    Zygmunt, Bogdan
    WATER SCIENCE AND TECHNOLOGY, 2011, 63 (12) : 2873 - 2877
  • [35] Effect of sample matrix on the determination of total petroleum hydrocarbons (TPH) in soil by gas chromatography-flame ionization detection
    Saari, Eija
    Peraemaeki, Paavo
    Jalonen, Jorma
    MICROCHEMICAL JOURNAL, 2007, 87 (02) : 113 - 118
  • [36] Determination of fluoride in toothpaste using headspace solid-phase microextraction and gas chromatography-flame ionization detection
    Wejnerowska, Grazyna
    Karczmarek, Anna
    Gaca, Jerzy
    JOURNAL OF CHROMATOGRAPHY A, 2007, 1150 (1-2) : 173 - 177
  • [37] Determination of Total Petroleum Hydrocarbons in Australian Groundwater Through the Improvised Gas Chromatography-Flame Ionization Detection Technique
    Faustorilla, Maria Vilma
    Chen, Zuliang
    Dharmarajan, Rajarathnam
    Naidu, Ravendra
    JOURNAL OF CHROMATOGRAPHIC SCIENCE, 2017, 55 (08) : 775 - 783
  • [38] Pyrolysis-mass spectrometry and gas chromatography-flame ionization detection as complementary tools for soil lipid characterization
    Jeannotte, R.
    Hamel, C.
    Jabaji, S.
    Whalen, J. K.
    JOURNAL OF ANALYTICAL AND APPLIED PYROLYSIS, 2011, 90 (02) : 232 - 237
  • [39] Gas chromatography-flame ionization detector for sweat based COVID-19 screening
    Tungkijanansin, Nuttanee
    Phusrisom, Sorachar
    Chatdarong, Kaywalee
    Torvorapanit, Pattama
    Sirinara, Patthrarawalai
    Nhujak, Thumnoon
    Kulsing, Chadin
    ANALYTICA CHIMICA ACTA, 2023, 1280
  • [40] High performance mini-gas chromatography-flame ionization detector system based on micro gas chromatography column
    Zhu, Xiaofeng
    Sun, Jianhai
    Ning, Zhanwu
    Zhang, Yanni
    Liu, Jinhua
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2016, 87 (04):