Controlled clinical comparison of VersaTREK and BacT/ALERT blood culture systems

被引:20
|
作者
Mirrett, Stanley
Hanson, Kimberly E.
Reller, L. Barth
机构
[1] Duke Univ, Med Ctr, Clin Microbiol Lab, Durham, NC 27710 USA
[2] Duke Univ, Sch Med, Dept Pathol, Durham, NC 27710 USA
[3] Duke Univ, Sch Med, Dept Med, Durham, NC 27710 USA
关键词
D O I
10.1128/JCM.01697-06
中图分类号
Q93 [微生物学];
学科分类号
071005 ; 100705 ;
摘要
To assess the relative yields in automated microbial detection systems of bacteria and yeasts isolated from the blood of adult patients with suspected sepsis, we compared the new VersaTREK system (VTI) (TREK Diagnostic Systems, Cleveland, 011) to the BacT/ALERT 3D system (3D) (bioMerieux, Inc., Durham, NC). Identical protocols were followed for the two systems. Paired aerobic (REDOX 1) and anaerobic (REDOX 2) VTI media were compared with standard aerobic (SA) and anaerobic (SN) 3D media; each of the four culture bottles was filled with 6 to 9 ml of blood. All bottles flagged positive by the instruments were subcultured to determine both true-positive (growth) and false-positive (no growth) cultures. Additionally, to assess false-negative bottles, terminal subcultures were done on all negative companion bottles to true-positive bottles. All isolates were identified by standard methods. All 4 bottles were adequately filled and yielded 413 clinically significant isolates in 5,389 (79%) of the 6,786 4-bottle sets obtained. Although no overall difference in yield or in time to detection was detected between the two systems, significantly more streptococci and enterococci as a group were detected by VTI. Moreover, significantly more microorganisms were detected by VTI for patients receiving antimicrobial therapy. The two systems were comparable (P, not significant) at detecting the 179 unimicrobial episodes of bacteremia seen. False-positive rates for aerobic and anaerobic bottles, respectively, were 1.6% and 0.9% for VTI and 0.7% and 0.8% for 3D. We conclude that the VTI and 3D systems are comparable for detection of bloodstream infections with bacteria or yeasts.
引用
收藏
页码:299 / 302
页数:4
相关论文
共 50 条
  • [41] Direct comparison of the BACTEC 9240 and BacT/ALERT 3D automated blood culture systems for Candida growth detection
    Horvath, LL
    George, BJ
    Murray, CK
    Harrison, LS
    Hospenthal, DR
    JOURNAL OF CLINICAL MICROBIOLOGY, 2004, 42 (01) : 115 - 118
  • [42] Growth and maturation of Plasmodium falciparum in BacT Alert blood culture system
    McCarthy, KM
    Frean, J
    Loakes, J
    Liebowitz, LD
    TRANSACTIONS OF THE ROYAL SOCIETY OF TROPICAL MEDICINE AND HYGIENE, 1999, 93 (03) : 272 - 274
  • [43] Comparison of Growth Performance of the BacT/ALERT VIRTUO and BACTEC FX Blood Culture Systems Under Simulated Bloodstream Infection Conditions
    Park, Joonhong
    Han, Seounghwan
    Shin, Soyoung
    CLINICAL LABORATORY, 2017, 63 (01) : 39 - 46
  • [44] Controlled Clinical Comparison of Three Commercial Blood Culture Systems
    U. Frank
    D. Malkotsis
    D. Mlangeni
    F. D. Daschner
    European Journal of Clinical Microbiology and Infectious Diseases, 1999, 18 : 248 - 255
  • [45] Comparison of time-to-detection of Mindray TDR and BacT/ALERT®3D blood culture systems using simulated blood cultures
    Aydemir, Ozlem
    Ormanoglu, Gokcen
    Koroglu, Mehmet
    Aydemir, Yusuf
    ACTA CLINICA BELGICA, 2024, 79 (03) : 168 - 173
  • [46] Controlled clinical comparison of three commercial blood culture systems
    Frank, U
    Malkotsis, D
    Mlangeni, D
    Daschner, FD
    EUROPEAN JOURNAL OF CLINICAL MICROBIOLOGY & INFECTIOUS DISEASES, 1999, 18 (04) : 248 - 255
  • [47] Controlled clinical comparison of plastic and glass bottles of BacT/ALERT FA medium for culturing organisms from blood of adult patients
    Petti, CA
    Mirrett, S
    Woods, CW
    Reller, LB
    JOURNAL OF CLINICAL MICROBIOLOGY, 2005, 43 (04) : 1960 - 1962
  • [48] GROWTH AND DETECTION OF FILAMENTOUS FUNGI IN THE BACT/ALERT BLOOD CULTURE SYSTEM
    BREATHNACH, A
    EVANS, J
    JOURNAL OF CLINICAL PATHOLOGY, 1995, 48 (07) : 670 - 672
  • [49] Use of the BacT/Alert blood culture system for culture of sterile body fluids other than blood
    Bourbeau, P
    Riley, J
    Heiter, BJ
    Master, R
    Young, C
    Pierson, C
    JOURNAL OF CLINICAL MICROBIOLOGY, 1998, 36 (11) : 3273 - 3277
  • [50] In vitro Evaluation of BACT/ALERT® VIRTUO®, BACT/ALERT 3D®, and BACTEC™ FX Automated Blood Culture Systems for Detection of Microbial Pathogens Using Simulated Human Blood Samples
    Menchinelli, Giulia
    Liotti, Flora Marzia
    Fiori, Barbara
    De Angelis, Giulia
    D'Inzeo, Tiziana
    Giordano, Lilian
    Posteraro, Brunella
    Sabatucci, Michela
    Sanguinetti, Maurizio
    Spanu, Teresa
    FRONTIERS IN MICROBIOLOGY, 2019, 10