Development of an intraoperative gamma camera based on a 256-pixel mercuric iodide detector array

被引:15
|
作者
Patt, BE [1 ]
Tornai, MP [1 ]
Iwanczyk, JS [1 ]
Levin, CS [1 ]
Hoffman, EJ [1 ]
机构
[1] UNIV CALIF LOS ANGELES,SCH MED,DIV NUCL MED & BIOPHYS,DEPT MOL & MED PHARMACOL,LOS ANGELES,CA 90095
基金
美国国家卫生研究院;
关键词
D O I
10.1109/23.596995
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
A 256-element mercuric iodide (HgI2) detector array has been developed which is intended for use as an intraoperative gamma camera (IOGC). The camera is specifically designed for use in imaging gamma-emitting radiopharmaceuticals (such as 99m-Tc labeled Sestamibi) incorporated into brain tumors in the intraoperative surgical environment. The system is intended to improve the success of tumor removal surgeries by allowing more complete removal of subclinical tumor cells without removal of excessive normal tissue. The use of HgI2 detector arrays in this application facilitates construction of an imaging head that is very compact and has a high SNR. The detector is configured as a cross-grid array. Pixel dimensions are 1.25 mm squares separated by 0.25 mm. The overall dimension of the detector is 23.75 mm on a side. The detector thickness is 1 mm which corresponds to over 60% stopping at 140 keV. The array has good uniformity with average energy resolution of 5.2 +/- 2.9 % FWHM at 140 keV (best resolution was 1.9 % FWHM). Response uniformity (+/- sigma) was 7.9 %. A study utilizing realistic tumor phantoms (uptake ratio varied from 2:1 to 100:1) in background (1 mCi/l) was conducted. SNR's for the reasonably achievable uptake ratio of 50:1 were 5.61 sigma with 1 cm of background depth (''normal tissue'') and 2.74 sigma with 4 cm of background for a 6.3 mu l tumor phantom (similar to 270 nCi at the time of the measurement).
引用
收藏
页码:1242 / 1248
页数:7
相关论文
共 50 条
  • [21] A Silicon-Based Closed-Loop 256-Pixel Near-Field Capacitive Sensing Array with 3-ppm Sensitivity and Selectable Frequency Shift Gain
    Zhou, Jia
    Liang, Chia-Jen
    Chen, Christopher
    Du, Jieqiong
    Huang, Rulin
    Al Hadis, Richard
    Hwang, James C. M.
    Chang, Mau-Chung Frank
    PROCEEDINGS OF THE 2020 IEEE/MTT-S INTERNATIONAL MICROWAVE SYMPOSIUM (IMS), 2020, : 464 - 467
  • [22] THE DEVELOPMENT OF MERCURIC IODIDE GAMMA-RADIATION DETECTORS FOR APPLICATION IN NUCLEAR-MEDICINE
    LEVI, A
    ROTH, M
    SCHIEBER, M
    LAVY, S
    COOPER, G
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1982, 29 (01) : 457 - 460
  • [23] A novel 2-dimensional cosmic ray position detector based on a CsI(Na) pixel array and an ICCD camera
    葛永帅
    王志刚
    俞伯祥
    谢宇广
    章爱武
    薛镇
    刘颖彪
    高龙
    牛顺利
    蔡啸
    方建
    孙希磊
    吕绮雯
    宁飞鹏
    周莉
    胡涛
    吕军光
    Chinese Physics C, 2012, (11) : 1101 - 1105
  • [24] Development of Gamma Ray Imaging Systems using Mercuric Iodide (HgI2)
    van den Berg, L.
    Vigil, R. D.
    Bastian, L. F.
    Austin, R. A.
    2008 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (2008 NSS/MIC), VOLS 1-9, 2009, : 4984 - 4987
  • [25] A novel 2-dimensional cosmic ray position detector based on a CsI(Na) pixel array and an ICCD camera
    Ge Yong-Shuai
    Wang Zhi-Gang
    Yu Bo-Xiang
    Xie Yu-Guang
    Zhang Ai-Wu
    Xue Zhen
    Liu Ying-Biao
    Gao Long
    Niu Shun-Li
    Cai Xiao
    Fang Jian
    Sun Xi-Lei
    Lu Qi-Wen
    Ning Fei-Peng
    Zhou Li
    Hu Tao
    Lu Jun-Guang
    CHINESE PHYSICS C, 2012, 36 (11) : 1101 - 1105
  • [26] A novel 2-dimensional cosmic ray position detector based on a CsI(Na) pixel array and an ICCD camera
    葛永帅
    王志刚
    俞伯祥
    谢宇广
    章爱武
    薛镇
    刘颖彪
    高龙
    牛顺利
    蔡啸
    方建
    孙希磊
    吕绮雯
    宁飞鹏
    周莉
    胡涛
    吕军光
    Chinese Physics C, 2012, 36 (11) : 1101 - 1105
  • [27] Development of a mixed-mode pixel array detector for macromolecular crystallography
    Angello, SG
    Augustine, F
    Ercan, A
    Gruner, SM
    Hamlin, RC
    Hontz, T
    Xuong, NH
    Renzi, MJ
    Schuette, DR
    Tate, MW
    Vernon, W
    2004 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-7, 2004, : 4667 - 4671
  • [28] Fabrication of 721-pixel silicon lens array of a microwave kinetic inductance detector camera
    Mitsui, Kenji
    Nitta, Tom
    Okada, Norio
    Sekimoto, Yutaro
    Karatsu, Kenichi
    Sekiguchi, Shigeyuki
    Sekine, Masakazu
    Noguchi, Takashi
    JOURNAL OF ASTRONOMICAL TELESCOPES INSTRUMENTS AND SYSTEMS, 2015, 1 (02)
  • [29] Simulation and characterization of polycrystalline mercuric iodide film detector based on coplanar grid electrode
    Huang, Lu
    Qu, Xingling
    Yang, Weiguang
    Li, Dongmei
    Chen, Yang
    Jin, Jing
    Wang, Linjun
    Zhu, Wenqing
    Ding, Weizhong
    Shi, Weimin
    VACUUM, 2015, 122 : 54 - 58
  • [30] Encoding methods matching the 16×16 pixel CZT detector of a coded aperture gamma camera
    Xiao-Lei Shen
    Pin Gong
    Xiao-Bin Tang
    Rui Zhang
    Jin-Chao Ma
    Nuclear Science and Techniques, 2020, 31 (09) : 84 - 91