Development of an intraoperative gamma camera based on a 256-pixel mercuric iodide detector array

被引:15
|
作者
Patt, BE [1 ]
Tornai, MP [1 ]
Iwanczyk, JS [1 ]
Levin, CS [1 ]
Hoffman, EJ [1 ]
机构
[1] UNIV CALIF LOS ANGELES,SCH MED,DIV NUCL MED & BIOPHYS,DEPT MOL & MED PHARMACOL,LOS ANGELES,CA 90095
基金
美国国家卫生研究院;
关键词
D O I
10.1109/23.596995
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
A 256-element mercuric iodide (HgI2) detector array has been developed which is intended for use as an intraoperative gamma camera (IOGC). The camera is specifically designed for use in imaging gamma-emitting radiopharmaceuticals (such as 99m-Tc labeled Sestamibi) incorporated into brain tumors in the intraoperative surgical environment. The system is intended to improve the success of tumor removal surgeries by allowing more complete removal of subclinical tumor cells without removal of excessive normal tissue. The use of HgI2 detector arrays in this application facilitates construction of an imaging head that is very compact and has a high SNR. The detector is configured as a cross-grid array. Pixel dimensions are 1.25 mm squares separated by 0.25 mm. The overall dimension of the detector is 23.75 mm on a side. The detector thickness is 1 mm which corresponds to over 60% stopping at 140 keV. The array has good uniformity with average energy resolution of 5.2 +/- 2.9 % FWHM at 140 keV (best resolution was 1.9 % FWHM). Response uniformity (+/- sigma) was 7.9 %. A study utilizing realistic tumor phantoms (uptake ratio varied from 2:1 to 100:1) in background (1 mCi/l) was conducted. SNR's for the reasonably achievable uptake ratio of 50:1 were 5.61 sigma with 1 cm of background depth (''normal tissue'') and 2.74 sigma with 4 cm of background for a 6.3 mu l tumor phantom (similar to 270 nCi at the time of the measurement).
引用
收藏
页码:1242 / 1248
页数:7
相关论文
共 50 条
  • [1] Toward a 256-Pixel Array of Gamma-Ray Microcalorimeters for Nuclear-Materials Analysis
    W. B. Doriese
    J. N. Ullom
    J. A. Beall
    W. D. Duncan
    L. Ferreira
    G. C. Hilton
    R. D. Horansky
    K. D. Irwin
    J. A. B. Mates
    C. D. Reintsema
    D. R. Schmidt
    L. R. Vale
    Y. Xu
    B. L. Zink
    M. K. Bacrania
    A. S. Hoover
    C. R. Rudy
    M. W. Rabin
    C. A. Kilbourne
    K. R. Boyce
    L. E. Brown
    J. M. King
    F. S. Porter
    Journal of Low Temperature Physics, 2008, 151 : 754 - 759
  • [2] Toward a 256-pixel array of gamma-ray microcalorimeters for nuclear-materials analysis
    Doriese, W. B.
    Ullom, J. N.
    Beall, J. A.
    Duncan, W. D.
    Ferreira, L.
    Hilton, G. C.
    Horansky, R. D.
    Irwin, K. D.
    Mates, J. A. B.
    Reintsema, C. D.
    Schmidt, D. R.
    Vale, L. R.
    Xu, Y.
    Zink, B. L.
    Bacrania, M. K.
    Hoover, A. S.
    Rudy, C. R.
    Rabin, M. W.
    Kilbourne, C. A.
    Boyce, K. R.
    Brown, L. E.
    King, J. M.
    Porter, F. S.
    JOURNAL OF LOW TEMPERATURE PHYSICS, 2008, 151 (3-4) : 754 - 759
  • [3] 256-pixel CMOS-integrated thermoelectric infrared sensor array
    Schaufelbuehl, A
    Münch, U
    Menolfi, C
    Brand, O
    Paul, O
    Huang, Q
    Baltes, H
    14TH IEEE INTERNATIONAL CONFERENCE ON MICRO ELECTRO MECHANICAL SYSTEMS, TECHNICAL DIGEST, 2001, : 200 - 203
  • [4] DEVELOPMENT OF A MERCURIC IODIDE DETECTOR ARRAY FOR MEDICAL IMAGING APPLICATIONS
    PATT, BE
    IWANCZYK, JS
    TORNAI, MP
    LEVIN, CS
    HOFFMAN, EJ
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1995, 366 (01): : 173 - 182
  • [5] 256 x 256-pixel CMOS digital camera for computer vision with 32 algorithmic ADCs on board
    Simoni, A
    Torelli, G
    Maloberti, F
    Sartori, A
    Gottardi, M
    Gonzo, L
    IEE PROCEEDINGS-CIRCUITS DEVICES AND SYSTEMS, 1999, 146 (04): : 184 - 190
  • [6] Monte Carlo analysis of a mercuric iodide neutron/gamma detector
    Bell, ZW
    West, WG
    Pohl, KR
    van den Berg, L
    2004 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-7, 2004, : 4580 - 4584
  • [7] Monte Carlo analysis of a mercuric iodide neutron/gamma detector
    Bell, ZW
    West, WG
    Pohl, KR
    van den Berg, L
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2005, 52 (05) : 2030 - 2034
  • [8] Achieving 256 x 256-Pixel Color Images by Perovskite-Based Photodetectors Coupled with Algorithms
    Ji, Zhong
    Liu, Yujin
    Yao, Manhong
    Zhang, Zibang
    Zhong, Jingang
    Mai, Wenjie
    ADVANCED FUNCTIONAL MATERIALS, 2021, 31 (37)
  • [9] 256-pixel microcalorimeter array for high-resolution γ-ray spectroscopy of mixed-actinide materials
    Winkler, R.
    Hoover, A. S.
    Rabin, M. W.
    Bennett, D. A.
    Doriese, W. B.
    Fowler, J. W.
    Hays-Wehle, J.
    Horansky, R. D.
    Reintsema, C. D.
    Schmidt, D. R.
    Vale, L. R.
    Ullom, J. N.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2015, 770 : 203 - 210
  • [10] PRELIMINARY STUDIES ON MERCURIC IODIDE SOFT-GAMMA-RAY DETECTOR
    CHUNG, MK
    CHO, SW
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1976, 23 (01) : 112 - 116