Simultaneous analysis method of 89Sr and 90Sr in liquid sample using automated separation system

被引:0
|
作者
Kim, Heewon [1 ]
Lee, Yong-Jin [1 ,2 ]
Kim, Sun-Ha [1 ]
Lee, Jin-Hong [2 ]
Lim, Jong-Myoung [1 ]
Kim, Hyuncheol [1 ]
机构
[1] Korea Atom Energy Res Inst, Environm Radioact Assessment Team, 111 Daedeok Daero 989beon Gil, Daejeon 34057, South Korea
[2] Chung Nam Univ, Environm Engn, 99 Daehak Ro, Daejeo 34134, South Korea
来源
ANALYTICAL SCIENCE AND TECHNOLOGY | 2020年 / 33卷 / 06期
关键词
Sr-89; Sr-90; LSC; liquid sample; automated separation; RAPID-DETERMINATION; RADIOSTRONTIUM; STRONTIUM; CALCIUM;
D O I
10.5806/AST.2020.33.6.274
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
This study described the analytical method for simultaneous determination of Sr-89 and Sr-90 in liquid sample using automated separation system. Radiostrontium in 0.5 kg of liquid sample was concentrated as SrCO3 to reduce the volume of sample, and purified from the sample using Sr-resin 2 mL (BV, Bed volume). The behavior of Sr and interferences such as Ba, Ca and Y were estimated with various flow rate ranging from 1 to 4 mL min(-1). The detailed procedure for the purification of Sr on Sr-resin was presented. The purified radiostronitum was measured in Cerenkov mode and then measured in Scintillation mode by mixing scintillation cocktail. The measured value in both modes were used to calculate the activity of Sr-89 and Sr-90. The performance tests were carried out the lab-control-sample having various activity ratio of between Sr-89 and Sr-90. The recovery of Sr was ranged from 68 to 94 %. The relative bias of Sr-89 activity was ranged from -5 to 20 %, and it was ranged from -10 to 10 % for Sr-90.
引用
收藏
页码:274 / 284
页数:11
相关论文
共 50 条
  • [21] RESOLUTION OF 89SR AND 90SR IN ENVIRONMENTAL MEDIA BY AN INSTRUMENTAL TECHNIQUE
    VELTEN, RJ
    NUCLEAR INSTRUMENTS & METHODS, 1966, 42 (01): : 169 - &
  • [22] A rapid method for simultaneously determining activity of 89Sr and 90Sr in a non-equilibrated 90Sr/90Y system without Cerenkov counting
    Cong Wei
    Journal of Radioanalytical and Nuclear Chemistry, 2024, 333 : 841 - 845
  • [23] A rapid method for simultaneously determining activity of 89Sr and 90Sr in a non-equilibrated 90Sr/90Y system without Cerenkov counting
    Wei, Cong
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2024, 333 (02) : 841 - 845
  • [24] Handling interferences in 89Sr and 90Sr measurements of reactor coolant water: A method based on strontium separation chemistry
    Holmgren, S.
    Tovedal, A.
    Jonsson, S.
    Nygren, U.
    Rameback, H.
    APPLIED RADIATION AND ISOTOPES, 2014, 90 : 94 - 101
  • [25] COMPARISON OF UK AND US EMERGENCY ACTION GUIDES FOR 89SR AND 90SR
    不详
    HEALTH PHYSICS, 1965, 11 (11): : 1242 - +
  • [26] Methodology for determination of 89Sr and 90Sr in radiological emergency: II. Method development and evaluation
    Annika Tovedal
    Ulrika Nygren
    Petra Lagerkvist
    Anna Vesterlund
    Henrik Ramebäck
    Journal of Radioanalytical and Nuclear Chemistry, 2009, 282 : 461 - 466
  • [27] Methodology for determination of 89Sr and 90Sr in radiological emergency: II. Method development and evaluation
    Tovedal, Annika
    Nygren, Ulrika
    Lagerkvist, Petra
    Vesterlund, Anna
    Rameback, Henrik
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2009, 282 (02) : 461 - 466
  • [28] 89Sr样品中90Sr含量的简便测定方法
    张蕾
    何蔚瑜
    沈德群
    曹本红
    核技术, 1999, (08) : 500 - 503
  • [29] Determination of 89Sr and 90Sr from low- and intermediate-level radioactive liquid waste
    Vincze, A
    Solymosi, J
    Ormai, P
    Volent, G
    NUCLEAR PHYSICAL METHODS IN RADIOECOLOGICAL INVESTIGATIONS OF NUCLEAR TEST SITES, 2000, 31 : 145 - 150
  • [30] Rapid determination of 89Sr and 90Sr in radioactive waste using Sr extraction disk and beta-ray spectrometer
    Kameo, Y.
    Katayama, A.
    Fujiwara, A.
    Haraga, T.
    Nakashima, M.
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2007, 274 (01) : 71 - 78