Experimental Demonstration of Decay Heat Removal by Submerged Feeders in a Full-Scale Test Facility of a Natural Circulation Boiling Water Reactor

被引:2
|
作者
Nayak, A. K. [1 ]
Kumar, Mukesh [1 ]
Prasad, Sumit, V [1 ]
Jain, V [1 ]
Chandraker, D. K. [1 ]
机构
[1] Bhabha Atom Res Ctr, Reactor Engn Div, Reactor Design & Dev Grp, Mumbai 400085, Maharashtra, India
来源
JOURNAL OF NUCLEAR ENGINEERING AND RADIATION SCIENCE | 2019年 / 5卷 / 04期
关键词
DESIGN; AHWR;
D O I
10.1115/1.4042852
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
Removal of decay heat with nonavailability of active systems is a safety issue especially during station blackout (SBO) in a light water reactor. Passive systems are being incorporated in the new designs of nuclear reactors for this purpose. Some of the advanced reactors such as Indian advanced heavy water reactor (AHWR) have dedicated isolation condensers (ICs) which are submerged in large water pool called gravity driven water pool (GDWP). These IC's remove decay heat from the core by natural circulation cooling and dissipate it to the GDWP by natural convection. There is a concern that cracks may develop in the GDWP if a large seismic event similar to Fukushima type occurs. In that case, the pool water is lost and it can threaten the core coolability because of loss of heat sink. In AHWR, the cracks in the water pool leads to the relocation of the water of the pool to the reactor cavity. Feeders of AHWR are positioned in the reactor cavity. Thus, the water relocated in the cavity, will eventually submerge the feeders and these submerged feeders have the potential to remove the decay heat of the core. However, the f eeders are located at a lower elevation as compared to the core, and hence, there is concern on the heat removal capability by the submerged feeders by natural convection. To understand this aspect and to establish the core coolability under the above-mentioned conditions, experiments were performed in a full-scale test facility of AHWR. Experiments showed that the decay heat can be safely removed in natural circulation mode of cooling with heat sink located at lower elevation than the heat source.
引用
收藏
页数:7
相关论文
共 50 条
  • [41] CFD analyses of passive decay heat removal for the Very-Small, Long-LIfe, Modular (VSLLIM) reactor by natural circulation of ambient air
    Palomino, Luis M.
    El-Genk, Mohamed S.
    THERMAL SCIENCE AND ENGINEERING PROGRESS, 2019, 11 : 50 - 65
  • [42] Cooldown of a water-cooled reactor during the natural circulation mode using decay heat of the core and a low-power steam turbine
    Yurin, V. E.
    Egorov, A. N.
    Bashlykov, D. O.
    NUCLEAR ENGINEERING AND DESIGN, 2023, 409
  • [43] Effects of decay heat and cooling condition on the reactor pool natural circulation under RVACS operation in a water 2-D slab model
    Lee, Min Ho
    Jerng, Dong Wook
    Bang, In Cheol
    NUCLEAR ENGINEERING AND TECHNOLOGY, 2023, 55 (05) : 1821 - 1829
  • [44] Experimental investigations on decay heat removal in advanced nuclear reactors using single heater rod test facility: Air alone in the annular gap
    Bopche, Santosh B.
    Sridharan, Arunkumar
    EXPERIMENTAL THERMAL AND FLUID SCIENCE, 2010, 34 (08) : 1456 - 1474
  • [45] IETI-3 - AN OUT-OF-PILE FACILITY FOR HEAT TRANSFER TESTS OF FULL SCALE REACTOR POWER CHANNELS COOLED WITH EVAPORATING WATER
    HASSID, A
    RAVETTA, R
    RUBIERA, L
    ENERGIA NUCLEARE, 1970, 17 (06): : 347 - &
  • [46] Full-scale experimental study on the smoke and thermal insulation of a water mist fire extinguishing system in a short road tunnel with natural ventilation
    Kan, Deyuan
    Feng, Shouzhong
    Yan, Zhiguo
    Zhou, Long
    Zhu, Hehua
    TUNNELLING AND UNDERGROUND SPACE TECHNOLOGY, 2025, 158
  • [47] Full-scale modelling of the MNSR reactor to simulate normal operation, transients and reactivity insertion accidents under natural circulation conditions using the thermal hydraulic code ATHLET
    Hainoun, A
    Alissa, S
    NUCLEAR ENGINEERING AND DESIGN, 2005, 235 (01) : 33 - 52
  • [48] Experimental studies and computational benchmark on heavy liquid metal natural circulation in a full height-scale test loop for small modular reactors
    Shin, Yong-Hoon
    Cho, Jaehyun
    Lee, Jueun
    Ju, Heejae
    Sohn, Sungjune
    Kim, Yeji
    Noh, Hyunyub
    Hwang, Il Soon
    NUCLEAR ENGINEERING AND DESIGN, 2017, 316 : 26 - 37
  • [49] Full-scale demonstration of a floating seal for enhanced biological nutrient removal in a sequencing batch reactor establishing chemical-free environment in wastewater treatment at low carbon source availability
    Szombathy, Peter
    Nagy, Kinga K.
    Vertessy, Beata G.
    Jobbagy, Andrea
    ENVIRONMENTAL TECHNOLOGY, 2024, 45 (03) : 381 - 392
  • [50] Experimental Investigations of the Onset and Growth of a Heat-Transfer Crisis in a Full-Scale Cross-Sectional Model FA of the RITM-200 Reactor for Small NPP
    S. M. Dmitriev
    O. B. Samoilov
    A. V. Kupriyanov
    A. B. Osin
    Atomic Energy, 2022, 133 : 30 - 34