SUPERCONDUCTING QUANTUM INTERFERENCE MAGNETOMETER FOR LARGE MULTICHANNEL SYSTEMS WITH LOW CROSSTALK LEVEL

被引:2
|
作者
Vettoliere, A. [1 ]
Granata, C. [1 ]
Ruggiero, B. [1 ]
Russo, M. [1 ]
机构
[1] CNR, Ist Cibernet E Caianiello, I-80078 Pozzuoli Napoli, Italy
来源
关键词
SQUID magnetometer; crosstalk; SQUID multichannel systems; DC SQUID; MAGNETOENCEPHALOGRAPHY;
D O I
10.1142/S021797920905465X
中图分类号
O59 [应用物理学];
学科分类号
摘要
Magnetometers based on Superconducting Quantum Interference Device (SQUID) are widely employed in high sensitivity magnetometry. In particular, new multichannel systems for biomagnetic applications require many sensors which are very close to each other giving the crosstalk disturbance between the neighboring channel. Here, we present experimental results about a fully integrated dc-SQUID magnetometer, based on niobium technology, having a suitable design which allows to reduce crosstalk due to both the feedback coil and wires. The crosstalk level measurements relative to a particular arrangement of sensors are reported. In such configuration, four magnetometers are placed over a square board 30 mm in side with a distance between their sensor centers of 14 mm. The measurements have been performed in a 4 Hecryostatat T = 4:2 K in a flux-locked loop configuration using a readout electronics with a direct coupled scheme. The experimental data have shown a substantial reduction of crosstalk among neighboring sensors with respect to a traditional feedback coil. Furthermore, the field noise measurements have ensured that the new pickup and feedback coils design does not introduce any noise level degradation.
引用
收藏
页码:5759 / 5767
页数:9
相关论文
共 50 条
  • [21] Development of miniature diamond anvil cell for the superconducting quantum interference device magnetometer
    Mito, M. (mitohtap@mbox.nc.kyushu-u.ac.jp), 1600, Japan Society of Applied Physics (40):
  • [22] Biological immunoassay with high Tc superconducting quantum interference device (SQUID) magnetometer
    Enpuku, K
    Minotani, T
    IEICE TRANSACTIONS ON ELECTRONICS, 2001, E84C (01): : 43 - 48
  • [23] A miniature magnetometer based on the superconducting quantum interference device with direct readout electronics
    Polushkin, V
    Wallis, M
    Glowacka, D
    Matthews, A
    Lumley, JM
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1997, 68 (03): : 1461 - 1464
  • [24] An ultra-sensitive and wideband magnetometer based on a superconducting quantum interference device
    Storm, Jan-Hendrik
    Hoemmen, Peter
    Drung, Dietmar
    Koerber, Rainer
    APPLIED PHYSICS LETTERS, 2017, 110 (07)
  • [25] Basic study on multiplexed superconducting quantum interference device for multichannel biomagnetometer
    Kazami, K
    Kawai, J
    Uehara, G
    JAPANESE JOURNAL OF APPLIED PHYSICS PART 2-LETTERS & EXPRESS LETTERS, 1996, 35 (8B): : L1055 - L1058
  • [26] Characterization of directly coupled dual-superconducting quantum interference device magnetometer
    Wu, C. H.
    Chen, J. H.
    Jhan, F. J.
    Jeng, J. T.
    Yang, H. C.
    JOURNAL OF APPLIED PHYSICS, 2008, 104 (07)
  • [27] Development of miniature diamond anvil cell for the superconducting quantum interference device magnetometer
    Mito, M
    Hitaka, M
    Kawae, T
    Takeda, K
    Kitai, T
    Toyoshima, N
    JAPANESE JOURNAL OF APPLIED PHYSICS PART 1-REGULAR PAPERS SHORT NOTES & REVIEW PAPERS, 2001, 40 (11): : 6641 - 6644
  • [28] Experimental study of a hybrid single flux quantum digital superconducting quantum interference device magnetometer
    Reich, Torsten
    Febvre, Pascal
    Ortlepp, Thomas
    Uhlmann, F. Hermann
    Kunert, Juergen
    Stolz, Ronny
    Meyer, Hans-Georg
    JOURNAL OF APPLIED PHYSICS, 2008, 104 (02)
  • [29] Experimental study of a hybrid single flux quantum digital superconducting quantum interference device magnetometer
    Reich, Torsten
    Febvre, Pascal
    Ortlepp, Thomas
    Uhlmann, F. Hermann
    Kunert, Juergen
    Stolz, Ronny
    Meyer, Hans-Georg
    Journal of Applied Physics, 2008, 104 (02):
  • [30] Low-frequency noise of high Tc superconducting quantum interference device (SQUID) magnetometer fabricated on bicrystal substrate
    Minotani, Tadashi
    Hotta, Masahiro
    Enpuku, Keiji
    Japanese Journal of Applied Physics, Part 2: Letters, 2000, 39 (5 A):