SUPERCONDUCTING QUANTUM INTERFERENCE MAGNETOMETER FOR LARGE MULTICHANNEL SYSTEMS WITH LOW CROSSTALK LEVEL

被引:2
|
作者
Vettoliere, A. [1 ]
Granata, C. [1 ]
Ruggiero, B. [1 ]
Russo, M. [1 ]
机构
[1] CNR, Ist Cibernet E Caianiello, I-80078 Pozzuoli Napoli, Italy
来源
关键词
SQUID magnetometer; crosstalk; SQUID multichannel systems; DC SQUID; MAGNETOENCEPHALOGRAPHY;
D O I
10.1142/S021797920905465X
中图分类号
O59 [应用物理学];
学科分类号
摘要
Magnetometers based on Superconducting Quantum Interference Device (SQUID) are widely employed in high sensitivity magnetometry. In particular, new multichannel systems for biomagnetic applications require many sensors which are very close to each other giving the crosstalk disturbance between the neighboring channel. Here, we present experimental results about a fully integrated dc-SQUID magnetometer, based on niobium technology, having a suitable design which allows to reduce crosstalk due to both the feedback coil and wires. The crosstalk level measurements relative to a particular arrangement of sensors are reported. In such configuration, four magnetometers are placed over a square board 30 mm in side with a distance between their sensor centers of 14 mm. The measurements have been performed in a 4 Hecryostatat T = 4:2 K in a flux-locked loop configuration using a readout electronics with a direct coupled scheme. The experimental data have shown a substantial reduction of crosstalk among neighboring sensors with respect to a traditional feedback coil. Furthermore, the field noise measurements have ensured that the new pickup and feedback coils design does not introduce any noise level degradation.
引用
收藏
页码:5759 / 5767
页数:9
相关论文
共 50 条
  • [1] MEASUREMENT OF ELECTROCHEMICAL CORROSION CURRENTS USING A MULTICHANNEL SUPERCONDUCTING QUANTUM INTERFERENCE DEVICE MAGNETOMETER
    HIBBS, AD
    JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 1992, 139 (09) : 2447 - 2457
  • [2] Large inductance superconducting quantum interference device magnetometer for magnetoencephalography measurement
    Ahmad, RS
    Kubo, M
    Hirata, Y
    Kuriki, S
    Nakayama, S
    JAPANESE JOURNAL OF APPLIED PHYSICS PART 1-REGULAR PAPERS BRIEF COMMUNICATIONS & REVIEW PAPERS, 1997, 36 (11): : 6737 - 6741
  • [3] Large inductance superconducting quantum interference device magnetometer for magnetoencephalography measurement
    Ahmad, Rashdi Shah
    Kubo, Masateru
    Hirata, Yoshihiro
    Kuriki, Shinya
    Nakayama, Satoshi
    Japanese Journal of Applied Physics, Part 1: Regular Papers & Short Notes & Review Papers, 1997, 36 (11): : 6737 - 6741
  • [4] A low field superconducting quantum interference device magnetometer for dynamic measurements
    Magnusson, J
    Djurberg, C
    Granberg, P
    Nordblad, P
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1997, 68 (10): : 3761 - 3765
  • [5] Calibration of a superconducting quantum interference device magnetometer
    Koyano, T
    JAPANESE JOURNAL OF APPLIED PHYSICS PART 1-REGULAR PAPERS SHORT NOTES & REVIEW PAPERS, 2004, 43 (10): : 7322 - 7323
  • [6] Calibration of a superconducting quantum interference device magnetometer
    Koyano, T., 1600, Japan Society of Applied Physics (43):
  • [7] Improved superconducting quantum interference device magnetometer for low cross talk operation
    Granata, C.
    Vettoliere, A.
    Russo, M.
    APPLIED PHYSICS LETTERS, 2006, 88 (21)
  • [8] Design and fabrication of low-noise superconducting quantum interference device magnetometer
    Han Hao-Xuan
    Zhang Guo-Feng
    Zhang Xue
    Liang Tian-Tian
    Ying Li-Liang
    Wang Yong-Liang
    Peng Wei
    Wang Zhen
    ACTA PHYSICA SINICA, 2019, 68 (13)
  • [9] QUANTUM INTERFERENCE IN MULTICHANNEL SYSTEMS
    JOE, YS
    KHATUN, M
    COSBY, RM
    JOURNAL OF APPLIED PHYSICS, 1995, 78 (04) : 2863 - 2865