摘要
Glued-in rods (GiR), which consist of rods glued into structural elements of wood, or engineered wood products, share the manufacturing quality concerns associated to adhesively bonded joints in general. Because of the difficulties associated with the bonding process, it is often argued within the timber engineering community that under the specific conditions prevailing in construction sites, it is not possible to meet the high-quality requirements for bonded joints typically encountered in other industries. The present study presents experimental evidence gathered on 240 individual probes in which the effect of several different types of defects (excessive wood moisture content, wood chips not removed from the borehole, simulated air inclusions by mixing polystyrene spheres, oil contaminated rods, and corroded rod) was investigated with threaded rods glued into beech spruce glued laminated timber (GLT) and beech laminated veneer lumber (LVL) using four adhesives (including 2K-epoxies and a 2K-polyurethane). Results were analysed by means of an analysis of variance (ANOVA). The findings showed that glued-in rods represent a relatively robust class of adhesively bonded joints, as the majority of defects types could not be distinguished on statistical ground from the reference sets, with the notable exception of air voids leading to a significant decrease of joint capacity. (C) 2019 Elsevier Ltd. All rights reserved.
引用
收藏
页码:200 / 211
页数:12
相关论文
共 50 条
  • [41] Analytical study and finite element modelling of timber connections with glued-in rods in bending
    Xu, B. H.
    Bouchair, A.
    Racher, P.
    CONSTRUCTION AND BUILDING MATERIALS, 2012, 34 : 337 - 345
  • [42] Influence of elevated temperature on glued-in steel rods for timber elements
    Di Maria, Valentina
    D'Andria, Luca
    Muciaccia, Giovanni
    Ianakiev, Anton
    CONSTRUCTION AND BUILDING MATERIALS, 2017, 147 : 457 - 465
  • [43] Mechanical performance of glued-in rod glulam beam to column moment connection: An experimental study
    Navaratnam, Satheeskumar
    Thamboo, Julian
    Ponnampalam, Thusiyanthan
    Venkatesan, Srikanth
    Chong, Kim Beng
    JOURNAL OF BUILDING ENGINEERING, 2022, 50
  • [44] Geometric parameters which affect the short term resistance of an axially loaded glued-in rod
    Gardelle, Vincent
    Morlier, Pierre
    MATERIALS AND STRUCTURES, 2007, 40 (01) : 127 - 138
  • [45] Geometric parameters which affect the short term resistance of an axially loaded glued-in rod
    Vincent Gardelle
    Pierre Morlier
    Materials and Structures, 2007, 40 : 127 - 138
  • [46] Load-Carrying Capacity and Stiffness of Softwood Wooden Dowel Connections
    Frontini, Filippo
    Siem, Jan
    Renmaelmo, Roald
    INTERNATIONAL JOURNAL OF ARCHITECTURAL HERITAGE, 2020, 14 (03) : 376 - 397
  • [47] Analysis of the stiffness and load-bearing capacity of glued laminated timber beams reinforced with strands
    Sardiko, R.
    Rocens, K.
    Iejavs, J.
    Jakovlevs, V.
    Ziverts, K.
    3RD INTERNATIONAL CONFERENCE ON INNOVATIVE MATERIALS, STRUCTURES AND TECHNOLOGIES (IMST 2017), 2017, 251
  • [48] Influence of glued-in reinforcement profiles on the thermal characteristics of wooden window profiles
    Subic, Barbara
    Ugovsek, Ales
    Starman, Nejc
    Tatic, Uros
    Kovacic, Aljaz
    Fajdiga, Gorazd
    ECF22 - LOADING AND ENVIRONMENTAL EFFECTS ON STRUCTURAL INTEGRITY, 2018, 13 : 503 - 510
  • [49] Experimental investigation on the behavior of glued-in rod joints in timber beams subjected to monotonic and cyclic loading
    Gattesco, Natalino
    Gubana, Alessandra
    Buttazzi, Manuela
    Melotto, Massimo
    ENGINEERING STRUCTURES, 2017, 147 : 372 - 384
  • [50] Numerical modeling investigation of cross-laminated timber connections consisting of multiple glued-in rods
    Shirmohammadli, Younes
    Hashemi, Ashkan
    Masoudnia, Reza
    Quenneville, Pierre
    STRUCTURES, 2023, 53 : 491 - 500