Hyperbaric oxygen for idiopathic sudden sensorineural hearing loss and tinnitus

被引:27
|
作者
Bennett, M. H.
Kertesz, T.
Yeung, P.
机构
[1] Diving and Hyperbaric Medicine, Prince of Wales Hospital, Randwick, NSW 2031, Barker Street
关键词
D O I
10.1002/14651858.CD004739.pub3
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background Idiopathic sudden sensorineural hearing loss (ISSHL) with or without tinnitus is common and presents a health problem with significant effect on quality of life. Hyperbaric oxygen therapy (HBOT) may improve oxygen supply to the inner ear and, it is postulated, may result in an improvement in hearing and/or a reduction in the intensity of tinnitus. Objectives To assess the benefits and harms of HBOT for treating ISSHL and/or tinnitus. Search strategy We initially searched in June 2004 and repeated the search in June 2006. Our search included the Cochrane Ear, Nose and Throat Disorders Group Trials Register, the Cochrane Central Register of Controlled Trials (CENTRAL) (The Cochrane Library, Issue 2 2006), MEDLINE (1951 to 2006), EMBASE (1974 to 2006), CINAHL, Database of Randomised Trials in Hyperbaric Medicine (DORCTHIM), AMED, LILACS, KOREAMED, INDMED, National Research Register (NRR), CSA, ISI PROCEEDINGS and ZETOC. Selection criteria Randomised studies comparing the effect on ISSHL and/or tinnitus of therapeutic regimens which include HBOT with those that exclude HBOT. Data collection and analysis Three authors independently evaluated the quality of the relevant trials using the validated Oxford-Scale (Jadad 1996) and extracted the data from the included trials. Main results Six trials contributed to this review (308 subjects). Pooled data from two trials involving 114 patients did not show any significant improvement in the chance of a 50% increase in hearing threshold on Pure Tone Average (PTA) when HBOT was used (relative risk [RR] with HBOT 1.53, 95% CI 0.85 to 2.78, P = 0.16), but did show a significantly increased chance of a 25% increase in PTA (RR 1.39, 95% CI 1.05 to 1.84, P = 0.02). There was a 22% greater chance of improvement with HBOT, and the number needed to treat (NNT) to achieve one extra good outcome was five (95% CI 3 to 20). A single trial involving 50 subjects also suggested significantly more improvement in the mean PTA threshold with HBOT, expressed as a percentage of baseline (WMD 37%, 95% CI 22% to 53%, P < 0.001). The significance of any improvement following HBOT in a subjective rating of tinnitus could not be assessed due to poor reporting. There were no significant improvements in hearing or tinnitus reported in the single study to examine chronic presentation (six months) of ISSHL and/or tinnitus. Authors' conclusions For people with early presentation of ISSHL, the application of HBOT significantly improved hearing loss, but the clinical significance of the level of improvement is not clear. We could not assess the effect of HBOT on tinnitus by pooled data analysis. The routine application of HBOT to these patients cannot be justified from this review. In view of the modest number of patients, methodological shortcomings and poor reporting, this result should be interpreted cautiously, and an appropriately powered trial of high methodological rigour is justified to define those patients (if any) who can be expected to derive most benefit from HBOT. There is no evidence of a beneficial effect of HBOT on chronic presentation of ISSHL and/or tinnitus and we do not recommend use of HBOT for this purpose based on the single study available.
引用
收藏
页数:24
相关论文
共 50 条
  • [41] Prostaglandin E1 in combination with hyperbaric oxygen therapy for idiopathic sudden sensorineural hearing loss
    Suzuki, Hideaki
    Fujimura, Takeyuki
    Ikeda, Katsuhisa
    Shiomori, Teruo
    Udaka, Tsuyoshi
    Ohbuchi, Toyoaki
    Nagatani, Gunji
    ACTA OTO-LARYNGOLOGICA, 2008, 128 (01) : 61 - 65
  • [42] Efficacy and Prognostic Factors of Combined Hyperbaric Oxygen Therapy in Patients With Idiopathic Sudden Sensorineural Hearing Loss
    Wang, Yong
    Gao, Yali
    Wang, Boxuan
    Chen, Liyan
    Zhang, Xiaoxiao
    AMERICAN JOURNAL OF AUDIOLOGY, 2019, 28 (01) : 95 - 100
  • [43] Prognostic Value of Early Treatment Response in Idiopathic Sudden Sensorineural Hearing Loss Treated with Hyperbaric Oxygen
    Sevil, Ergun
    Cebi, Gamze
    B-ENT, 2024, 20 (03)
  • [44] Characteristics and Spontaneous Recovery of Tinnitus Related to Idiopathic Sudden Sensorineural Hearing Loss
    Muehlmeier, Guido
    Baguley, David
    Cox, Tony
    Suckfuell, Markus
    Meyer, Thomas
    OTOLOGY & NEUROTOLOGY, 2016, 37 (06) : 634 - 641
  • [45] The therapeutic effect of hyperbaric oxygen therapy in patients with severe to profound idiopathic sudden sensorineural hearing loss
    Choi, Yeso
    Han, Sung Jun
    Kim, Sung Kyun
    Hong, Seok Min
    SCIENTIFIC REPORTS, 2024, 14 (01)
  • [46] The therapeutic effect of hyperbaric oxygen therapy in patients with severe to profound idiopathic sudden sensorineural hearing loss
    Yeso Choi
    Sung Jun Han
    Sung Kyun Kim
    Seok Min Hong
    Scientific Reports, 14
  • [47] Extensive Heterogeneity in the Meta-analysis of Hyperbaric Oxygen Therapy for Idiopathic Sudden Sensorineural Hearing Loss
    Lammers, Marc Jan-Willem
    Lea, Jane
    Westerberg, Brian D.
    JAMA OTOLARYNGOLOGY-HEAD & NECK SURGERY, 2019, 145 (05) : 483 - 484
  • [48] Prognostic factors for idiopathic sudden sensorineural hearing loss treated with hyperbaric oxygen therapy and intravenous steroids
    Hosokawa, S.
    Sugiyama, K.
    Takahashi, G.
    Takebayashi, S.
    Mineta, H.
    JOURNAL OF LARYNGOLOGY AND OTOLOGY, 2017, 131 (01): : 77 - 82
  • [49] Efficacy of intratympanic steroid administration on idiopathic sudden sensorineural hearing loss in comparison with hyperbaric oxygen therapy
    Suzuki, Hideaki
    Hashida, Koichi
    Khac-Hung Nguyen
    Hohchi, Nobusuke
    Katoh, Akiko
    Koizumi, Hiroki
    Ohbuchi, Toyoaki
    LARYNGOSCOPE, 2012, 122 (05): : 1154 - 1157
  • [50] Idiopathic sudden sensorineural hearing loss
    Rauch, Steven D.
    NEW ENGLAND JOURNAL OF MEDICINE, 2008, 359 (08): : 833 - 840